KE-FG-D01VNN0500TSP - Official Electronic
KE-FG-D01VNN0500TSP - Official Electronic KE-FG-D01VNN0500TSP - Official Electronic
- Page 3 and 4: EMI SHIELDING FERRITE FILTERING SPL
- Page 5 and 6: FILTERING SOLVING EMI PROBLEMS IN D
- Page 7 and 8: FILTERING SPLIT FERRITES FOR ROUND
- Page 9 and 10: FILTERING SPLIT FERRITES FOR ROUND
- Page 11 and 12: FILTERING FLAT CABLE FERRITES Featu
- Page 13 and 14: FILTERING FLAT CABLE FERRITES Featu
- Page 15 and 16: FILTERING SLIM CORE Features Ultra
- Page 17 and 18: FILTERING FLAT CABLE FERRITES Mount
- Page 19 and 20: FILTERING FLAT CABLE FERRITES Featu
- Page 21 and 22: FILTERING ROUND CABLE FERRITES Feat
- Page 23 and 24: FILTERING ROUND CABLE FERRITES Feat
- Page 25 and 26: FILTERING ROUND CABLE FERRITES FILT
- Page 27 and 28: FILTERING ROUND CABLE FERRITES FILT
- Page 29 and 30: FILTERING FINEMET CORE (F) Features
- Page 31 and 32: FILTERING ROUND CABLE FERRITES Feat
- Page 33 and 34: FILTERING WOUND BEADS Applications
- Page 35 and 36: FILTERING WOUND BEADS Part No. Rate
- Page 37 and 38: FILTERING ABSORBING SHEET MAB-03 Fe
- Page 39 and 40: GROUNDING GROUNDING CLAMP/RAIL Feat
- Page 41 and 42: GROUNDING GROUNDING MESH/STRAPS Fea
- Page 43 and 44: GROUNDING ON-BOARD CONTACTS OG-5030
- Page 45 and 46: 2 GROUNDING ON-BOARD LUG TERMINAL F
- Page 47 and 48: GROUNDING ON-BOARD CONTACTS Feature
- Page 49 and 50: GROUNDING TECHNICAL ADHESIVE TAPES
- Page 51 and 52: SHIELDING FABRIC FOAM OVER GASKET F
EMI SHIELDING FERRITE<br />
FILTERING<br />
SPLIT FERRITES FOR ROUND CABLE 5-9<br />
FLAT CABLE FERRITES 10-19<br />
ROUND CABLE FERRITES 20-27<br />
FINEMET CORE (F) 28<br />
LOW CUT CORE (TRM) 29<br />
OVAL CORE 30<br />
MULTI APERTURE WOUND BEADS 30<br />
FERRITE PLATES FOR D-SUB AND CPU 31<br />
WOUND BEADS 32-34<br />
FERRITE DESIGN KIT 34<br />
ABSORBING SHEETS 35-36<br />
EMI GROUNDING MATERIAL<br />
GROUNDING<br />
FRAME GROUNDING SPACER 37<br />
GROUNDING CLAMPS 38-39<br />
GROUNDING MESH/STRAPS 40<br />
ON BOARD CONTACTS/CLAMP/CLIP/SOFT CONTACT<br />
LUG TERMINALS 41-46<br />
CONDUCTIVE TAPES 47<br />
TECHNICAL ADHESIVE TAPES FOR SPECIAL APPLICATIONS 48<br />
CONDUCTIVE FABRIC TAPE - CNT 49<br />
EMI SHIELDING MATERIAL<br />
SHIELDING<br />
FABRIC OVER FOAM GAS<strong>KE</strong>T 50-54<br />
FOAMGAS<strong>KE</strong>T KIT 55<br />
CUSTOMISED GAS<strong>KE</strong>T 56<br />
PART NUMBER GUIDE 57<br />
CONDUCTIVE FOAM 58<br />
SHIELDING FABRIC 59-60<br />
D-SUB CONNECTOR-GAS<strong>KE</strong>TS 61<br />
CARBON RUBBER 62<br />
CONDUCTIVE ELASTOMER 63-64<br />
ALL METAL GAS<strong>KE</strong>TS 65<br />
WIRE MESH OVER ELASTOMER CORE GAS<strong>KE</strong>TS 66<br />
MULTISTRIP GAS<strong>KE</strong>TS 67<br />
SYNTHETIC YARN KITTED GAS<strong>KE</strong>TS 68<br />
SPRING SERIES GAS<strong>KE</strong>TS 69<br />
MESH TAPES 70<br />
COPPER BERYLLIUM FINGER STRIPS 71-80<br />
MONOFILAMENT BRAIDED SLEEVING MFS-AG 81-82<br />
GENERAL TERMS OF DELIVERY AND PAYMENT 83-84
QUICK<br />
INDEX<br />
B<br />
BCN 17<br />
C<br />
CB 71-80<br />
CCT 47<br />
CFT-CS 48<br />
CMP-CS 48<br />
CNT 49<br />
CSR-D 62<br />
CSR-P 62<br />
CSR-R 62<br />
CSR-U 62<br />
CSR-O 62<br />
D<br />
DECF 58<br />
E<br />
EFC 17<br />
ESF 34<br />
F<br />
F 28<br />
FCP 16<br />
<strong>FG</strong>C 38<br />
<strong>FG</strong>ES 37<br />
<strong>FG</strong>M 40<br />
<strong>FG</strong>R 38<br />
<strong>FG</strong>S 37<br />
<strong>FG</strong>ST 40<br />
FH 6/8 30<br />
FH 9/15/25/37 31<br />
FOG 46<br />
FP 18<br />
FPC 14-15<br />
FPCK 16<br />
FPH 11<br />
FPI 14<br />
FPO 14<br />
FRC 10<br />
FRH 10<br />
FRHL 10<br />
H<br />
HPC 39<br />
K<br />
KCF 7<br />
<strong>KE</strong>-E1/E2/E3/E4 59-60<br />
<strong>KE</strong>-<strong>FG</strong>-D 53<br />
<strong>KE</strong>-<strong>FG</strong>-F 52<br />
<strong>KE</strong>-<strong>FG</strong>-K 54<br />
<strong>KE</strong>-<strong>FG</strong>-P 54<br />
<strong>KE</strong>-<strong>FG</strong>-R 51-52<br />
<strong>KE</strong>-<strong>FG</strong>-W 54<br />
<strong>KE</strong>-MC 18<br />
<strong>KE</strong>-PC 19<br />
M<br />
MAB-03 36<br />
MFM 36<br />
MFS-AG 81-82<br />
MG-03A/04/05/06 35<br />
MG-B 65<br />
MG-BE 66<br />
MG-C 70<br />
MG-P 65<br />
MG-PE 66<br />
MG-R 65<br />
MG-RE 66<br />
MG-REDM 63<br />
MG-REM 67<br />
MG-SB 69<br />
MG-SD 69<br />
MG-SP 69<br />
MG-ST 69<br />
MG-T 65<br />
MG-TE 66<br />
MG-YDE 68<br />
MG-YRE 68<br />
MG-YTE 68<br />
N<br />
NK 39<br />
O<br />
OG 41-42<br />
OGC 42<br />
OGCP 42<br />
OGP 44<br />
OG-R 44<br />
OGSC 42<br />
OG-K01/02T 44<br />
OGSS 43<br />
R<br />
R6H 32<br />
RFC 5<br />
RFC-H 5<br />
RH-3.5 33-34<br />
RI 20-21<br />
S<br />
SD 31<br />
SFC 6<br />
SG-FO 64<br />
SG-PL 63<br />
SG-RE 63<br />
SG-RO 64<br />
SG-TU 64<br />
SSC 12<br />
SSH 10<br />
T<br />
TFC 9<br />
TFCM 9<br />
TFP 9<br />
TOG 45<br />
TR 22-23<br />
TRCN 8<br />
TRE 30<br />
TRM 29<br />
U<br />
USB 5
FILTERING<br />
SOLVING EMI PROBLEMS IN DATA TRANSMISSION LINES<br />
FILTERING<br />
Relationship between number of<br />
turns (windings) and impedance<br />
vs. frequency<br />
The graphs shown in the right figure<br />
indicate performance curves of one to<br />
four turns from the bottom to the top,<br />
respectively. As the number of turns is<br />
increased, the impedance is enhanced, but<br />
it is known from this figure that the peaks<br />
of impedance are moved downward as<br />
stray capacitance between lines are increased.<br />
Insertion loss can be increased, particularly<br />
at lower frequencies, by increasing the<br />
number of turns of the wire conductor<br />
through the ferrite device. This will damp<br />
the noise without influencing the signals.<br />
Difference in impedance vs. frequency<br />
between split cores and<br />
one-piece cores<br />
The graph shown in the right side compares<br />
characteristics of separated and nonseparated<br />
cores for toroidal cores of the<br />
same size. Although impedance of a separated<br />
core is lower in the area less than<br />
30 MHz, it is similar to or slightly higher<br />
than that of a non-separated one.<br />
The merit of using the separated cores is<br />
that it may be easily mounted in an<br />
already wired cable or a cable which has<br />
been already connected to a connector<br />
and that magnetic saturation in DC occurs<br />
less frequently than in non-separated<br />
ones when large DC current flows<br />
through a line.<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
4
FILTERING<br />
SPLIT FERRITES FOR ROUND CABLE<br />
patented<br />
Features<br />
- Employ high-performance ferrites<br />
(Nickel-Zinc) effective against high<br />
frequency noise<br />
- Ferrite assembly in fully enclosed Nylon<br />
6/6 case can be installed as a single addon<br />
component by snapping. (UL 94 V-0)<br />
- Designed to help reduce cost and time<br />
to market saving.<br />
- Can be installed in its intended location<br />
before or after product assembly by<br />
snapping.<br />
- Black Plastic case available.<br />
Part No.<br />
USB-4<br />
RFC-4<br />
RFC-5<br />
RFC-6<br />
RFC-7<br />
RFC-8<br />
RFC-9<br />
RFC-10<br />
RFC-13<br />
RFC-H13<br />
RFC-20<br />
A<br />
13,9<br />
14,5<br />
18.5<br />
18.5<br />
15.8<br />
20.6<br />
22.6<br />
26.6<br />
29.6<br />
31.7<br />
40.0<br />
Unit: mm Impedance (Ω) 1 turn Impedance (Ω) 2 turn<br />
B C 25MHz 100MHz 25MHz 100MHz<br />
27.0 13.6 122 168 443 614<br />
28.6 13.8 56 149 198 584<br />
34.0 17.8 53 177 126 864<br />
34.0 17.8 53 177 126 864<br />
20.0 13.8 45 75 -<br />
-<br />
34.0 19.8 49 150 173 658<br />
34.0 21.4 64 183 242 760<br />
34.0 25.4 95 236 371 1036<br />
34.0 28.4 90 209 363 878<br />
41.0<br />
47.0<br />
29.4<br />
40.0<br />
200<br />
180<br />
270<br />
260<br />
-<br />
-<br />
-<br />
-<br />
Max.<br />
Cable Diameter<br />
ø 5,5<br />
ø 4,5<br />
ø 5.5<br />
ø 6.5<br />
ø 7.0<br />
ø 9.0<br />
ø 10.0<br />
ø 11.0<br />
ø 14.0<br />
ø 13.5<br />
ø 20.0<br />
RFC-7<br />
RFC-20<br />
RFC-20<br />
5<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
FILTERING<br />
SPLIT FERRITES FOR ROUND CABLE<br />
patented<br />
Features<br />
- Employ high-performance ferrites<br />
(Nickel-Zinc) effective against high frequency<br />
noise<br />
- Ferrite assembly in fully enclosed Nylon<br />
6/6 case, can be installed as a single addon<br />
component by snapping. (UL 94 V-0)<br />
- Spring stainless steel (SUS 304-CSP)<br />
incorporates ensure a tighter surface contact<br />
between ferrites for a consistent performance.<br />
- Designed to help reduce cost and time<br />
to market saving.<br />
- Can be installed in its intended location<br />
before or after product assembly by snapping.<br />
Part No.<br />
SFC-3<br />
SFC-4<br />
SFC-5<br />
SFC-6<br />
SFC-8<br />
SFC-10<br />
A<br />
13.4<br />
16.3<br />
21.0<br />
23.5<br />
23.5<br />
32.6<br />
Black plastic case available (-BK)<br />
Unit: mm Impedance (Ω) 1 turn Impedance (Ω) 2 turn<br />
B<br />
C 25MHz 100MHz 25MHz 100MHz<br />
18.9 13.2 45 80 163 301<br />
29.5 15.0 96 138 401 522<br />
32.0 17.5 177 242 660 766<br />
32.0 20.0 139 207 614 629<br />
32.0 20.0 137 204 573 663<br />
32.0 29.0 149 266 640 733<br />
Max.<br />
Cable Diameter<br />
ø3<br />
ø4 to ø5<br />
ø5 to ø6<br />
ø6 to ø7<br />
ø7,8 to ø8,5<br />
ø9,5 to ø10,5<br />
FILTERING<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
6
FILTERING<br />
SPLIT FERRITES FOR ROUND CABLE<br />
Features<br />
- Split construction permits easy insertion<br />
on pre-installed cable and installed<br />
or cables with connectors.<br />
- Kept in a plastic case, ferrite will not<br />
crack or chip. (UL 94 V-2)<br />
- Cable is fixed firmly by plastic housing<br />
C<br />
Applications<br />
- For noise problems arising from<br />
office automation equipment or other<br />
digital equipment.<br />
- Internal and external power cable.<br />
- Internal cables between PC boards<br />
and data connectors.<br />
- White Plastic case available.<br />
B<br />
A<br />
Part No.<br />
KCF-50<br />
KCF-65<br />
KCF-100<br />
KCF-130<br />
A<br />
23.0<br />
32.6<br />
32.6<br />
32.7<br />
Unit: mm<br />
B<br />
15.0<br />
17.8<br />
22.5<br />
29.2<br />
C<br />
14.0<br />
19.2<br />
23.0<br />
30.2<br />
Impedance (Ω)<br />
25MHz<br />
100MHz<br />
93<br />
157<br />
176<br />
267<br />
151<br />
226<br />
152<br />
228<br />
Max.<br />
Cable Diameter<br />
ø 5.0<br />
