<strong>UM</strong> <strong>EN</strong> <strong>FLX</strong> <strong>ASI</strong> <strong>SYS</strong> <strong>PRO</strong> <strong>INST</strong><br />

4.2.5 Connecting AS-Interface and the Auxiliary Voltage AUX to<br />

M8 Devices<br />

For Fieldline Extension AS-i M8 devices, the AS-i bus and the power supply are connected<br />

via an M12 female connector. Fieldline Extension AS-i output devices also require the<br />

auxiliary voltage AUX, which is likewise connected via this M12 female connector.<br />

Connection<br />

All supply voltages are connected via an M12 connector.<br />

4.2.6 Pin Assignment of the AS-i Connection<br />

Figure 4-22<br />

Pin assignment of the AS-i connection<br />

Pin AS-i and AUX<br />

1 AS-i +<br />

2 AUX-<br />

3 AS-i -<br />

4 AUX+<br />