20 <strong>Trillium</strong> User’s <strong>Manual</strong><br />

Symbol Parameter Units Min. Nom. Max. Notes<br />

t str<br />

S<strong>TR</strong>OBE period ns 40 1<br />

t s<br />

LVAL/Data setup to S<strong>TR</strong>OBE rising edge ns 28 31<br />

t h<br />

LVAL/Data hold from S<strong>TR</strong>OBE rising edge ns 6 9<br />

t ex<br />

EXSYNC period 1K<br />

2K<br />

ms 0.0476<br />

0.0909<br />

3.<strong>33</strong><br />

3.<strong>33</strong><br />

t exh<br />

EXSYNC high duration<br />

% of t ex<br />

2 95 2<br />

t exlval<br />

EXSYNC falling edge to LVAL rising edge µs 2.56 2.76 4<br />

t lval<br />

LVAL high duration 1K<br />

2K<br />

µs 40.96<br />

81.92<br />

t expr<br />

EXSYNC falling edge to PR falling edge hold µs 2<br />

t prh<br />

PR high duration<br />

% of t ex<br />

2 95 5<br />

Notes on Timing<br />

1. Fixed by internal oscillator.<br />

2. High duration determines CCD integration time with EXSYNC in level mode.<br />

3. t exlval will jitter by 20ns due to the synchronization of EXSYNC with<br />

internal camera timing.<br />

4. High duration determines CCD integration time with PRIN in edge mode.<br />

2.10 LED Status Codes<br />

t prh will jitter by 40ns due to the synchronization of EXSYNC with internal<br />

camera timing.<br />

See section 3.3.<br />

03-32-10119-03 DALSA