ø 6.5<br />
ø 10.0<br />
ø 13.0<br />
7<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
FILTERING<br />
SPLIT FERRITES FOR ROUND CABLE<br />
Features<br />
- Split construction permits easy insertion<br />
of cables already wired and<br />
installed, or cables with connectors.<br />
- Comes with nylon mounting clamp.<br />
- Clamps are made of UL recognized<br />
6/6 nylon (UL94V-2)<br />
Application<br />
For noise problems arising from office<br />
automation equipment or other digital<br />
equipment.<br />
Part No.<br />
TRCN-16-8-13<br />
TRCN-16-8-16<br />
TRCN-20-10-10<br />
TRCN-23-11-14<br />
TRCN-28-16-13<br />
TRCN-28-16-20<br />
TRCN-40-27-15<br />
A<br />
19.4<br />
19.4<br />
25.7<br />
26.8<br />
32.8<br />
32.8<br />
44.6<br />
B<br />
8.2<br />
8.2<br />
10.4<br />
11.4<br />
16.4<br />
16.4<br />
27.4<br />
Unit: mm<br />
C<br />
13.0<br />
16.0<br />
10.0<br />
14.0<br />
13.0<br />
20.0<br />
15.0<br />
D<br />
30.2<br />
30.2<br />
38.2<br />
39.4<br />
45.0<br />
45.0<br />
57.3<br />
F<br />
4.3<br />
4.3<br />
5.1<br />
5.1<br />
5.1<br />
5.1<br />
5.1<br />
Impedance (Ω) 1 turn Impedance (Ω) 2 turn<br />
25MHz 100MHz 25MHz 100MHz<br />
59 93 231 396<br />
64 106 291 504<br />
53 84 203 360<br />
72 112 289 449<br />
56 90 226 374<br />
79 135 325 579<br />
48 84 195 365<br />
Max.<br />
Cable Diameter<br />
ø 8.0 or less<br />
ø 8.0 or less<br />
ø 10.0 or less<br />
ø 11.0 or less<br />
ø 16.0 or less<br />
ø 16.0 or less<br />
ø 27.0 or less<br />
FILTERING<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
8
FILTERING<br />
SPLIT FERRITES FOR ROUND CABLE<br />
patented<br />
Features<br />
- Employ high-performance ferrites (Nickel-Zinc) effective against high<br />
frequency noise<br />
- Ferrite assembly in fully enclosed Nylon 6/6 case, can be installed as a single<br />
add-on component by snapping. (UL 94 V-0)<br />
- Special mounting options include adhesive tape, or screw type through holes<br />
provided.<br />
Application<br />
- Superior suppression of radiation emissions for full compliance with FCC, VDE<br />
and VCCI on interface/ data line round cables of computers, peripheral/terminal<br />
equipment.<br />
A<br />
B<br />
Fig. 1 Fig. 2 Fig. 3 Fig. 4<br />
A<br />
C<br />
C<br />
B<br />
A<br />
E<br />
B<br />
C<br />
B<br />
C<br />
D<br />
D<br />
D<br />
D<br />
A<br />
Part No.<br />
TFC 16813<br />
TFC 16816<br />
TFCM 16-8-13<br />
TFCM 16-8-16<br />
TFC 20-10-10<br />
TFC 23-11-14<br />
TFC 25-15-12<br />
TFCM 41-27-16<br />
TFP 2014-T<br />
TFP 2014-V<br />
Fig.<br />
1<br />
1<br />
2<br />
2<br />
3<br />
3<br />
3<br />
1*<br />
4<br />
4<br />
A<br />
19.8<br />
19.8<br />
19.8<br />
19.8<br />
24.2<br />
27.4<br />
28.2<br />
44<br />
20<br />
20<br />
B<br />
7.6<br />
7.6<br />
7.6<br />
7.6<br />
8.8<br />
10.8<br />
13.6<br />
26.6<br />
13.5<br />
13.5<br />
Unit: mm<br />
C<br />
18.9<br />
21.9<br />
18.9<br />
21.9<br />
13.5<br />
17.5<br />
13.7<br />
19.6<br />
7.2<br />
7.2<br />
D<br />
19.8<br />
19.8<br />
22.3<br />
22.3<br />
27.9<br />
31.0<br />
30.9<br />
48.2<br />
4.8<br />
4.8<br />
E<br />
-<br />
-<br />
-<br />
-<br />
19.9<br />
23.9<br />
20.1<br />
Impedance (Ω) 1 trun Impedance (Ω) 2 trun<br />
25 MHz<br />
57<br />
73<br />
57<br />
73<br />
47<br />
72<br />
41<br />
50<br />
100 MHz<br />
115<br />
139<br />
115<br />
139<br />
92<br />
132<br />
88<br />
100<br />
25 MHz<br />
237<br />
300<br />
237<br />
300<br />
192<br />
301<br />
167<br />
100 MHz<br />
517<br />
597<br />
517<br />
597<br />
410<br />
547<br />
390<br />
Mounting part with adhesive tape<br />
Mounting part for screw ø3.4mm<br />
Applicable cable<br />
diameter (mm)<br />
ø7.2 max<br />
ø7.2 max<br />
ø7.2 max<br />
ø7.2 max<br />
ø8.5 max<br />
ø10.5 max<br />
ø13.0 max<br />
ø26.0 max<br />
9<br />
1* Shape is slightly different, please ask for drawing.<br />
<strong>KE</strong> KITAGAWA<br />
TFCR series (TFC/TFCM ferrite with<br />
re-use clamp) are available.<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
FILTERING<br />
FLAT CABLE FERRITES<br />
Features<br />
- Employ high-performance ferrites<br />
(Nickel-Zinc) effective against high<br />
frequency noise.<br />
- Special mounting options include<br />
adhesive tape, or screw type through<br />
holes available.<br />
- Designed to help reduce cost and time<br />
to market saving.<br />
- Can be installed in its intended location<br />
before or after product assembly<br />
simply with Mounting part.<br />
Applications<br />
- Superior suppression of radiation<br />
emissions for full compliance with<br />
FCC, VDE and VCCI on Interface/<br />
data line ribbon cables of computers,<br />
peripheral/terminal equipment.<br />
Part No.<br />
SSH-33.5-12<br />
SSH-33.5-20<br />
SSH-40-12<br />
SSH-45-12<br />
A<br />
33.5<br />
33.5<br />
40.0<br />
45.0<br />
B<br />
1.2<br />
1.2<br />
1.2<br />
1.2<br />
Unit: mm<br />
C<br />
6.6<br />
6.6<br />
6.6<br />
6.6<br />
D<br />
12<br />
20<br />
12<br />
12<br />
E<br />
27<br />
27<br />
35<br />
40<br />
Impedance (Ω)<br />
25MHz 100MHz<br />
33 63<br />
52 92<br />
27 61<br />
25 60<br />
Max.<br />
Cable Width (mm)<br />
26<br />
26<br />
34<br />
39<br />
FILTERING<br />
Mounting Parts for SSH type cores + SSC type cores<br />
Part No.:<br />
Material:<br />
FRH-12<br />
PA66 UL94V-0<br />
Part No.:<br />
Material:<br />
FRC-12CP<br />
PA66 UL94V-0<br />
Part No.:<br />
Material:<br />
FRHL-20<br />
PA66 UL94V-2<br />
Part No.<br />
FRH-12<br />
FRHL-20<br />
FRC-12CP<br />
Mounting part for screw (D = > 12mm)<br />
Mounting part for screw (D > = 20mm)<br />
Mounting part<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
10
FILTERING<br />
FLAT CABLE FERRITES<br />
Features<br />
- Employ high-performance ferrites<br />
(Nickel-Zinc) effective against high<br />
frequency noise.<br />
- Designed to help reduce cost and time<br />
to market saving.<br />
- Can be installed in its intended location<br />
before or after product assembly.<br />
Application<br />
- Superior suppression of radiation<br />
emissions for full compliance with<br />
FCC, VDE and VCCI on Interface/<br />
data line ribbon cables of computers,<br />
peripheral/terminal equipment.<br />
No Mounting Parts available for all size<br />
Part No.<br />
FPH-10-6-5<br />
A<br />
10<br />
B<br />
1.8<br />
Unit: mm<br />
C<br />
5.0<br />
D<br />
6.0<br />
E<br />
6.8<br />
Impedance (Ω)<br />
100MHz<br />
20<br />
Max.<br />
Cable Width (mm)<br />
6.5<br />
FLAT CABLE FERRITES<br />
Features<br />
- Employ high-performance ferrites<br />
(Nickel-Zinc) effective against high<br />
frequency noise.<br />
- Designed to help reduce cost and time<br />
to market saving.<br />
- Can be installed in its intended location<br />
before or after product assembly.<br />
C<br />
A<br />
B<br />
F<br />
E<br />
Application<br />
- Superior suppression of radiation<br />
emissions for full compliance with<br />
FCC, VDE and VCCI on Interface data<br />
line ribbon cables of computers peripheral/terminal<br />
equipment.<br />
D<br />
2,0<br />
1,1<br />
1,2<br />
Part No.<br />
FPO-23-8-3<br />
FPO-25-12-3<br />
FPO-31-12-3<br />
FPI-20-12-1,2<br />
A<br />
23.0<br />
25.0<br />
31.0<br />
-<br />
B<br />
19.0<br />
21.0<br />
27.0<br />
-<br />
C<br />
8.0<br />
12.0<br />
12.0<br />
-<br />
Unit: mm<br />
D<br />
2.8<br />
2.8<br />
2.8<br />
-<br />
E<br />
18.5<br />
20.5<br />
26.5<br />
20.5<br />
F<br />
8.0<br />
12.0<br />
12.0<br />
12.0<br />
Impedance (Ω)<br />
25MHz 100MHz<br />
18 42<br />
25 56<br />
24 55<br />
- -<br />
Max.<br />
Cable Width (mm)<br />
18.5<br />
20.5<br />
26.6<br />
-<br />
No Mounting Parts available for all size<br />
11<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
FILTERING<br />
FLAT CABLE FERRITES<br />
Features<br />
- Employ high-performance ferrites<br />
(Nickel-Zinc) effective against high<br />
frequency noise.<br />
- Designed to help reduce cost and time<br />
to market saving.<br />
- Can be installed in its intended locati<br />
on before product assembly.<br />
Applications<br />
- Superior suppression of radiation<br />
emissions for full compliance with<br />
FCC, VDE and VCCI on Interface/ data<br />
line Ribbon/FPC cables of computers,<br />
peripheral/terminal equipment.<br />
Fig.1<br />
B<br />
C<br />
D<br />
B<br />
C<br />
D<br />
FILTERING<br />
Part No.<br />
SSC-21-6.8-8B<br />
SSC-21-6.8-15B<br />
SSC-23.3-3-7<br />
SSC-23.8-6.3-7<br />
SSC-23.8-6.3-12.5<br />
SSC-23.8-6.3-15<br />
SSC-28.5-6.5-8<br />
SSC-28-7.7-14.6<br />
SSC-33.5-8<br />
SSC-33.5-10<br />
SSC-33.5-12<br />
SSC-33.5-10-2<br />
SSC-33.5-20<br />
SSC-38.5-4-12<br />
SSC-38.5-12-25.4<br />
SSC-40-10<br />
SSC-40-12<br />
SSC-45-8<br />
SSC-45-12<br />
SSC-50-12<br />
SSC-58-12<br />
SSC-60-12<br />
Fig.<br />
2<br />
2<br />
2<br />
1<br />
1<br />
1<br />
1<br />
3<br />
1<br />
1<br />
1<br />
1<br />
1<br />
2<br />
2<br />
1<br />
1<br />
1<br />
1<br />
1<br />
1<br />
1<br />
A<br />
21.0±0.5<br />
21.0±0.5<br />
23.3±0.7<br />
23.8±0.7<br />
23.8±0.8<br />
23.8±0.8<br />
28.5±0.7<br />
28.0±0.8<br />
33.5±1.0<br />
33.5±1.0<br />
33.5±1.0<br />
33.5±0.9<br />
33.5±0.9<br />
38.5±1.0<br />
38.53±0.58<br />
40.0±1.0<br />
40.0±1.0<br />
45.2±1.0<br />
45.2±1.0<br />
49.6±1.0<br />
57.6±1.20<br />
60.6±1.1<br />
B<br />
1.3+0.4/-0.1<br />
1.3+0.4/-0.1<br />
0.9±0.2<br />
1.3±0.25<br />
1.1±0.4<br />
1.1±0.4<br />
0.85±0.3<br />
1.4±0.2<br />
1.4±0.4<br />
1.4±0.4<br />
1.4±0.4<br />
2.2±0.3<br />
1.4±0.4<br />
0.8±0.3<br />
1.9±0.38<br />
1.4±0.4<br />
1.4±0.4<br />
1.4±0.4<br />
1.4±0.4<br />
1.4±0.4<br />
1.4±0.4<br />
1.4±0.4<br />
Unit: mm<br />
C<br />
6.8±0.3<br />
6.8±0.3<br />
3.1±0.3<br />
6.3±0.3<br />
6.3±0.4<br />
6.3±0.4<br />
6.5±0.5<br />
7.7±0.3<br />
6.5±0.5<br />
6.5±0.5<br />
6.5±0.5<br />
7.4±0.4<br />
6.5±0.5<br />
4.0±0.2<br />
12.06±0.38<br />
6.5±0.5<br />
6.5±0.5<br />
6.5±0.5<br />
6.5±0.5<br />
6.5±0.5<br />
6.5±0.5<br />
6.5±0.5<br />
D<br />
8.0±0.3<br />
15.0±0.4<br />
7.0±0.3<br />
7.0±0.3<br />
12.5±0.4<br />
15.0±0.4<br />
8.0±0.4<br />
14.6±0.4<br />
8.0±0.4<br />
10.0±0.4<br />
12.0±0.5<br />
10.0±0.5<br />
20.0±0.6<br />
12.0±0.5<br />
25.4±0.76<br />
10.0±0.45<br />
12.0±0.5<br />
8.0±0.3<br />
12.0±0.5<br />
12.0±0.5<br />
12.0±0.5<br />
12.0±0.5<br />
E<br />
15.0±0.5<br />
15.0±0.5<br />
20.0±0.5<br />
18.4±0.5<br />
18.7±0.8<br />
