TR-33 TR-34 TR-35 Trillium Rhino User's Manual - Frame Grabbers

TR-33 TR-34 TR-35 Trillium Rhino User's Manual - Frame Grabbers TR-33 TR-34 TR-35 Trillium Rhino User's Manual - Frame Grabbers

10.05.2014 Views

68 Trillium User’s Manual 03-32-10119-03 DALSA

Trillium User’s Manual 69 TRILLIUM USER'S MANUAL Appendix E: Dark Offset De-rating Curve D1. Overview At high temperatures and low line rates, the increase in CCE by the IL-P3 sensor results in large dark offsets, caused by the amplification of temperature generated dark signal integrated over long periods. This effect has an impact on the ability of the Trillium camera to correctly calibrate itself. The plots below detail the offset characteristics and associated limits for successful calibration. The first plot shows the limit for cc3 being able to calibrate the camera (without a dark reference) and meet the calibration accuracy specifications: Blue Channel I nt egration Time Pl ots of O ffset vs Temper ature DN Offset 20 15 10 5 0 0 10 20 30 40 50 Te mp. C 3333us ec 2000us ec 1000us ec 500usec 250usec 143usec 90.9us ec "cc 3" Limit Integration Time De-rating Plots for the cc3 Calibration Mode, Typical Gains Set to 2 DALSA 03-32-10119-03

68 <strong>Trillium</strong> User’s <strong>Manual</strong><br />

03-32-10119-03 DALSA

Hooray! Your file is uploaded and ready to be published.