SUBCON-PLUS-PROFIB…<br />
3.3 Structure<br />
Figure 3<br />
Structure<br />
3.4 Connection<br />
Stripping<br />
Figure 4<br />
!<br />
9 1<br />
7<br />
8<br />
<br />
Stripping<br />
2<br />
34<br />
5<br />
The following stripping tools are re<strong>com</strong>mended for fast and<br />
easy stripping:<br />
PSM-STRIP-FC/PROFIB (Order No. 2744623) and<br />
QUICK-WIREFOX 6 (Order No. 1204384).<br />
6<br />
$<br />
$ &<br />
24 mm<br />
! <br />
6 13 5<br />
1 Upper housing part<br />
2 Slide switch<br />
3 Connection block for in<strong>com</strong>ing bus<br />
4 Connection block for outgoing bus<br />
5 Mounting screws<br />
6 Lower housing part<br />
7 Strain relief<br />
8 PG connection (SUBCON-PLUS-PROFIB/PG/SC 2<br />
only)<br />
9 Housing screws<br />
Cable Entry<br />
SUBCON-PLUS-PROFIB/SC 2 and SUBCON-PLUS-<br />
PROFIB/PG/SC 2 connectors provide the option of cable<br />
entry from the left or from the right. Upon delivery, the<br />
connector is assembled for cable entry from the left.<br />
To ensure reliable operation, observe the<br />
re<strong>com</strong>mended stripping lengths shown in<br />
Figure 4.<br />
Connection with Cable Entry from the Left<br />
• Strip the conductors as shown in Figure 4.<br />
• Unscrew the housing screws and lift off the upper<br />
housing part.<br />
• Screw the stripped conductors in the corresponding<br />
contacts of the connection block.<br />
• Always connect the in<strong>com</strong>ing bus cable (BUS IN) to<br />
terminal connections 1A/1B (even at the start of the bus<br />
system).<br />
• Always connect the outgoing bus cable (BUS OUT) to<br />
terminal connections 2A/2B.<br />
When doing so, take into account the color-coding of<br />
the connection terminals.<br />
• To finish, mount the upper housing part and tighten the<br />
screws. This provides the strain relief for the bus cable.<br />
online<strong>com</strong>ponents.<strong>com</strong><br />
Figure 5<br />
Connection with cable entry from the left<br />
101610_en_03 PHOENIX CONTACT 4