18.7±0.8<br />
23.5±0.5<br />
23.0±0.5<br />
27.0±0.5<br />
27.0±0.5<br />
27.0±0.5<br />
27.0+0.9/-0.6<br />
27.15±0.75<br />
35.0±0.7<br />
26.77±0.76<br />
35.0±0.7<br />
35.0±0.7<br />
40.0±0.8<br />
40.0±0.8<br />
44.0±0.8<br />
52.0±0.8<br />
55.2±1.0<br />
Impedance (Ω)<br />
25MHz 100MHz<br />
32 44<br />
60 75<br />
17 45<br />
27 58<br />
29 83<br />
46 88<br />
28 65<br />
55 115<br />
21 44<br />
26 51<br />
31 58<br />
27 50<br />
58 149<br />
25 68<br />
86 166<br />
23 54<br />
27 60<br />
19 46<br />
26 61<br />
25 64<br />
25 63<br />
35 92<br />
Max. Cable<br />
Width (mm)<br />
14<br />
14<br />
19<br />
18<br />
18<br />
18<br />
22<br />
22<br />
26<br />
26<br />
26<br />
26<br />
26<br />
34<br />
26<br />
34<br />
34<br />
39<br />
39<br />
43<br />
51<br />
54<br />
Mounting Parts Page 10 + 16<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
12
FILTERING<br />
FLAT CABLE FERRITES<br />
13<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
FILTERING<br />
SLIM<br />
CORE<br />
Features<br />
Ultra thin ferrite core for FPC ideal for<br />
space-saving devices<br />
- Reducedd thickness allows an effective<br />
use in a limited space<br />
- Despite the low profile, high performance<br />
is achieved by close contact to<br />
FPC cable<br />
Part No.<br />
FPC-11-3-2<br />
FPC-11-8-2<br />
FPC-18-3-2<br />
FPC-18-8-2<br />
FPC-22-8-2<br />
A<br />
11.0<br />
11.0<br />
18.0<br />
18.0<br />
21.5<br />
B<br />
0.7, +0.2-0.3<br />
0.7, +0.2-0.3<br />
0.7, +0.2-0.3<br />
0.7, +0.2-0.3<br />
0.7, +0.2-0.25<br />
Unit: mm<br />
C<br />
2.3<br />
D<br />
3<br />
8<br />
3<br />
8<br />
8<br />
E<br />
9±0.3<br />
9±0.3<br />
14.5±0.4<br />
14.5±0.4<br />
18±0.5<br />
Impedance<br />
Min(Ω)/100MHz(1turn)<br />
10<br />
20<br />
10<br />
15<br />
20<br />
FILTERING<br />
1000<br />
1000<br />
Impedance (Ω)<br />
100<br />
10<br />
Impedance (Ω)<br />
100<br />
10<br />
1<br />
1<br />
10<br />
100<br />
Frenqueny (MHz)<br />
1000<br />
1<br />
1<br />
10<br />
100<br />
Frenqueny (MHz)<br />
1000<br />
Slim Core<br />
(FPC-18-8-2)<br />
Existing product<br />
FPC-11-8-2<br />
Slim Core<br />
L= 8 mm<br />
FPC-11-3-2<br />
Slim Core<br />
L= 3 mm<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
14
FILTERING<br />
FLAT CABLE FERRITES<br />
Features<br />
- Employ high-performance ferrites<br />
(Nickel-Zinc) effective against high<br />
frequency noise.<br />
- Designed to help reduce cost and time<br />
to market saving.<br />
- Can be installed simply in its intended<br />
location before product assembly.<br />
- Mounting part, FPCK12A, 12B is<br />
available<br />
Applications<br />
- Superior suppression of radiation<br />
emissions for full compliance with<br />
FCC, VDE and VCCI on Interface/<br />
data line FPC cables of computers,<br />
peripheral/terminal equipment.<br />
Part No.<br />
FPC 16-12<br />
FPC-16-20<br />
FPC-25-12<br />
FPC-25-20<br />
FPC-31-12<br />
FPC-46-12<br />
FPC-56-12<br />
FPC-24-12-3<br />
FPC-31-12-3<br />
A<br />
16.0±0.4<br />
16.0±0.4<br />
24.5±0.7<br />
24.5±0.7<br />
31.0±1.0<br />
46.0+1.1/-0.8<br />
56.2±1.1<br />
23.3±0.7<br />
31.0±0.8<br />
B<br />
0.5+0.6/-0.0<br />
0.5+0.6/-0.0<br />
0.5+0.6/-0.0<br />
0.85±0.25<br />
1.0±0.2<br />
0.5+1.0/-0.0<br />
0.5+1.1/-0.0<br />
0.9±0.2<br />
0.9±0.2<br />
Unit: mm<br />
C<br />
5.0+0.0/-0.7<br />
5.0+0.0/-0.7<br />
5.0+0.0/-0.7<br />
5.0+0.0/-0.7<br />
5.0±0.3<br />
5+0.0/-0.8<br />
5+0.3/-1.1<br />
3.1±0.3<br />
3.0±0.2<br />
D<br />
12.0±0.5<br />
20.0±0.6<br />
12.0±0.4<br />
20.0±0.6<br />
12.0±0.5<br />
12.0±0.8<br />
12.0±0.5<br />
12.0±0.5<br />
12.0±0.5<br />
E<br />
11.5±0.4<br />
11.5±0.4<br />
20.0±0.5<br />
20.0±0.5<br />
27.0±0.7<br />
41.5±0.9<br />
52.4±0.9<br />
20.0±0.5<br />
27.0±0.6<br />
Impedance (Ω)<br />
25MHz 100MHz<br />
42 79<br />
71 127<br />
30 65<br />
50 103<br />
26 66<br />
23 65<br />
23 66<br />
20 41<br />
17 42<br />
Max.Cable<br />
width (mm)<br />
10.5<br />
10.5<br />
19.0<br />
19.0<br />
26.0<br />
40.5<br />
51.0<br />
19.0<br />
26.0<br />
15<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
FILTERING<br />
FLAT CABLE FERRITES<br />
Mounting Parts for FPC type cores<br />
Part No.:<br />
Material:<br />
Applicable:<br />
FPCK-12B<br />
PVC<br />
FPC-31-12<br />
FPC-46-12<br />
FPC-56-12<br />
FPC-31-12-3<br />
Part No.<br />
FPCK-12B<br />
FPCK-12A<br />
Part No.:<br />
Material:<br />
Applicable:<br />
FPCK-12A<br />
PVC<br />
FPC-16-12<br />
FPC-25-12<br />
FPC-24-12-3<br />
Applicable<br />
FPC-31-12, FPC-46-12; FPC-56-12; FPC-31-12-3<br />
FPC-16-12; FPC-25-12; FPC-24-12-3<br />
FILTERING<br />
Mounting Parts for SSC type cores<br />
Features<br />
- Plastic clip for SSC-cores<br />
- Material: ABS<br />
- Colour: black<br />
Part No.<br />
FCP-15P<br />
FCP-25P<br />
FCP-34P<br />
FCP-40P<br />
A<br />
34,5<br />
46,5<br />
56,6<br />
64,1<br />
B<br />
0,8<br />
0,8<br />
0,8<br />
0,8<br />
Unit: mm<br />
C<br />
12,0<br />
10,6<br />
10,4<br />
10,4<br />
D<br />
19,0<br />
16,0<br />
16,0<br />
16,0<br />
E<br />
21,6<br />
34,3<br />
43,2<br />
53,3<br />
Applicable<br />
SSC-21-6,8-8 / 21-6,8-15 / 23,8-6,3-7 / 23,8-6,3-15 / 28-7,7-14,6<br />
SSC-33,5-8 / 33,5-10 / 33,5-12 / 33,5-10-2 / 40-10 / 40-12<br />
SSC-45-8 / 45-12 / 50-12<br />
SSC-58-12<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
16
FILTERING<br />
FLAT CABLE FERRITES<br />
Features<br />
- Split construction permits easy insertion<br />
of cables already wired and<br />
installed, or cables with connectors.<br />
- Nylon mounting clamp comes with.<br />
- Split block cores supported with plastic<br />
mounting clamp for flat cables<br />
Applications<br />
- For noise problems arising in<br />
office automation equipment or<br />
other digital equipment.<br />
Part No.<br />
EFC-25S<br />
EFC-40S<br />
EFC-50S<br />
EFC-25N<br />
EFC-40N<br />
EFC-50N<br />
BCN-26<br />
BCN-40<br />
BCN-50<br />
A<br />
44.0<br />
630<br />
76.5<br />
44.0<br />
63.0<br />
76.5<br />
45.0<br />
63.0<br />
76.5<br />
B<br />
2.0<br />
2.0<br />
2.0<br />
2.0<br />
2.0<br />
2.0<br />
2.0<br />
2.0<br />
2.0<br />
C<br />
13.0<br />
13.0<br />
13.0<br />
13.0<br />
13.0<br />
13.0<br />
13.0<br />
13.0<br />
13.0<br />
Unit: mm<br />
D<br />
28.5<br />
28.5<br />
28.5<br />
28.5<br />
28.5<br />
28.5<br />
28.5<br />
28.5<br />
28.5<br />
E<br />
33.0<br />
52.0<br />
64.5<br />
33.0<br />
52.4<br />
64.5<br />
34.0<br />
52.0<br />
64.5<br />
F<br />
47.0<br />
77.0<br />
79.5<br />
47.0<br />
77.0<br />
79.5<br />
59.0<br />
76.5<br />
90.7<br />
P<br />
33.0<br />
64.5<br />
64.5<br />
–<br />
–<br />
–<br />
–<br />
–<br />
–<br />
25MHz<br />
65<br />
72<br />
62<br />
65<br />
72<br />
62<br />
92<br />
72<br />
63<br />
Impedance (Ω)<br />
100MHz<br />
150<br />
175<br />
185<br />
150<br />
175<br />
185<br />
180<br />
180<br />
185<br />
Applicable cable<br />
flat cable<br />
Less than the<br />
dimension E<br />
17<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
FILTERING<br />
FLAT CABLE FERRITES<br />
Features<br />
- Kitagawa offers a line of bisected flat<br />
cable suppression cores to attenuate<br />
radiated EMI emissions from ribbon<br />
cables.<br />
- Ferrite assembly press-fitted into a<br />
pair of metal clips.<br />
- Metal clips included, except<br />
FP 16,5-2-10.25<br />
Applications<br />
- Internal ribbon cables between PCB<br />
and Data line.<br />
- To suppress radiated EMI emission<br />
from flat cable and ribbon cable.<br />
Part No.<br />
FP 16.5-2-10.25<br />
FP 38-6.35-10<br />
FP 38-6.35-25.4<br />
FP 45-6.35-10<br />
FP 45-6.35-28.5<br />
FP 55.1-6.35-28.5<br />
FP 63.5-6.35-13<br />
FP 63.5-6.35-15<br />
FP 63.5-6.35-28.5<br />
FP 76.2-6.35-28.5<br />
*<br />
*<br />
*<br />
**<br />
**<br />
*<br />
*<br />
**<br />
**<br />
A<br />
16.5±0.25<br />
38.0±1.0<br />
38.0±1.0<br />
45.0±0.75<br />
45.0±0.75<br />
55.1±1.2<br />
63.5±1.3<br />
63.5±1.3<br />
63.5±1.3<br />
76.2±1.5<br />
B<br />
0.6±0.2<br />
0.8±0.2<br />
0.8±0.2<br />
0.8±0.2<br />
0.8±0.2<br />
0.8±0.2<br />
0.8±0.2<br />
0.8±0.2<br />
0.8±0.2<br />
0.8±0.2<br />
Unit: mm<br />
C<br />
2.0±0.2<br />
6.35±0.25<br />
6.35±0.25<br />
6.35±0.25<br />
6.35±0.25<br />
6.35±0.25<br />
6.35±0.25<br />
6.35±0.25<br />
6.35±0.25<br />
6.35±0.25<br />
D<br />
10.25±0.2<br />
10.0±0.4<br />
25.4±0.75<br />
10.0±0.4<br />
28.5±0.7<br />
28.5±0.7<br />
13.0±0.4<br />
15.0±0.4<br />
28.5±0.7<br />
28.5±0.7<br />
E<br />
12.5±0.3<br />
26.6±0.7<br />
26.6±0.7<br />
34.4±0.7<br />
34.4±0.7<br />
43.7±1.0<br />
52.0±1.1<br />
52.0±1.1<br />
52.0±1.1<br />
65.3±1.3<br />
25MHz<br />
29<br />
45<br />
103<br />
41<br />
84<br />
78<br />
45<br />
50<br />
74<br />
72<br />
Impedance (Ω)<br />
100MHz<br />
72<br />
107<br />
173<br />
98<br />
166<br />
179<br />
114<br />
124<br />
155<br />
200<br />
FILTERING<br />
* Metal clips (<strong>KE</strong>-MC-10 or <strong>KE</strong> MC-13) are included<br />
** Metal clips (<strong>KE</strong>-MC-13) are included, however Plastic clip <strong>KE</strong>-PC-28.5 is also available as option<br />
Metal Clip for FP-core<br />
Features<br />
- Metal clip for FP-core<br />
- Part No. <strong>KE</strong>-MC-10<br />
- Part No. <strong>KE</strong>-MC-13<br />
10<br />
Ø 0.7<br />
12.5<br />
11.6<br />
15.7<br />
3.5<br />
15.4 7.6 12.7<br />
<strong>KE</strong>-MC-10<br />
<strong>KE</strong>-MC-13<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
18
FILTERING<br />
FLAT CABLE FERRITES<br />
Mounting parts for FP-cores<br />
Features<br />
- Plastic clip for FP- cores<br />
- Nylon 6.6 (UL 94 V-2)<br />
- Colour grey<br />
- Screw mounting<br />
- Part No. <strong>KE</strong>-PC-28.5<br />
<strong>KE</strong>-PC-28.5<br />
19<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
FILTERING<br />
ROUND CABLE FERRITES<br />
Features<br />
- Employ high-performance Ferrites<br />
(Nickel-Zinc). Particularly suitable<br />
for high frequency noise.<br />
- Typically wound with two or three<br />
turns of cable. The impedance ratio is<br />
actually proportional to the square<br />
of the turn.<br />
- Can be installed in its intended location<br />
before product assembly.<br />
A<br />
C<br />
B<br />
Applications<br />
- Superior suppression of radiation<br />
emissions for full compliance with<br />
FCC, VDE and VCCI on Interface/ data<br />
line cables of computers,<br />
