20 <strong>Trillium</strong> User’s <strong>Manual</strong><br />
Symbol Parameter Units Min. Nom. Max. Notes<br />
t str<br />
S<strong>TR</strong>OBE period ns 40 1<br />
t s<br />
LVAL/Data setup to S<strong>TR</strong>OBE rising edge ns 28 31<br />
t h<br />
LVAL/Data hold from S<strong>TR</strong>OBE rising edge ns 6 9<br />
t ex<br />
EXSYNC period 1K<br />
2K<br />
ms 0.0476<br />
0.0909<br />
3.<strong>33</strong><br />
3.<strong>33</strong><br />
t exh<br />
EXSYNC high duration<br />
% of t ex<br />
2 95 2<br />
t exlval<br />
EXSYNC falling edge to LVAL rising edge µs 2.56 2.76 4<br />
t lval<br />
LVAL high duration 1K<br />
2K<br />
µs 40.96<br />
81.92<br />
t expr<br />
EXSYNC falling edge to PR falling edge hold µs 2<br />
t prh<br />
PR high duration<br />
% of t ex<br />
2 95 5<br />
Notes on Timing<br />
1. Fixed by internal oscillator.<br />
2. High duration determines CCD integration time with EXSYNC in level mode.<br />
3. t exlval will jitter by 20ns due to the synchronization of EXSYNC with<br />
internal camera timing.<br />
4. High duration determines CCD integration time with PRIN in edge mode.<br />
2.10 LED Status Codes<br />
t prh will jitter by 40ns due to the synchronization of EXSYNC with internal<br />
camera timing.<br />
See section 3.3.<br />