<strong>Trillium</strong> User’s <strong>Manual</strong> 23<br />
Status Code<br />
Explanation<br />
3 Unable to program internal FPGAs. Please report this error code to<br />
DALSA.<br />
4 Validation error programming flash memory. Please report this<br />
error code to DALSA.<br />
5 One or more of the required supply voltages is out of specification.<br />
Please report this error code to DALSA.<br />
6 The camera temperature is outside the valid operating range.<br />
7 The camera memory check failed. Please report this error code to<br />
DALSA.<br />
8 The camera flash memory check failed. Please report this error<br />
code to DALSA.<br />
9 All other failure codes. Detailed in Appendix C.<br />
Notes: Error codes will only be cleared after the error message has been<br />
transmitted through the serial port.<br />
3.4 Setting Line Rate (EXSYNC)<br />
i<br />
All commands<br />
have short<br />
forms. See<br />
Appendix C for<br />
the complete<br />
syntax and<br />
command<br />
reference.<br />
The camera’s line rate (synchronization) generated internally or input from a<br />
frame grabber/host system. The source is selected using the set_sync_mode<br />
mode or ssm mode command through the serial port (see Appendix C for more<br />
details on serial commands, modes, syntax, etc.). When using internally<br />
generated sync, the frequency can be programmed using the commands<br />
set_sync_frequency frequency or ssf frequency, where frequency is<br />
a floating-point number in Hz between 300 and the specified maximum line rate.<br />
For external sync, the control signal EXSYNC determines line rate. See page 17<br />
and section 2.9 Timing.<br />