peripheral/terminal equipment.<br />
Part No.<br />
RI 2.5-4-0.8<br />
RI 3-4-1<br />
RI 3.5-3-1.2<br />
RI 3.5-3.5-1.2<br />
RI 3.5-4-1.2<br />
RI 3.5-5-1.8<br />
RI 3.5-6-1.2<br />
RI 3.5-7-1.2<br />
RI 4-5-2<br />
RI 4-10-2<br />
RI 5-5-2.3<br />
RI 5-11-1.5<br />
RI 5-18-2.2<br />
RI 6-18-3.2<br />
RI 6.35-12.7-3.3<br />
RI 7.5-7.5-2.4<br />
RI 9.3-9.5-4.5<br />
RI 9.5-9.5-5.2<br />
RI 9.5-10-5.8<br />
RI 9.5-10.4-5<br />
RI 9.5-14.5-5<br />
RI 9.5-19-5<br />
RI 10-6-6<br />
RI 10-10-7<br />
RI 10-14-6<br />
RI 11-18-5<br />
RI 11-20-5<br />
RI 11-25-5<br />
RI 11.8-15-7.3<br />
RI 12.0-7.5-7.0<br />
RI 12-15-7<br />
A<br />
2.5±0.15<br />
3.0±0.15<br />
3.5±0.15<br />
3.5±0.15<br />
3.5±0.15<br />
3.5±0.15<br />
3.5±0.15<br />
3.5±0.15<br />
4.0±0.2<br />
4.0±0.2<br />
5.0±0.2<br />
5.0±0.2<br />
5.0±0.2<br />
6.0±0.2<br />
6.35±0.2<br />
7.50±0.3<br />
9.3±0.3<br />
9.5±0.3<br />
9.5±0.3<br />
9.5±0.3<br />
9.5±0.3<br />
9.5±0.3<br />
10.0±0.2<br />
10.0±0.3<br />
10.0±0.3<br />
11.0±0.3<br />
10.5±0.3<br />
11.0±0.3<br />
11.8±0.3<br />
12.0±0.3<br />
12.0±0.3<br />
Unit: mm<br />
B<br />
4.0±0.3<br />
4.0±0.3<br />
3.0±0.2<br />
3.5±0.2<br />
4.0±0.3<br />
5.0±0.3<br />
6.0±0.3<br />
7.0±0.3<br />
5.0±0.3<br />
10.0±0.4<br />
5.0±0.3<br />
11.0±0.4<br />
18.0±0.4<br />
18.0±0.4<br />
12.7±0.4<br />
7.50±0.3<br />
9.5±0.3<br />
9.5±0.3<br />
10.0±0.3<br />
10.4±0.4<br />
14.5±0.4<br />
19.0±0.4<br />
6.0±0.3<br />
10.0±0.4<br />
14.0±0.4<br />
18.5±0.4<br />
20.0±0.4<br />
25.0±0.6<br />
15.0±0.4<br />
7.5±0.3<br />
15.0±0.4<br />
C<br />
0.8±0.15<br />
1.0±0.15<br />
1.2±0.15<br />
1.2±0.15<br />
1.2±0.15<br />
1.8±0.15<br />
1.2±0.15<br />
1.2±0.15<br />
2.0±0.15<br />
2.0±0.15<br />
2.3±0.15<br />
1.5±0.15<br />
2.15±0.15<br />
3.15±0.2<br />
3.3±0.2<br />
2.40±0.15<br />
4.5±0.25<br />
5.2±0.25<br />
5.8±0.2<br />
5.0±0.25<br />
5.0±0.25<br />
5.0±0.25<br />
6.0±0.2<br />
7.0±0.3<br />
6.0±0.3<br />
5.0±0.25<br />
5.5±0.25<br />
5.0±0.25<br />
7.0±0.3<br />
7.0±0.3<br />
7.0±0.3<br />
Impedance (Ω)<br />
25MHz 100MHz<br />
22<br />
58<br />
32<br />
55<br />
24<br />
46<br />
24<br />
43<br />
28<br />
52<br />
26<br />
52<br />
34<br />
61<br />
43<br />
76<br />
20<br />
42<br />
44<br />
67<br />
28<br />
48<br />
71<br />
126<br />
74<br />
114<br />
100<br />
155<br />
61<br />
97<br />
59<br />
107<br />
47<br />
94<br />
46<br />
91<br />
40<br />
79<br />
53<br />
82<br />
62<br />
109<br />
67<br />
125<br />
27<br />
47<br />
32<br />
68<br />
49<br />
86<br />
89<br />
143<br />
74<br />
115<br />
118<br />
187<br />
49<br />
90<br />
32<br />
66<br />
49<br />
90<br />
FILTERING<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
20
FILTERING<br />
ROUND CABLE FERRITES<br />
Part No.<br />
RI 12-16-8.5<br />
RI 12-20-5.6<br />
RI 12-30-5.6<br />
RI 12.3-25.4-4.9<br />
RI 12.5-12.5-8<br />
RI 12.7-12.7-7.9<br />
RI 14-18-6<br />
RI 14.2-15-6.4<br />
RI 14.2-28.5-6.4<br />
RI 14.2-28.5-7<br />
RI 14.2-28.5-8<br />
RI 15-12-10.5<br />
RI 15.3-28-8<br />
RI 15.7-28.6-6.99<br />
RI 15.9-28.6-7.9<br />
RI 16-28-7<br />
RI 16-28-9<br />
RI 16-28.5-8<br />
RI 16-17-9<br />
RI 17.1-25.4-8.8<br />
RI 17.5-28.5-9.5<br />
RI 17.5-28.5-10.7<br />
RI 17.5-35-9.5<br />
RI 18-28-10<br />
RI 19-29-13<br />
RI 25.9-28.6-12.8<br />
RI 26-28-13<br />
RI 28-28-14<br />
RI 28.5-28.6-13.8<br />
A<br />
12.0±0.5<br />
12.0±0.3<br />
12.0±0.3<br />
12.32±0.3<br />
12.5±0.3<br />
12.7±0.3<br />
14.2±0.3<br />
14.2±0.4<br />
14.2±0.4<br />
14.2±0.4<br />
14.2±0.4<br />
15.0±0.4<br />
15.25±0.4<br />
15.65±0.4<br />
15.88±0.4<br />
16.0±0.4<br />
16.0±0.4<br />
16.0±0.4<br />
16.0±0.4<br />
17.07±0.4<br />
17.5±0.4<br />
17.5±0.4<br />
17.5±0.4<br />
18.0±0.5<br />
19.0±0.5<br />
25.91±0.46<br />
26.0±0.6<br />
28.0±0.6<br />
28.5±0.46<br />
Unit: mm<br />
B<br />
16.0±0.5<br />
20.0±0.5<br />
30.0±0.6<br />
25.4±0.6<br />
12.5±0.4<br />
12.7±0.4<br />
18.0±0.4<br />
15.0±0.4<br />
28.5±0.6<br />
28.5±0.6<br />
28.5±0.6<br />
12.0±0.4<br />
28.0±0.6<br />
28.57±0.6<br />
28.57±0.6<br />
28.0±0.6<br />
28.0±0.6<br />
28.5±0.6<br />
17.0±0.4<br />
25.4±0.6<br />
28.5±0.6<br />
28.5±0.6<br />
35.0±0.8<br />
28.0±0.6<br />
29.0±0.6<br />
28.57±0.6<br />
28.0±0.7<br />
28.5±0.6<br />
28.57±0.6<br />
C<br />
8.5±0.25<br />
5.6±0.25<br />
5.6±0.2<br />
4.88±0.2<br />
8.0±0.3<br />
7.9±0.3<br />
6.35±0.25<br />
6.35±0.3<br />
6.35±0.3<br />
7.0±0.3<br />
8.0±0.3<br />
10.5±0.4<br />
8.0±0.3<br />
6.99±0.3<br />
7.87±0.3<br />
7.0±0.3<br />
9.0±0.3<br />
8.0±0.3<br />
9.0±0.3<br />
8.76±0.3<br />
9.5±0.3<br />
10.7±0.4<br />
9.5±0.3<br />
10.0±0.4<br />
13.0±0.4<br />
12.83±0.4<br />
13.0±0.4<br />
14.0±0.4<br />
13.77±0.4<br />
Impedance (Ω)<br />
25MHz 100MHz<br />
43<br />
76<br />
108<br />
154<br />
137<br />
224<br />
145<br />
224<br />
30<br />
74<br />
30<br />
74<br />
97<br />
158<br />
89<br />
150<br />
134<br />
211<br />
106<br />
196<br />
106<br />
162<br />
30<br />
68<br />
91<br />
151<br />
146<br />
206<br />
108<br />
163<br />
126<br />
180<br />
110<br />
199<br />
110<br />
163<br />
70<br />
130<br />
118<br />
182<br />
106<br />
174<br />
98<br />
148<br />
136<br />
288<br />
103<br />
172<br />
77<br />
152<br />
109<br />
179<br />
96<br />
152<br />
133<br />
197<br />
133<br />
197<br />
21<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
FILTERING<br />
ROUND CABLE FERRITES<br />
Features<br />
- Employ high-performance Ferrites<br />
(Nickel-Zinc). Particularly suitable<br />
for high frequency noise.<br />
- Typically wound with two or three turns<br />
of cable. The impedance ratio is<br />
actually proportional to the square<br />
of the turn.<br />
- Can be installed in its intended location<br />
before product assembly.<br />
Applications<br />
- Superior suppression of radiation<br />
emissions for full compliance with<br />
FCC, VDE and VCCI on Interface/ data<br />
line cables of computers,<br />
peripheral/terminal equipment.<br />
A<br />
C<br />
Unit: mm<br />
Impedance (Ω) 1 turn<br />
Part No. A B C 25MHz 100MHz<br />
TR 3.5-1.3-5 3.5±0.15 5.0±0.3 1.3±0.15 29 48<br />
TR 5.65-3.0-9.8 5.65±0.25 9.8±0.4 3.0±0.2 43 77<br />
TR 6-4-10 6.0±0.4 10.0±0.3 4.0±0.2 36 55<br />
TR 7-3-4 7.30±0.25 4.3±0.3 3.3±0.2 24 52<br />
TR 9-5-3 9.0±0.3 3.0±0.2 5.0±0.25 19 44<br />
TR 9-5-8 9.0±0.3 8.0±0.3 5.0±0.25 29 60<br />
TR 9.5-5-5 9.5±0.3 5.0±0.3 5.0±0.25 22 53<br />
TR 10-6-4 10.0±0.3 4.0±0.3 6.0±0.3 22 48<br />
TR 10-5-5 10.0±0.3 5.0±0.3 5.0±0.25 31 59<br />
TR 11-5-9 11.0±0.3 9.0±0.3 5.0±0.25 48 96<br />
TR 12-6-4 12.0±0.3 4.0±0.3 6.0±0.3 24 53<br />
TR 12-7-5.5 12.0±0.3 5.5±0.3 7.0±0.3 26 59<br />
TR 12.5-8-6.3 12.5±0.3 6.35±0.3 8.0±0.3 26 55<br />
TR 12.5-8-12 12.6±0.5 12.0±0.4 8.1±0.4 43 70<br />
TR 13-7-5 13.0±0.4 5.5±0.3 7.0±0.25 34 52<br />
TR 13-7-7 13.0±0.4 7.0±0.4 7.0±0.25 32 64<br />
TR 13-7-12.7 13.0±0.3 12.7±0.4 7.1±0.3 50 86<br />
TR 14.5-10-8 14.5±0.4 8.0±0.3 10.2±0.4 24 62<br />
TR 15.8-7.8-14.2 15.88±0.4 14.27±0.4 7.87±0.3 82 131<br />
TR 16-12-8 16.0±0.4 8.0±0.3 12.0±0.4 20 53<br />
TR 16-9-12 16.0±0.4 12.0±0.4 9.0±0.3 43 86<br />
TR 16-8-13 16.5±0.4 13.0±0.4 8.2±0.3 83 143<br />
TR 16-8-16 16.5±0.4 16.0±0.4 8.2±0.3 97 162<br />
TR 16-10-7 16.0±0.4 7.0±0.3 10.0±0.4 29 67<br />
TR 16-10-10 16.0±0.4 10.0±0.4 10.0±0.4 36 66<br />
TR 17.5-9.5-6.3 17.5±0.4 6.35±0.3 9.5±0.3 32 64<br />
TR 17.5-9.5-12.7 17.5±0.4 12.7±0.4 9.5±0.3 48 77<br />
TR 18-10-6 18.0±0.5 6.0±0.3 10.0±0.4 31 66<br />
TR 18.6-10-14.2 18.67±0.5 14.27±0.4 10.16±0.4 79 139<br />
TR 20-10-5 20.5±0.6 5.0±0.3 10.2±0.4 29 52<br />
TR 20-10-10 20.5±0.6 10.0±0.4 10.2±0.4 59 96<br />
TR 22-13.5-6.3 22.5±0.6 6.3±0.4 13.5±0.4 22 58<br />
B<br />
FILTERING<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
22
FILTERING<br />
ROUND CABLE FERRITES<br />
Unit: mm<br />
Impedance (Ω) 1 turn<br />
Part No. A B C 25MHz 100MHz<br />
TR 22-13.5-8 22.0±0.6 8.0±0.3 13.5±0.4 34 82<br />
TR 23-11-14 23.6±0.6 14.0±0.4 11.4±0.4 73 125<br />
TR 25-15-12 25.0±0.6 12.0±0.4 15.0±0.5 43 86<br />
TR 25.4-12.7-6.3 25.4±0.6 6.35±0.3 12.7±0.4 39 80<br />
TR 28-16-13 28.0±0.6 13.0±0.4 16.0±0.5 58 96<br />
TR 28-16-20 28.0±0.8 20.0±0.5 16.0±0.5 77 145<br />
TR 29-19-7.5 29.0±0.6 7.5±0.3 19.0±0.5 31 80<br />
TR 31-19-8 31.0±0.8 8.0±0.3 19.0±0.5 34 66<br />
TR 31-19-16 31.0±0.8 16.0±0.4 19.0±0.5 58 96<br />
TR 36-25-7 36.0±0.8 7.0±0.3 25.0±0.6 28 76<br />
TR 40-27-15 40.6±1.0 15.0±0.4 27.4±0.6 43 96<br />
TR 61.4-36-12.8 61.4±1.3 12.8±0.4 36.0±0.75 38 91<br />
GRAPHIC DATA OF RI AND TR CORES<br />
23<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
FILTERING<br />
ROUND CABLE FERRITES<br />
FILTERING<br />
RI 11-20-5<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
24
FILTERING<br />
ROUND CABLE FERRITES<br />
25<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
FILTERING<br />
ROUND CABLE FERRITES<br />
FILTERING<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
26
FILTERING<br />
ROUND CABLE FERRITES<br />
27<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
FILTERING<br />
FINEMET CORE (F)<br />
Features<br />
- Toroidal cores employing FINEMET, nanocrystalline soft<br />
magnetic material<br />
- High impedance can be obtained in MHz frequency band<br />
and under.<br />
- FINEMET has very high Curie temperature (570°C) which<br />
results in stable magnetic characteristics at high temperature<br />
range.<br />
- As FINEMET has high saturation magnetic flux denstiy,<br />
three times higher than ferrite cores, superior suppresssion<br />
of spike current is possible with smaller cores.<br />
FILTERING<br />
B<br />
A<br />
C<br />
F3724E<br />
Unit: mm<br />
Part No.<br />
F2515D<br />
F3320E<br />
F3724E<br />
F4424G<br />
F4535G<br />
F6045G<br />
F7555G<br />
A<br />
28.0<br />
35.8<br />
40.0<br />
46.5<br />
49.0<br />
64.0<br />
79.0<br />
B<br />
12.8±0.5<br />
17.3±0.5<br />
21.1±0.5<br />
21.5±0.5<br />
31.0±0.5<br />
41.0±0.7<br />
51.0±0.7<br />
C<br />
16.8<br />
17.5<br />
17.6<br />
22.8<br />
25.0<br />
25.0<br />
25.0<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
28
FILTERING<br />
LOW CUT CORE (TRM)<br />
Features<br />
- High impedance character showed in<br />
low frequency noise<br />
- Reduce damage by load to the cable<br />
due to R shape of ridge coated with<br />
epoxy<br />
epoxy coating<br />
Material<br />
- Mn-Zn Soft Ferrite with Epoxy coating<br />
B<br />
A<br />
C<br />
Unit: mm<br />
Part No.<br />
