44 Trillium User’s Manual • Ensure that all cable shields have 360° electrical connection to the connector. • Electrically connect camera mount to the metal camera support structure. EMC Test Setup for CE Compliance Testing Camera electrically connected to test jig via camera mounting Test camera Iris Cable Lens Cable details • Data cable, 3M #3600B/68 • Power cable, Unitrek #178-1187-66 • RS232 cable, Alpha #3469C • Control cable, 3M #3600B/14 CRT All cables use double shielding, 100% foil, 80% braid minimum (samples available in starter kit) Keyboard and Mouse 41" EXsync/PR Generator Welded aluminum frame PC Power Supply 03-32-10119-03 DALSA

Trillium User’s Manual 45 C HAPTER 5 5.0 Troubleshooting The information in this chapter can help you solve problems that may occur during the setup of your camera. Remember that the camera is part of the entire acquisition system. You may have to troubleshoot any or all of the following: • power supplies • frame grabber hardware & software • light sources • operating environment 5.1 Diagnostic Tools • cabling • host computer • optics • encoder The Trillium has a range of very useful diagnostic capabilities, including the following: • On-camera LED status code indicator. • With a 12 – 15V power supply and a RS232 connection, you can capture reference data without a frame grabber. • The camera can output a test pattern for data path/acquisition system debugging. • Internal diagnostics to verify power, temperature and timing. DALSA 03-32-10119-03

<strong>Trillium</strong> User’s <strong>Manual</strong> 45<br />

C HAPTER 5<br />

5.0 Troubleshooting<br />

The information in this chapter can help you solve problems that may occur<br />

during the setup of your camera. Remember that the camera is part of the entire<br />

acquisition system. You may have to troubleshoot any or all of the following:<br />

• power supplies<br />

• frame grabber hardware & software<br />

• light sources<br />

• operating environment<br />

5.1 Diagnostic Tools<br />

• cabling<br />

• host computer<br />

• optics<br />

• encoder<br />

The <strong>Trillium</strong> has a range of very useful diagnostic capabilities, including the<br />

following:<br />

• On-camera LED status code indicator.<br />

• With a 12 – 15V power supply and a RS232 connection, you can capture<br />

reference data without a frame grabber.<br />

• The camera can output a test pattern for data path/acquisition system<br />

debugging.<br />

• Internal diagnostics to verify power, temperature and timing.<br />

DALSA 03-32-10119-03