06.05.2014 Views

UM EN FLX ASI SYS PRO INST - Onlinecomponents.com

UM EN FLX ASI SYS PRO INST - Onlinecomponents.com

UM EN FLX ASI SYS PRO INST - Onlinecomponents.com

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

AS-Interface Masters/Gateways<br />

2.2.2 Housing dimensions<br />

45<br />

44,33<br />

Connecting to<br />

<strong>PRO</strong>FIBUS DP<br />

<strong>PRO</strong>FIBUS DP slave<br />

AS-i master<br />

Startup<br />

120<br />

Figure 2-13<br />

2.2.3 Function<br />

7513A041<br />

Housing dimensions of the <strong>FLX</strong> <strong>ASI</strong> MA PB SF master in mm<br />

The AS-i master (gateway) establishes the connection between <strong>PRO</strong>FIBUS DP and the AS-<br />

Interface system. The primary task of the AS-i master is to transmit bits from the <strong>PRO</strong>FIBUS<br />

DP to the AS-i slaves (actuators) and bits from AS-i (sensors) to the <strong>PRO</strong>FIBUS DP.<br />

On one side, the AS-i master is controlled by the <strong>PRO</strong>FIBUS master, i.e., it represents a<br />

<strong>PRO</strong>FIBUS DPslave.<br />

On the other side, it is the AS-i master, i.e., it monitors the connected AS-i system<br />

andcontrols all processes on it. All AS-i functions can be called via <strong>PRO</strong>FIBUS DP,<br />

see "AS-i Fault Detector" on page 2-17.<br />

A device database file (GSD) is supplied with the devices, which enables the easy startupof<br />

the AS-i master for <strong>PRO</strong>FIBUS DP. A device database file (GSD) is supplied with the<br />

devices, which enables the easy startup of the AS-i master for <strong>PRO</strong>FIBUS DP. It is<br />

necessary to link a corresponding parameterization/programming software to a device<br />

description file (GSD) to start up AS-i masters. It can be downloaded free of charge at<br />

www.phoenixcontact.net/download.<br />

By default, the device is set to <strong>PRO</strong>FIBUS address 3. The <strong>PRO</strong>FIBUS address can be<br />

modified with two buttons, the three-digit display and the LEDs directly at the device. A<br />

detailed description can be found in the "AS-i-Gateways for <strong>PRO</strong>FIBUS" user manual,<br />

<strong>UM</strong> <strong>EN</strong> <strong>FLX</strong> <strong>ASI</strong> MA PB SF/EF.<br />

online<strong>com</strong>ponents.<strong>com</strong><br />

Configuration<br />

If no PC is available, startup, troubleshooting, and configuration on the AS-i system canalso<br />

be carried out directly on the device using the two buttons, the three-digit display, and the<br />

LEDs. This also includes the addressing of the connected slaves in your AS-i network.<br />

7513_en_01 PHO<strong>EN</strong>IX CONTACT 2-11