TRM-16-8-16E-WE<br />
TRM-20-10-10E-WE<br />
TRM-25-15-12E-WE<br />
TRM-47-27-15E-WE<br />
A<br />
17 max<br />
21 max<br />
26 max<br />
48.5 max<br />
B<br />
7.1 min<br />
9.1 min<br />
14.1 min<br />
25.7 min<br />
C<br />
16.9 max<br />
10.9 max<br />
12.9 max<br />
16.3 max<br />
Impedance Frequency<br />
Number of turn wire 2T : 2turns<br />
Number of turn wire 2T : 2turns<br />
Impedance (Ω)<br />
TRM-16-8-16E-WE (Z)<br />
TRM-20-10-10E-WE (Z)<br />
Impedance (Ω)<br />
TRM-25-15-12E-WE (Z)<br />
TRM-47-27-15E-WE (Z)<br />
o.01 0.1 1 10 100 1000<br />
Frenquency ( MHz)<br />
o.01 0.1 1 10 100 1000<br />
Frenquency ( MHz)<br />
Comparative Characteristic<br />
Number of turn wire 1T : 1 turn<br />
Number of turn wire 2T : 2turns<br />
Impedance (Ω)<br />
TRM-16-8-16E-WE 1T<br />
TR-16-8-16(Standard) 1T<br />
Impedance (Ω)<br />
TRM-16-8-16E-WE 2T<br />
TR-16-8-16(Standard) 2T<br />
o.01 0.1 1 10 100 1000<br />
Frenquency ( MHz)<br />
o.01 0.1 1 10 100 1000<br />
Frenquency ( MHz)<br />
29<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
FILTERING<br />
ROUND CABLE FERRITES<br />
Features<br />
- Employ high-performance Ferrites<br />
(Nickel-Zinc). Particularly suitable<br />
for high frequency noise.<br />
- Typically wound with two or three turns<br />
of cable. The impedance ratio is<br />
actually proportional to the square<br />
of the turn.<br />
- Can be installed in its intended location<br />
before product assembly.<br />
A<br />
C<br />
B<br />
D<br />
Applications<br />
- Superior suppression of radiation<br />
emissions for full compliance with<br />
FCC, VDE and VCCI on Interface/ data<br />
line cables of computers,<br />
peripheral/terminal equipment.<br />
E<br />
FILTERING<br />
Part No.<br />
TRE-14-12,5-8<br />
TRE-14-14-8<br />
A<br />
10<br />
10<br />
B<br />
4<br />
4<br />
Unit: mm<br />
C<br />
14<br />
14<br />
D<br />
8<br />
8<br />
E<br />
12,5<br />
14<br />
Impedance (Ω) 1 Turn<br />
25MHz 100MHz<br />
35 66<br />
40 72<br />
Impedance (Ω) 2 Turn<br />
25MHz 100MHz<br />
140 236<br />
158 256<br />
Multi-Aperture wound beads<br />
Typ 1 Typ 2<br />
Part No.<br />
FH8-10.88-5.49-10S<br />
FH6-7.62-5.08-10S<br />
A<br />
10.88<br />
7.62<br />
B<br />
5.49<br />
5.08<br />
C<br />
10.0<br />
10.0<br />
D<br />
5.8<br />
3.8<br />
E<br />
2.54<br />
2.54<br />
F<br />
1.20 max<br />
1.20 max<br />
G<br />
0.4<br />
0.4<br />
25MHz<br />
160<br />
216.3<br />
100MHz<br />
240<br />
241.9<br />
Type<br />
1<br />
2<br />
Rated current<br />
Working temperature<br />
6A<br />
-25°~+85°C<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
30
FILTERING<br />
FERRITE PLATES FOR D-SUB AND CPU<br />
Features<br />
- EMI suppression is achieved by simply<br />
inserting the D sub-plate on the pins of<br />
the connector.<br />
- Space-savings is achieved due to<br />
being integrated in the connector.<br />
- Compared with the bead cores, the<br />
number of parts are reduced.<br />
Applications<br />
- Noise suppression components for<br />
connectors, D sub-type connectors for<br />
CRT, mouse, RS232C interface of<br />
computer, etc.<br />
Part No.<br />
FH9-14.5-7.6-2.8<br />
FH15-22.65-7.6-2.8<br />
FH25-36.4-7.6-2.8<br />
FH37-53.08-7.7-2.8<br />
A<br />
14.5<br />
22.65<br />
36.4<br />
53.08<br />
B<br />
7.6<br />
7.6<br />
7.6<br />
7.7<br />
Unit: mm<br />
C<br />
2.8<br />
2.8<br />
2.8<br />
2.8<br />
D<br />
2.74<br />
2.77<br />
2.77<br />
2.77<br />
E<br />
2.84<br />
2.84<br />
2.84<br />
2.84<br />
øF<br />
1.57<br />
1.57<br />
1.57<br />
1.5<br />
Number<br />
of holes<br />
9<br />
15<br />
25<br />
37<br />
Impedance (Ω)<br />
25MHz 100MHz<br />
35 64<br />
34 65<br />
33 64<br />
34 65<br />
Application<br />
for D sub-connector<br />
for D sub-connector<br />
for D sub-connector<br />
for D sub-connector<br />
CPU-core<br />
Features<br />
- Thermally conductive ferrite plates<br />
designed for EMI absorption for ICs,<br />
CPUs and busdrives running at high<br />
clock speed.<br />
- Reduced thickness (0,8 mm) and<br />
excellent thermal conductivity characteristics<br />
allow the tile to be inserted<br />
between CPU and heart sink providing<br />
EMI shielding without affecting<br />
the heat dissipation process.<br />
- The ferrite tiles are available in standard<br />
(as shown), customized sizes<br />
and are optionally supplied with<br />
thermally-conductive adhesive transfer<br />
tape for convenient fastening.<br />
A<br />
B<br />
C<br />
Part No.<br />
SD-28-28-0,8 *<br />
SD-38-38-2 *<br />
A<br />
28,0<br />
38,0<br />
Unit: mm<br />
B<br />
28,0<br />
38,0<br />
C<br />
0,8<br />
2,0<br />
*Thermal transfer<br />
tape optional (-T)<br />
31<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
FILTERING<br />
WOUND<br />
BEADS<br />
Applications<br />
- The R6H type wide-band chokes are<br />
mainly used in PC boards to filter the<br />
EMI from outside sources.<br />
1<br />
2<br />
3<br />
1.5 Ts<br />
2 Ts<br />
2.5 Ts<br />
4<br />
3 Ts<br />
Part No.<br />
R6H-Type<br />
R6H 6-10-0.85-1.5TS<br />
R6H 6-10-0.85-2TS<br />
R6H 6-10-0.85-2.5TS<br />
R6H 6-10-0.85-3TS<br />
R6H 6-10-0.85-2x1.5TS<br />
A<br />
6.0±0.25<br />
6.0±0.25<br />
6.0±0.25<br />
6.0±0.25<br />
6.0±0.25<br />
5<br />
Unit: mm<br />
B<br />
10.0±0.4<br />
10.0±0.4<br />
10.0±0.4<br />
10.0±0.4<br />
10.0±0.4<br />
øC<br />
0.5<br />
0.5<br />
0.5<br />
0.5<br />
0.5<br />
2 x 1.5 Ts<br />
Impedance (Ω)<br />
25MHz 100MHz<br />
390<br />
510<br />
690<br />
860<br />
340<br />
460<br />
580<br />
680<br />
750<br />
450<br />
Fig.<br />
1<br />
2<br />
3<br />
4<br />
5<br />
FILTERING<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
32
FILTERING<br />
WOUND<br />
BEADS<br />
Features<br />
- Ferrite beads are used to remove high<br />
frequency noise.<br />
- Are supplied taped, suitable for<br />
automatic insertion into p.c. boards.<br />
- Rated current 6A<br />
Applications<br />
- Noise suppression of on-board<br />
components of personal computer,<br />
word processor, facsimile and other<br />
digital equipment.<br />
Rated current<br />
Working temperature<br />
6A<br />
-25°~+85°C<br />
Part No.<br />
RH 3.5-4.7-0.8<br />
RH 3.5-6.0-0.8<br />
RH 3.5-7.5-0.8<br />
RH 3.5-8.0-0.8<br />
RH 3.5-9.0-0.8<br />
A<br />
3.5<br />
3.5<br />
3.5<br />
3.5<br />
3.5<br />
Unit: mm<br />
B<br />
4.7<br />
6.0<br />
7.5<br />
8.0<br />
9.0<br />
øC<br />
0.65<br />
0.65<br />
0.65<br />
0.65<br />
0.65<br />
25MHz<br />
52<br />
57<br />
91<br />
88<br />
97<br />
Impedance (Ω)<br />
100MHz<br />
82<br />
84<br />
111<br />
138<br />
117<br />
33<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
FILTERING<br />
WOUND<br />
BEADS<br />
Part No.<br />
Rated current<br />
Working temperature<br />
RH 3.5-6.0-0.8-DT<br />
RH 3.5-6.0-0.8-AT<br />
6A<br />
-25°C-85°C<br />
RH 3.5-6.0-0.8-DT<br />
A 3.5±0.15<br />
B 6.0±0.3<br />
C 12.7±-0.3<br />
D 5.0±-1.0<br />
E 18.0±-1.0<br />
unit:mm<br />
RH 3.5-6.0-0.8-AT<br />
E<br />
C<br />
D<br />
A<br />
B<br />
FILTERING<br />
A 3.5±0.15<br />
B 6.0±0.3<br />
C 12.7±1.5<br />
D 5.0±0.5<br />
E 16.5±1.0<br />
unit:mm<br />
E<br />
A<br />
C<br />
D<br />
FERRITE DESIGN KIT ESF-10K<br />
Part No.<br />
Quantity<br />
USB-4 2<br />
SFC-5 2<br />
SFC-6 2<br />
SFC-8 2<br />
SFC-10 2<br />
RFC-5 2<br />
RFC-6 2<br />
RFC-8 2<br />
RFC-9 2<br />
RFC-10 2<br />
RFC-13 2<br />
RI-11-25-5 3<br />
RI-14.2-28.5-6.4 3<br />
RI-16-28-7 3<br />
RI-16-28.5-8 3<br />
RI-16-28-9 3<br />
RI-18-28-10 3<br />
RI-26-28-13 3<br />
TR-16-8-13 3<br />
TR-16-8-16 3<br />
TR-20-10-10 3<br />
Part No.<br />
Quantity<br />
TR-25-15-12 3<br />
TR-28-16-20 3<br />
TR-40-27-15 1<br />
TFC-16-8-16 2<br />
TFC-23-11-14 2<br />
TFC-25-15-12 2<br />
TRCN-28-16-13 1<br />
TRCN-28-16-20 1<br />
TRCN-40-27-15 1<br />
SSC-33.5-12 2<br />
SSC-40-12 2<br />
SSC-45-12 2<br />
SSC-50-12 2<br />
SSC-58-12 2<br />
FP-38-6.35-25.4 1<br />
FP-45-6.35-28.5 1<br />
FP-63-6.35-28.5 1<br />
BCN-50 1<br />
R6H-6-10-0.85-2.5Ts 5<br />
Samples of foam gaskets.<br />
ESF-10K<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
34
FILTERING<br />
ABSORBING SHEET MG-Series<br />
Features<br />
MG-0.3A<br />
- Noise absorption sheet composed of<br />
heat-resistant rubber mixed with<br />
highly permeable metal magnetic<br />
material.<br />
- Can be used and shows effectiveness<br />
in a high-temperature environment<br />
up to 150°C; in-vehicle equipment or<br />
periphery of CPU in electronics.<br />
- Neither chlorine(CI)- nor bromine(Br)-<br />
based materials are used.<br />
Characteristics<br />
Thickness (mm)<br />
Operating Temperature (C°)<br />
Volume Resistivity (Ω cm)<br />
Flammability Rating<br />
Material<br />
Feature<br />
Transmission Loss<br />
MG-04<br />
- Sheet thickness: 0.05mm and 0.1mm<br />
- Flexible and easy to install<br />
- With the improved magnetic property,<br />
MG-04 is effective for noise control.<br />
MG-05/MG-06<br />
- High permeabilliy which realizes<br />
excellent performances in noise<br />
supression effect<br />
- Satisfies UL standards.<br />
MG-03A<br />
0.5/1.0<br />
-40 °C ~ +150°C<br />
10 7<br />
UL 94-HB<br />
(equivalent)<br />
Magnetic Metal<br />
Filler+Rubber<br />
Improved Heat<br />
Resistance<br />
- Can easily be cut into any desired<br />
shape.<br />
MG-04 MG-05 MG-05A MG-06 MG-06A<br />
10 7 10 11 10 10<br />
0.05/0.1 0.1 0.25/0.5 0.1 0.25/0.5<br />
-25 °C ~+80 °C<br />
-40°C~+85°C<br />
Ultra Thin, High<br />
Permeability<br />
Reflection Loss<br />
UL94-V-O<br />
Magnetic Metal Filler+Rubber<br />
Super High<br />
Permeability<br />
(μ=50/10MHz)<br />
Super High Permeability<br />
(μ=80/10MHz)<br />
Permeability<br />
Trancemittance (dB) Trancemittance (dB) Trancemittance (dB)<br />
Frenquency ( GHz)<br />
0 1 2 3 4 5<br />
MG-03A(t=1mm)<br />
MG-03A(t=0.5mm)<br />
MG-04(t=0.1mm)<br />
Frenquency ( GHz)<br />
0 1 2 3 4 5<br />
MG-05A(t=0.5mm)<br />
MG-05A(t=0.25mm)<br />
MG-05(t=0.1mm)<br />
Frenquency ( GHz)<br />
0 1 2 3 4 5<br />
MG-06A(t=0.5mm)<br />
MG-06A(t=0.25mm)<br />
MG-06(t=0.1mm)<br />
Reflectivity (dB) Reflectivity (dB) Reflectivity (dB)<br />
0 1 2 3 4 5<br />
MG-03A(t=1mm)<br />
MG-03A(t=0.5mm)<br />
MG-04A(t=0.1mm)<br />
Frenquency ( GHz)<br />
0 1 2 3 4 5<br />
MG-05A(t=0.5mm)<br />
MG-05A(t=0.25mm)<br />
MG-05(t=0.1mm)<br />
Frenquency ( GHz)<br />
0 1 2 3 4 5<br />
MG-06A(t=0.5mm)<br />
MG-06A(t=0.25mm)<br />
MG-06(t=0.1mm)<br />
100<br />
