<strong>UM</strong> <strong>EN</strong> <strong>FLX</strong> <strong>ASI</strong> <strong>SYS</strong> <strong>PRO</strong> <strong>INST</strong><br />

7.3 Configuring the Master<br />

To operate and monitor the AS-i system, the AS-i master constantly <strong>com</strong>pares the actual<br />

status of all slaves with the desired status. Therefore the AS-i master must be informed once<br />

of the desired status of the system during AS-i system startup; this is referred to as the<br />

master configuration process.<br />

In the simplest case, the network at the time of startup can be configured as the desired<br />

configuration.<br />

For additional information, please refer to the user manuals:<br />

Configuring and Installing the AS-Interface Gateway for Inline,<br />

<strong>UM</strong> <strong>EN</strong> <strong>ASI</strong> MA IL UNI, Order No. 2699668<br />

AS-i Gateways for <strong>PRO</strong>FIBUS, <strong>UM</strong> <strong>EN</strong> <strong>FLX</strong> <strong>ASI</strong> MA PB SF/EF<br />

7.4 Operation<br />

The AS-i master carries out system diagnostics continuously during operation. Errors in the<br />

system configuration are displayed immediately together with the corresponding slave<br />

address.<br />

To this end, AS-i masters have LED indicators and displays. This means that it is<br />

immediately clear whether an error has occurred and where the error is located in the<br />

system.<br />

In the event that a slave device fails, only the affected device has to be replaced. This<br />

means that the system can continue operating. The replacement device is automatically<br />

started up using the correct <strong>com</strong>munication address, without having to restart the system.<br />

online<strong>com</strong>ponents.<strong>com</strong><br />

PHO<strong>EN</strong>IX CONTACT 09/2009<br />

7-2 PHO<strong>EN</strong>IX CONTACT 7513_en_01