6. Fault rectification by the user<br />

Fault Info Rectification<br />

No hot water. No voltage. heck fuses in the house installation.<br />

No flow rate.<br />

Dirt or limescale in the perlators in the<br />

fittings or shower heads.<br />

Clean and/or descale the outlet fittings.<br />

Service symbol<br />

Defect symbol<br />

appears.<br />

flashing.<br />

Water heating continues<br />

(see Table 3).<br />

No water heating<br />

(see Table 3).<br />

Service/maintenance is required.<br />

Corrective maintenance urgently required;<br />

inform qualified installer.<br />

Table 2<br />

7. Fault rectification by the qualified installer<br />

Fault / defect code / Info Possible cause / defect Rectification<br />

No display in the control panel. No voltage.<br />

Restore voltage supply.<br />

Service symbol.<br />

No connection to the control unit.<br />

Control unit defective.<br />

Water heating continues.Maintenance<br />

requirement.<br />

Check that connector „X2“ is correctly<br />

fitted H .<br />

Check control unit (20) and if necessary<br />

replace.<br />

Service code enquiry.<br />

Service / maintenance required.<br />

Code Continuous display -<br />

setpoint temperature.<br />

Code Continuous display -<br />

outlet temperature.<br />

Temperature sensor fault.<br />

Temperature sensor fault.<br />

Check that connector „X10“ is correctly<br />

fitted L . Inspect temperature sensor.<br />

Check that connector „X10“ is correctly<br />

fitted L . Inspect temperature sensor.<br />

Code<br />

No anode protection.<br />

Parasitic current anode fault.<br />

Check that connector „X7“ is correctly<br />

fitted L . Check parasitic current anode and<br />

wiring.<br />

Code<br />

Last preset setpoint values<br />

active. Possibly continuous<br />

display of .<br />

Communication fault with electronic<br />

„regulator“ and „control unit“ modules.<br />

Check that connector „X2“ is correctly<br />

fitted on both modules H .<br />

Check connection cable and modules.<br />

Defect symbol >> flashing.<br />

No water heating.<br />

Defect code enquiry.<br />

Corrective maintenance urgently required!<br />

Code Continuous display -<br />

setpoint temperature.<br />

Temperature sensor defective.<br />

Check that connector „X10“ is correctly<br />

fitted L . Inspect temperature sensor.<br />

Code<br />

No display of heating<br />

element symbol.<br />

Safety thermal cut-out (STB) actuated.<br />

Ursache beheben und entriegeln; STB kontrollieren<br />

ggf. austauschen.<br />

Heating element defective.<br />

Rectify cause and unlock; inspect STB and if<br />

necessary replace.<br />

Code<br />

Running dry protection.<br />

No water in the reservoir.<br />

Fill the reservoir with water.<br />

No anode current.<br />

Check that connector „X7“ is correctly<br />

fitted L . Inspect parasitic current anode<br />

and wiring.<br />

Code<br />

Relay defective.<br />

Replace regulator electronic module (22).<br />

Table 3<br />