50<br />
0<br />
100<br />
50<br />
MG-03A µ’<br />
MG-03A µ’’<br />
MG-04 µ’<br />
1 10 100 1000<br />
MG-04 µ’’<br />
MG-05A,-05 µ’<br />
MG-05A,-05 µ’’<br />
MG-06A,-06 µ’<br />
0<br />
1 10 100 1000<br />
Measurement method<br />
Measurement method<br />
35<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
FILTERING<br />
ABSORBING SHEET MAB-03<br />
Features<br />
-Highly flexible electromagnetic wave<br />
absorbing sheet, bend-resistant and thin<br />
type<br />
-Suitable for CPU, round cable and chassis<br />
to reduce EMI noise<br />
-Flexible and easy to cut<br />
-Customised die cut is available<br />
Applications<br />
For prevention of radiated EMI noise of<br />
electronic equipment.<br />
For mobile applications such as cellphones,<br />
PDA ect...<br />
Characteristics<br />
Magnetic Material<br />
Thickness (mm)<br />
Operating Temperature (°C)<br />
Volume Resistivity (ohm cm)<br />
Dieelectric Strength (kV)<br />
Flammability Rating<br />
MAB-03<br />
Soft Ferrit<br />
0.4 1.0 2.0 4.0<br />
-25 °C +80 °C<br />
10 12<br />
9(t=0.4mm)<br />
equivalent to UL 94-VO<br />
(for t=4.0mm)<br />
FILTERING<br />
ABSORBING SHEET MAGNEFILM (MFM)<br />
Features<br />
Effective for Leakage Magnetic Flux and<br />
Electromagnetic Wave in Low-frequency<br />
Band<br />
- Effective for leakage magnetic flux and<br />
radiation noise from IC, etc. for which<br />
conventional absorption sheets are not<br />
very effective.<br />
- All around the magnetic foil is laminated<br />
with PET film*<br />
- Stable effectiveness with no rust or crack<br />
coused during use. Easy mounting with<br />
the adhesive backing<br />
Part number MFM-1-0.2-012012T MFM-1-0.2-020020T<br />
Size(mm) 12x12(magnetic foil) 14x14(laminate) 20x20(magnetic) 22x22(laminate)<br />
Thickness (mm)<br />
0.2 (incl. adhesive)<br />
Permeablitiy (10MHz) 65<br />
Adhesive peel strength (N/20mm) 7<br />
Number of Layer Measurement value Attenuation<br />
Without 4.78mT -<br />
1 3.39mT 29%<br />
2 2,14mT 55%<br />
Resistance (Ω)<br />
100<br />
10<br />
MAGNEFILM<br />
Absorption sheet<br />
Cable (no shielding)<br />
MFM (12mm x 12mm)<br />
1<br />
10 100 1000<br />
Frequency(MHz)<br />
*Please keep in mind that MAGNEFILM does not guarantee insulation.<br />
*The data above are central values, not guaranteed performance.<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
36
GROUNDING<br />
FRAME GROUNDING SPACER<br />
The grounding function is combined<br />
with resin-made spacer.<br />
(PATENTED)<br />
Resin made spacer combined with tin<br />
plated phosphor bronze is used for suppression<br />
of EMI and ESD on the PCB.<br />
Specifications:<br />
- Material Resin Part Polyphenylene<br />
ether<br />
Metallic Part<br />
Tin plated<br />
phosphor<br />
bronze<br />
- UL standard (resinpart) UL94V-O<br />
- Contact resistance 10 -2 ~10 -4 Ω<br />
Features<br />
-Pressure devel0ped by plastic and<br />
metal fingers provide contact over p.c.<br />
card for excellent electrical current<br />
passage.<br />
- Stable contact resistance is gained.<br />
- Contact resistance does not vary in<br />
the heat cycle test.<br />
- Even if the screw can not stand at the<br />
center of the PCB, the ground can be<br />
provided as desired.<br />
- Maintenance can be carried out easily.<br />
- The number of parts is reduced.<br />
- The cost is reduced considerably.<br />
Part No.<br />
<strong>FG</strong>S-3S<br />
<strong>FG</strong>S-4S<br />
<strong>FG</strong>S-6S<br />
<strong>FG</strong>S-8S<br />
<strong>FG</strong>S-9S<br />
A<br />
9.8<br />
11.4<br />
14.4<br />
17.7<br />
20.0<br />
Unit: mm<br />
B<br />
20.3<br />
21.9<br />
24.9<br />
28.2<br />
30.5<br />
<strong>FG</strong> EDGE SPACER (<strong>FG</strong>ES-10)<br />
<strong>FG</strong> edge spacer<br />
A grounding function is added to the<br />
supporting structure as well as<br />
open/close functions of the printed circuit<br />
board. Frame grounding can be<br />
taken from the P.C.board spacer in the<br />
equipment which requires opening/closing<br />
of the P.C.board during<br />
maintenance.<br />
Specifications<br />
-Material:<br />
Resin portion: PPHOX<br />
Metal portion: tin plated phosphor<br />
bronze<br />
-Applicable board thickness:<br />
PC board 1.6mm<br />
Chassis side t 0.8mm-t 2.3mm<br />
Features<br />
-Fire-resistant material is used (equivalent<br />
to UL94V-0)<br />
Article No. <strong>FG</strong>ES-10<br />
PWB side t=1.6±0.15 chassis side t=0.8~2.3<br />
*Remarks:<br />
Two installation holes are placed<br />
on the same axis.<br />
37<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
GROUNDING<br />
GROUNDING<br />
CLAMP/RAIL<br />
Features<br />
- Flexible moulded clamps conform to<br />
the irregularities on cable grounding<br />
contact<br />
- The power cable simultaneously<br />
fastened and grounded.<br />
- Since it is made of resin, it is excellent<br />
in elasticity. Therefore, the cable is not<br />
damaged.<br />
- Light-wight, excellent serviceability<br />
and safety.<br />
- Screw mounting method<br />
Specifications<br />
- Clamp material Nylon 6/6 (UL 94 V-0)<br />
- Electrically conductive material Copper<br />
- Mounting method Screw type (M3+ M4)<br />
The grounding function is combined<br />
with the resin made clamp.<br />
The ground clamp is not only fastens<br />
shielding cable, signal cable of various<br />
electrical equipment and devices, but<br />
also takes a grounding effect. Differing<br />
from existing metallic products, the new<br />
product is made of resin compounds.<br />
Therefore, it has proper elasticity and<br />
can be suitably fitted to the cable, thus<br />
excellent grounding is achieved.<br />
Part No.<br />
<strong>FG</strong>C-3 M3<br />
<strong>FG</strong>C-3 M4<br />
<strong>FG</strong>C-5 M3<br />
<strong>FG</strong>C-5 M4<br />
<strong>FG</strong>C-8 M3<br />
<strong>FG</strong>C-8 M4<br />
A<br />
ø3.5<br />
ø3.5<br />
ø6.0<br />
ø6.0<br />
ø9.6<br />
ø9.6<br />
<strong>FG</strong> GUIDE RAIL/ <strong>FG</strong>R-80WSP<br />
Features<br />
- Pressure developed by spherical metal<br />
finger provide contact over P.C. card for<br />
excellence electrical curreent passage.<br />
- Molded guide rail provide rigid guides<br />
to metal finger, P.C. card and chassis<br />
accordingly<br />
- Snap-in rivet mounting method<br />
B<br />
9.5<br />
9.5<br />
10.7<br />
10.7<br />
12.2<br />
12.2<br />
Unit: mm<br />
C<br />
3.2<br />
3.2<br />
4.4<br />
4.4<br />
6.0<br />
6.0<br />
Specifications<br />
Resin portion: Polycarbonate(UL94V-2)<br />
Metal finger portion: Phosphor copper<br />
tin coating<br />
D<br />
18.0<br />
18.0<br />
20.8<br />
20.8<br />
25.2<br />
25.2<br />
Applicable diameter<br />
ø3~ø3.5<br />
ø3~ø3.5<br />
ø5~ø5.5<br />
ø5~ø5.5<br />
ø8~ø8.5<br />
ø8~ø8.5<br />
GROUNDING<br />
A<br />
B<br />
Part No. A B<br />
<strong>FG</strong>R-80WSP 70 80<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
38
GROUNDING<br />
GROUNDING<br />
CLAMP<br />
Features:<br />
- The NK-NS Series is a highly flexible and lightweight<br />
cable clamp made of PA 6.6 (UL 94-V2)<br />
with a pure silvercoating.<br />
- Round form- no sharp edges to damage cables<br />
- Screw mounting method<br />
H<br />
A<br />
G<br />
H<br />
A<br />
G<br />
H<br />
A<br />
E<br />
G<br />
Inner diameter<br />
Diameter<br />
Outer Center Inner<br />
Part No. Type hole hole hole A B C D E F G H N<br />
NK-2NS 3.0 ––– ––– 3.3 4.3 9.5 ––– ––– 4.8 4.8 1.1 9.5<br />
NK-3NS 4.6 ––– ––– 5.3 4.3 10.3 ––– ––– 4.8 4.8 1.1 9.5<br />
NK-4NS 5.6 ––– ––– 6.8 4.3 11.1 ––– ––– 4.8 4.8 1.1 9.5<br />
NK-5NS 7.4 ––– ––– 8.4 4.3 11.9 ––– ––– 4.8 4.8 1.1 9.5<br />
NK-6NS 10.0 ––– ––– 10.6 4.3 12.7 ––– ––– 4.8 6.3 1.1 9.5<br />
NK-7NS 10.7 ––– ––– 12.2 4.3 13.5 ––– ––– 4.8 6.3 1.1 9.5<br />
NK-8NS 11.9 ––– ––– 13.2 4.3 14.3 ––– ––– 4.8 6.3 1.1 9.5<br />
NK-9NS 13.5 ––– ––– 15.2 4.3 15.1 ––– ––– 4.8 6.3 1.1 9.5<br />
NK-10NS 14.0 ––– ––– 16.0 4.3 15.9 ––– ––– 4.8 6.3 1.1 9.5<br />
NK-11NS 16.8 ––– ––– 19.0 5.1 17.5 ––– ––– 6.3 7.9 1.8 12.7<br />
NK-12NS 17.8 ––– ––– 19.8 5.1 18.2 ––– ––– 6.3 7.9 1.8 12.7<br />
NK-13NS 20.8 ––– ––– 22.1 5.1 19.0 ––– ––– 6.3 7.9 1.8 12.7<br />
NK-14NS 21.3 ––– 18.5 22.9 5.1 19.8 11.9 ––– 6.3 7.9 1.8 12.7<br />
NK-16NS B 24.4 ––– 22.3 26.9 5.1 21.4 13.5 ––– 6.3 7.9 1.8 12.7<br />
NK-18NS 26.7 ––– 24.1 29.2 5.1 23.0 15.1 ––– 6.3 7.9 1.8 12.7<br />
NK-24NS 37.3 35.0 31.2 39.4 5.1 27.8 19.8 11.9 6.3 9.5 1.8 12.7<br />
NK-32NS C 51.0 46.2 43.7 52.1 5.1 34.1 24.6 13.5 6.3 9.5 1.8 12.7<br />
MOQ 500pcs<br />
HIGH POINT CONTACT (HPC)<br />
Features:<br />
- Special profile allows the contact<br />
inter-distance to vary from 10 to 20<br />
mm.<br />
- Space saving as there is no change<br />
in spring length when compressed.<br />
- Easy to assemble by screw or adhesive<br />
tape.<br />
Matereial:<br />
- stainless (SUS304/t = 0.15 mm)<br />
Installation:<br />
- Screw M3 / Addhesive tape<br />
Part No.<br />
HPC-10-20T<br />
HPC-10-20<br />
Specification<br />
with dahesive tape<br />
without adhesive tape<br />
22<br />
25<br />
10<br />
39<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
GROUNDING<br />
GROUNDING<br />
MESH/STRAPS<br />
Features<br />
- Excellent impedance characteristics at<br />
high frequencies.<br />
- Thin and flexible aids installation.<br />
- Other Length up to 400mm are<br />
available. Please ask our sales department.<br />
Specifications<br />
- Wire mesh diameter ø0.12 mm<br />
- Wire mesh material tin plated<br />
copper<br />
- Insulation tube resin polyolefine<br />
material<br />
- Connection terminals R2-3<br />
(for M3)<br />
Part No.<br />
<strong>FG</strong>M-50<br />
<strong>FG</strong>M-100<br />
<strong>FG</strong>M-150<br />
<strong>FG</strong>M-200<br />
A<br />
50<br />
100<br />
150<br />
200<br />
Unit: mm<br />
B<br />
8<br />
8<br />
8<br />
8<br />
<strong>FG</strong>C FEHLT<br />
C<br />
2<br />
2<br />
2<br />
2<br />
Features<br />
- Low Impedance ground paths at RF<br />
frequencies.<br />
- Lightweight and very flexible. The<br />
lightweight eases strain relief requirements,<br />
while the flexibility eases<br />
strap routing during assembly.<br />
Specifications<br />
Metal part:<br />
Insulating part:<br />
Screw type:<br />
copper sheet<br />
(100μM)<br />
PVC<br />
(noncombustible)<br />
M3, M4 (Screw not<br />
included)<br />
GROUNDING<br />
Part No.<br />
<strong>FG</strong>ST-50-10-M3C<br />
<strong>FG</strong>ST-100-10-M3C<br />
<strong>FG</strong>ST-150-10-M3C<br />
<strong>FG</strong>ST-50-10-M4C<br />
<strong>FG</strong>ST-100-10-M4C<br />
<strong>FG</strong>ST-150-10-M4C<br />
A<br />
40<br />
90<br />
140<br />
40<br />
90<br />
140<br />
Unit: mm<br />
B<br />
50<br />
100<br />
150<br />
50<br />
100<br />
150<br />
C<br />
3.1<br />
3.1<br />
3.1<br />
4.1<br />
4.1<br />
4.1<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
40
GROUNDING<br />
ON-BOARD<br />
CONTACTS<br />
Features<br />
- Contact components enable automatic mounting.<br />
Contact components enhance grounding effect<br />
around PCBs (printed circuit boards).<br />
- Supplied with the enboss tape for autoinsertion<br />
assembly.<br />
- Height 1.0mm- 7.0 mm are available.<br />
- Improved spring form.<br />
OG-301012<br />
OG-320816<br />
OG-321022<br />
OG-321610G<br />
OG-340815P<br />
A<br />
B<br />
3.0<br />
1.0<br />
3.2<br />
0.8<br />
3.2<br />
1.0<br />
3.2<br />
1.6<br />
3.4<br />
0.8<br />
C<br />
1.2<br />
1.6<br />
2.2<br />
1<br />
1.5<br />
Metal Thickness<br />
Material<br />
Surface treatment<br />
Packing Quantity<br />
0.08<br />
Phosphor Bronze<br />
Surface Partly Alu<br />
plating on the<br />
underplating Ni<br />
8000<br />
0.12<br />
Phosphor Bronze<br />
Partly Au plating on<br />
the underplating<br />
by Ni<br />
8000<br />
0.12<br />
Phosphor Bronze<br />
Partly Au plating on<br />
the underplating<br />
by Ni<br />
7000<br />
0.08<br />
Stainless steel<br />
Partly Au plating on<br />
the underplating<br />
by Nii<br />
3000<br />
0.08<br />
BeCu<br />
Partly Au plating on<br />
the underplating<br />
by Ni<br />
8000<br />
Dimensions<br />
B<br />
B<br />
B<br />
A<br />
C<br />
C<br />
A<br />
B<br />
C<br />
A<br />
B<br />
C<br />
A<br />
C<br />
A<br />
More technical data upon request<br />
A<br />
B<br />
OG-362550<br />
3.6<br />
2.5<br />
OG-363040<br />
OG-363050<br />
3.6<br />
3<br />
OG-450818<br />
4.5<br />
0.8<br />
OG-453060<br />
OG-453070<br />
4.5<br />
3.0<br />
OG-502620R<br />
5<br />
2.6<br />
C<br />
5.0<br />
4.0 (OG-363040)<br />
5.0 (OG-363050)<br />
1.8<br />
6.0 (OG-453060)<br />
7.0 (OG-453070)<br />
2<br />
Metal Thickness<br />
0.15<br />
0.1<br />
0.12<br />
0.22<br />
0.08<br />
Material<br />
Surface treatment<br />
Phosphor Bronze<br />
Sn reflow plating<br />
BeCu<br />
Ni plating Partly Sn<br />
plating on the<br />
underplating by Ni<br />
BeCu<br />
Partly Au plating on<br />
the underplating<br />
by Ni<br />
Phosphor Bronze<br />
Sn reflow plating<br />
Stainless steel<br />
Partly Au plating on<br />
the underplating<br />
by Ni<br />
Packing Quantity<br />
1000<br />
1000<br />
8000<br />
1500<br />
2000<br />
Dimensions<br />
B<br />
B<br />
C<br />
C<br />
A<br />
C<br />
A<br />
B<br />
C<br />
C<br />
A<br />
A<br />
B<br />
A<br />
B<br />
41<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
GROUNDING<br />
ON-BOARD<br />
CONTACTS<br />
OG-503040<br />
OG-542925<br />
OG-603060<br />
OG-603070<br />
OG-865028<br />
A<br />
B<br />
5<br />
3<br />
5.4<br />
2.9<br />
6.0<br />
3.0<br />
8.6<br />
5.0<br />
C<br />
4<br />
2.5<br />
6.0 (OG-603060)<br />
7.0 (OG-603070)<br />
2.8<br />
Metal Thickness<br />
0.1<br />
0.12<br />
0.12 (OG-603060)<br />
0.08 (OG-603070)<br />
0.08<br />
Material<br />
Surface treatment<br />
Packing Quantity<br />
BeCu<br />
Sn plating<br />
1000<br />
Phosphor Bronze<br />
Partly Au plating on<br />
the underplating<br />
by Ni<br />
5000<br />
Phosphor Bronze<br />
Sn plating<br />
850 (OG-603060)<br />
750 (OG-603070)<br />
Phosphor Bronze<br />
Sn plating<br />
3000<br />
Dimensions<br />
B<br />
C<br />
B<br />
C<br />
C<br />
A<br />
B<br />
A<br />
C<br />
A<br />
A<br />
B<br />
ON BOARD CLAMP/ON BOARD CLIP / ON BOARD SIDE CONTACT<br />
A<br />
B<br />
C<br />
Metal Thickness<br />
OGC-331610<br />
3.3<br />
1.6<br />
1.05<br />
0.15<br />
OGC-311510U<br />
3.1<br />
1.5<br />
1.02<br />
0.12<br />
OGCP-650813*<br />
6.7<br />
0.8<br />
1.28<br />
0.15<br />
OGCP-1182435<br />
11.8<br />
2.4<br />
3.5<br />
0.2<br />
OGSC-756030<br />
7.5<br />
6.0<br />
3<br />
0.12<br />
GROUNDING<br />
Material<br />
Phosphor Bronze<br />
Phosphor Bronze<br />
Titanium copper<br />
Phosphor Bronze<br />
Phosphor Bronze<br />
Surface treatment<br />
Sn plating<br />
Sn plating<br />
Sn plating<br />
Sn reflow plating<br />
on Cu plating<br />
Sn plating<br />
Packing Quantity<br />
3000<br />
3000<br />
8000<br />
3000<br />
2000<br />
Dimensions<br />
A<br />
B<br />
C<br />
C<br />
B<br />
A<br />
A<br />
C<br />
A<br />
C<br />
A<br />
B<br />
B<br />
C<br />
B<br />
*with Gold plating available (with suffix "G")<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
42
GROUNDING<br />
ON-BOARD SOFT CONTACT<br />
Features<br />
- SMD Grounding Components with soft contact (Silicon<br />
with Ag based filler)<br />
- Contact components enable automatic mounting<br />
- Sonftness of conductive elastomer enables superior contact<br />
- Lower impedance at higher frequency range because of<br />
wide surface of contact<br />
- Silicon material causes no damage to plated surface or<br />
conductive paint<br />
Height 5,5mm-7,5mm are available<br />
Resisitance (Ω)<br />
Charactaristic of Compression Resistance<br />
OGSS-483055<br />
0.05<br />
25<br />
Resisitance<br />
Compression Force<br />
0.04<br />
0.03<br />
0.02<br />
0.01<br />
0<br />
20<br />
15<br />
10<br />
5<br />
0<br />
4.5 4.4 4.2 4 3.8 3.6 3.4 3.2<br />
Gap<br />
Compression Force (N)<br />
Impedance (Ω)<br />
Comparison test of Impedance<br />
5<br />
OG-363050<br />
4<br />
OG-483055<br />
3<br />
2<br />
1<br />
0 1 10 100 1000<br />
Frequency<br />
(dimension in mm)<br />
A<br />
B<br />
C<br />
C<br />
(after Compression)<br />
D<br />
Material<br />
Thickness<br />
Material<br />
Surface<br />
treatment<br />
Packing<br />
Quantity<br />
OGSS-483055<br />
5.5<br />
3.2-4.5<br />
2000<br />
OGSS-483065<br />
4.5<br />
4.8<br />
6.5<br />
4.2-5.5<br />
3.0<br />
0.15<br />
Phosphor Bronze<br />
Sn reflow plating on Cu plating<br />
1800<br />
OGSS-483075<br />
7.5<br />
5.2-6.5<br />
1500<br />
Dimensions<br />
C<br />
A<br />
B<br />
D<br />
43<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
2<br />
GROUNDING<br />
ON-BOARD LUG TERMINAL<br />
Features<br />
- To be able to avoid the solder flux<br />
problem<br />
- <strong>FG</strong> terminal to be soldered on the PCB<br />
- Supplied with enboss tape for automatic<br />
chip mounter machine<br />
- Diameter of screw bolt shall be<br />
2.6mm and 3.0 mm<br />
A<br />
B<br />
C<br />
Metal Thickness<br />
Material<br />
Surface treatment<br />
Packing Quantity<br />
OG-R26-SN OG-R30-SN<br />
10.7<br />
12.7<br />
6<br />
8<br />
3<br />
4<br />
0.3<br />
0.3<br />
Tough Pitch copper<br />
Pb-Sn Plating on Cu plating<br />
2000<br />
2000<br />
OG-RM26<br />
6.85<br />
4.7<br />
3<br />
0.4<br />
Brass<br />
8000<br />
OG-RM30 OG-RM30HF<br />
10,4<br />
8<br />
7.6<br />
7.6<br />
4<br />
4<br />
0.3<br />
0,3<br />
Tough Pitch copper<br />
Sn plating on Ni plating<br />
3000<br />
3000<br />
C<br />
C<br />
C<br />
C<br />
C<br />
Dimensions<br />
A<br />
A<br />
A<br />
A<br />
A<br />
B<br />
B<br />
B<br />
B<br />
B<br />
ON-BOARD<br />
PLATE<br />
Metal Thickness<br />
Material<br />
Surface treatment<br />
OGP-3216<br />
0.1<br />
Brass<br />
Au/Ni plating<br />
OGP-4520<br />
0.15<br />
Brass<br />
Sn plating on the<br />
underplaing by Cu<br />
0.3<br />
(0.2)<br />
(2.4)<br />
3.2<br />
1.5<br />
1.6<br />
0.2 ± 0.15<br />
0.05<br />
0.15 ± 0.05<br />
4.5<br />
2<br />
GROUNDING<br />
Packing Quantity<br />
4000<br />
3000<br />
OGP-3216<br />
OGP-4520<br />
ON-BOARD CONTACT ENGINEERING KIT OG-K01/OG-K02T.<br />
On-board contact engineering Kit OG-K01.<br />
Various on-board contacts in a compact case.<br />
OG-K01 (OG series)<br />
OG-K02T (TOG series)<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
44
GROUNDING<br />
ON-BOARD<br />
CONTACTS<br />
Features<br />
- Contact components enable automatic mounting.<br />
Contact components enhance grounding effect<br />
around PCBs (printed circuit boards).<br />
- Supplied with the enboss tape for autoinsertion<br />
assembly.<br />
- Improved spring form.<br />
Dimension in mm<br />
Height: 2.0 - 6.2 mm are available<br />
Material: 0.08 mm Beryllium Copper<br />
Gold plating on Nickel underplating<br />
Nickel (μm) Au (μm)<br />
3.05 0.03<br />
Description<br />
W<br />
T<br />
Original Height H<br />
Final height(mm)- Min<br />
(after compression) Max<br />
Compression Ratio(final/original)<br />
TOG-20-30-25<br />
2.00<br />
3.00<br />
2.50<br />
1.70<br />
2.25<br />
68%~90%<br />
TOG-20-30-40<br />
2.00<br />
3.00<br />
4.00<br />
2.30<br />
3.80<br />
58%~95%<br />
TOG-20-40-20<br />
2.00<br />
4.00<br />
2.00<br />
1.30<br />
1.70<br />
65%~85%<br />
W<br />
W<br />
W<br />
Dimensions<br />
H<br />
H<br />
H<br />
T<br />
T<br />
T<br />
Description<br />
W<br />
T<br />
Original Height H<br />
Final height(mm)- Min<br />
after compression Max<br />
Compression Ratio(final/original)<br />
TOG-20-45-45<br />
2.00<br />
4.50<br />
4.50<br />
3.15<br />
4.00<br />
70%~89%<br />
TOG-20-47-57<br />
2.00<br />
4.70<br />
5.70<br />
2.40<br />
5.10<br />
42%~89%<br />
TOG-20-70-62<br />
2.00<br />
7.00<br />
6.20<br />
3.50<br />
5.50<br />
56%~89%<br />
TOG-25-30-40<br />
2.50<br />
3.00<br />
4.00<br />
2.50<br />
3.60<br />
63%~90%<br />
TOG-20-40-21<br />
2.50<br />
4.00<br />
2.10<br />
1.60<br />
2.00<br />
76%~95%<br />
W<br />
W<br />
W<br />
W<br />
W<br />
Dimensions<br />
H<br />
H<br />
H<br />
H<br />
H<br />
T<br />
T<br />
T<br />
T<br />
T<br />
Description<br />
W<br />
T<br />
Original Height H<br />
Final height(mm)- Min<br />
after compression Max<br />
Compression Ratio(final/original)<br />
TOG-25-40-41<br />
2.50<br />
4.00<br />
4.10<br />
3.80<br />
2.60<br />
63%~93%<br />
TOG-25-40-50<br />
2.50<br />
4.00<br />
5.00<br />
2.00<br />
4.75<br />
40%~95%<br />
TOG-25-40-55<br />
2.50<br />
4.00<br />
5.50<br />
2.80<br />
5.25<br />
51%~95%<br />
TOG-25-45-48<br />
2.50<br />
4.50<br />
4.80<br />
3.00<br />
4.30<br />
63%~90%<br />
TOG-40-40-51<br />
4.00<br />
4.00<br />
5.10<br />
3.10<br />
4.60<br />
61%~90%<br />
W<br />
W<br />
W<br />
W<br />
W<br />
Dimensions<br />
H<br />
H<br />
H<br />
H<br />
H<br />
T<br />
T<br />
T<br />
T<br />
T<br />
45<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
GROUNDING<br />
ON-BOARD<br />
CONTACTS<br />
Features<br />
- Contact components enable automatic<br />
mounting.<br />
Contact components enhance<br />
grounding effect<br />
around PCBs (printed circuit<br />
boards).<br />
- Supplied with the enboss tape for<br />
autoinsertion assembly.<br />
- Improved spring form.<br />
- All products are gold plating on<br />
nickel underplating<br />
Height: 2.15 - 6.2 mm are available<br />
Material: BerylliumCopper<br />
Dimension in mm<br />
Description<br />
W<br />
T<br />
H<br />
Material Thickness<br />
Packing Quantity<br />
FOG-206030<br />
2.00<br />
6.00<br />
3.00<br />
0.08<br />
4000<br />
FOG-203230<br />
2.00<br />
3.20<br />
3.00<br />
0.08<br />
2500<br />
FOG-224021<br />
2.20<br />
4.00<br />
2.15<br />
0.08<br />
3000<br />
FOG-256248<br />
2.50<br />
6.20<br />
4.80<br />
0.10<br />
200<br />
W<br />
W<br />
W<br />
Dimensions<br />
H<br />
H<br />
H<br />
H<br />
T<br />
W<br />
T<br />
T<br />
T<br />
Description<br />
W<br />
T<br />
H<br />
Material Thickness<br />
Packing Quantity<br />
FOG-256866<br />
2.50<br />
6.88<br />
5.32<br />
0.15<br />
1000<br />
FOG-254945<br />
2.50<br />
4.95<br />
4.50<br />
0.15<br />
1500<br />
FOG-255036<br />
2.50<br />
5.00<br />
3.60<br />
0.10<br />
1500<br />
FOG-254143<br />
2.50<br />
4.10<br />
4.29<br />
0.10<br />
1500<br />
Dimensions<br />
H<br />
H<br />
W<br />
H<br />
H<br />
Description<br />
W<br />
T<br />
H<br />
Material Thickness<br />
Packing Quantity<br />
T<br />
FOG-254536<br />
2.50<br />
4.50<br />
3.60<br />
0.10<br />
2000<br />
W<br />
T<br />
FOG-203040<br />
2.00<br />
3.00<br />
4.00<br />
0.10<br />
1500<br />
T<br />
FOG-173936<br />
1.70<br />
3.95<br />
3.60<br />
0.10<br />
1500<br />
W<br />
T<br />
FOG-257062<br />
2.50<br />
7.00<br />
6.20<br />
0.15<br />
1000<br />
W<br />
GROUNDING<br />
Dimensions<br />
T<br />
H<br />
W<br />
W<br />
H<br />
W<br />
H<br />
W<br />
T<br />
H<br />
T<br />
T<br />
Description<br />
W<br />
T<br />
H<br />
Material Thickness<br />
Packing Quantity<br />
FOG-254757<br />
2.50<br />
4.70<br />
5.70<br />
0.10<br />
850<br />
FOG-255542<br />
2.50<br />
5.50<br />
4.20<br />
0.15<br />
1000<br />
FOG-254338<br />
2.50<br />
4.31<br />
3.85<br />
0.10<br />
1500<br />
FOG-204838<br />
2.02<br />
4.81<br />
3.86<br />
0.08<br />
1500<br />
W<br />
Dimensions<br />
W<br />
H<br />
H<br />
H<br />
H<br />
T<br />
T<br />
T<br />
W<br />
T<br />
W<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
46
GROUNDING<br />
CONDUCTIVE<br />
TAPE<br />
Easy application same uses as a transparent<br />
tape. High shielding effectiveness due to highly<br />
conductive adhesive tape. Easy cutout or configuration<br />
for optimum shielding effectiveness.<br />
width (mm)<br />
DIMENSION<br />
Length(m)<br />
10<br />
15<br />
20 33<br />
25<br />
50<br />
Other width available upon request<br />
SUPPORTING BASE<br />
Soft – Copper<br />
Soft – Aluminium<br />
Soft – Copper<br />
doublesided tin-coated<br />
CCT-10-C CCT-10-A CCT-10-CS<br />
CCT-15-C CCT-15-A CCT-15-CS<br />
CCT-20-C CCT-20-A CCT-20-CS<br />
CCT-25-C CCT-25-A CCT-25-CS<br />
CCT-50-C CCT-50-A CCT-50-CS<br />
With masking tape available<br />
Technical Data<br />
Colour original original original<br />
Thickness without adhesive (mm) 0,035 ± 10% 0,050 ± 10% 0,037 ± 10%<br />
Thickness with adhesive (mm) 0,055-0,065 0,080 ± 10% 0,072 ± 10%<br />
Kind of adhesive<br />
Acrylic resin, electrical conductive<br />
Eletrical conductivity
GROUNDING<br />
TECHNICAL ADHESIVE TAPES FOR SPECIAL APPLICATIONS<br />
Features<br />
- Polyamid-fleece, metal-coated, with high-quality acrylic<br />
adhesive and very good conductivity.<br />
- For usage as screening material (EMC). Also available with a<br />
covering on the fleece-side. The covering is used as a protection<br />
in the painting process of casings (e.g. power-switch<br />
boxes). After drying or burn in of powder-base painting<br />
(max. 210°C, 1/2 hour) it can be removed from the fleece. For<br />
electrical contact of EMC-gaskets with the casing. No slitaerial<br />
can appear.<br />
- conductivity of the fleece:
GROUNDING<br />
CONDUCTIVE FABRIC TAPE - CNT<br />
Features<br />
Conductive adhesive is made of mixed metal pastes with the normal adhesive to<br />
improve conductivity. This material has very good effectiveness for EMI shielding<br />
and electric to objects needed conductivity.<br />
Non-dioxin type flame retardent.<br />
Part No. Width(mm) Roll (m)<br />
CNT-10H 10<br />
50<br />
CNT-20H 20<br />
50<br />
CNT-25H 25<br />
50<br />
CNT-50H 50<br />
50<br />
Material<br />
Backing<br />
Adhesive<br />
Conductive Filler<br />
Liner<br />
CF-235 (Rip-Stop)<br />
Conductive Acrylic Adhesive<br />
Nickel Powder<br />
Release Liner Paper<br />
Ni+Cu+Ni<br />
Non-Dioxin type FR<br />
Standard sizes & Appearance<br />
Thickness<br />
Color<br />
Overall<br />
Backing<br />
Adhesive<br />
Release Liner<br />
mm<br />
mm<br />
mm<br />
mm<br />
-<br />
0.14± 0.02<br />
0.1<br />
0.04<br />
0.076<br />
Gray<br />
Dial gage<br />
Dial gage<br />
Dial gage<br />
Dial gage<br />
General Properties<br />
Adhesion<br />
Ball tack<br />
Shielding Effectiveness<br />
Holding Power<br />
Surface Resistance<br />
Electric Resistance<br />
gf/25mm<br />
No.<br />
dB<br />
mm<br />
Ω/cm 2<br />
Ω/cm 2 1000+100<br />
7~9<br />
60~70<br />
No Creep<br />
Less than 0.05<br />
Less than 0.03<br />
JIS Z 0237<br />
JIS Z 0237<br />
ASTM D 4935-89<br />
JIS Z 0237<br />
ISL 2000A<br />
HIOKI 3540<br />
Structure<br />
Conductive Fabric<br />
Conductive Acrylic<br />
Adhesive(non-Dioxin)<br />
Release Liner<br />
49<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
SHIELDING<br />
FABRIC FOAM OVER GAS<strong>KE</strong>T<br />
Features<br />
Broad range of the most advanced and sophisticated EMI<br />
shielding gaskets Effectiveness from 30Mhz to 1Ghz. The Core<br />
of polyurethane foam(which is approved as UL94 HF-1) in<br />
high resiliency provides high elasticity and very good self stability<br />
easy to process and cut. Gold gasket and Black gaskets<br />
are available.<br />
Conductive fabric<br />
Physical Property<br />
Material<br />
PET 100%<br />
Physical Property<br />
Tensil strength<br />
(kgf)<br />
warp<br />
49.7<br />
Plating<br />
Method<br />
Ni+Cu+Ni 73±3 0.1±0.015 128.8 113.4<br />
weft<br />
38.8<br />
warp<br />
23.6<br />
Weight<br />
(g/m 2 )<br />
Extension<br />
(%)<br />
weft<br />
27.9<br />
Thickness Fabric Count(thread/inch)<br />
(mm) wrap weft<br />
Surface<br />
Resistance (Ω/cm 2 )<br />
MIN<br />
0.03<br />
Shielding<br />
Effetiveness(dB)<br />
MAX 30MHz-1GHz<br />
0.05 60 70<br />
Material/Form<br />
PET 100%<br />
Product Cross<br />
Section<br />
Type of Gasket EMI GAS<strong>KE</strong>T EMI GOLD GAS<strong>KE</strong>T EMI BLACK GAS<strong>KE</strong>T<br />
Symbol of fabric for Part.no. VNN GLD BLK<br />
Raw Material of Fabric PET 100% PET 100% PET 100%<br />
Plating Ni+Cu+Ni Ni+Cu+Ni+Au Ni+Cu+Ni+Carbon<br />
Composition Rip stop Taffeta Rip stop<br />
Foam Core (Polturethan eFoam)<br />
UL 94 HF-1<br />
Shielding effectiveness (dB) 80-100 80-100 80-100<br />
Surface resistance (Ω/cm 2 ) less than 0.05 less than 0.03 less than 0.05<br />
Electric resistance (Ω/cm 2 ) less than 0.03 less than 0.02 less than 0.03<br />
Compression Set 30% 30% 30%<br />
Compression load deflection 2 kg 2 kg 2 kg<br />
Flame retardant UL 94-VO N/A N/A<br />
Service Temp. up to 100°C up to 100°C up to 100°C<br />
Advantage Lower Cost price Better Conductivity water-resistant<br />
No Finger Print<br />
Poly Urethane Foam<br />
Material<br />
SFHL - 13<br />
Polyuretthane<br />
Foam<br />
Classification<br />
Density<br />
kg/m 3<br />
25lLD<br />
Ball<br />
Rebound<br />
Tensile<br />
Strength<br />
Tear<br />
Strength<br />
Unit kg/m kg/314cm 2 % kg/cm 2 kg/cm % % m/min<br />
Typical 45±3 30~35 50min Min.1.5 Min. 0.4 Max. 6 Min. 120 pass<br />
values 45.70 34.38 52 1.869 0.877 4.53 122.43 pass<br />
Pressure Sensitive Adhesive(P.S.A)<br />
Specification<br />
Part No<br />
Thickness<br />
Recommended<br />
Operating Temperature<br />
Colour<br />
Standard adhesive (VTM-0)<br />
Nitto 5011N<br />
0.16mm<br />
-20°C to 120°C<br />
white<br />
<strong>KE</strong> KITAGAWA<br />
Compreession<br />
fatigue set<br />
(70m,22hr,50%)<br />
Conductive Adhesive<br />
CMFT-130-D<br />
0.12mm<br />
-20°C to 120°C<br />
Elongation<br />
Flame<br />
retardant<br />
Reference JIS-K-6401 JIS-K-6401 JIS-K-6401 JIS-K-6401 JIS-K-6401 JIS-K-6401 JIS-K-6401 FMVSS-302<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
gray<br />
50<br />
SHIELDING
SHIELDING<br />
FABRIC OVER FOAM GAS<strong>KE</strong>T<br />
Rectangular PROFILE<br />
H<br />
PROFILE NO<br />
<strong>KE</strong>-<strong>FG</strong>-R01<br />
<strong>KE</strong>-<strong>FG</strong>-R02<br />
<strong>KE</strong>-<strong>FG</strong>-R03<br />
<strong>KE</strong>-<strong>FG</strong>-R04<br />
<strong>KE</strong>-<strong>FG</strong>-R05<br />
<strong>KE</strong>-<strong>FG</strong>-R06<br />
<strong>KE</strong>-<strong>FG</strong>-R07<br />
<strong>KE</strong>-<strong>FG</strong>-R08<br />
<strong>KE</strong>-<strong>FG</strong>-R09<br />
<strong>KE</strong>-<strong>FG</strong>-R10<br />
<strong>KE</strong>-<strong>FG</strong>-R11<br />
<strong>KE</strong>-<strong>FG</strong>-R12<br />
<strong>KE</strong>-<strong>FG</strong>-R13<br />
<strong>KE</strong>-<strong>FG</strong>-R14<br />
<strong>KE</strong>-<strong>FG</strong>-R15<br />
<strong>KE</strong>-<strong>FG</strong>-R16<br />
<strong>KE</strong>-<strong>FG</strong>-R17<br />
<strong>KE</strong>-<strong>FG</strong>-R18<br />
<strong>KE</strong>-<strong>FG</strong>-R19<br />
<strong>KE</strong>-<strong>FG</strong>-R20<br />
<strong>KE</strong>-<strong>FG</strong>-R21<br />
<strong>KE</strong>-<strong>FG</strong>-R22<br />
<strong>KE</strong>-<strong>FG</strong>-R23<br />
<strong>KE</strong>-<strong>FG</strong>-R24<br />
<strong>KE</strong>-<strong>FG</strong>-R25<br />
<strong>KE</strong>-<strong>FG</strong>-R26<br />
<strong>KE</strong>-<strong>FG</strong>-R27<br />
<strong>KE</strong>-<strong>FG</strong>-R28<br />
<strong>KE</strong>-<strong>FG</strong>-R29<br />
<strong>KE</strong>-<strong>FG</strong>-R30<br />
<strong>KE</strong>-<strong>FG</strong>-R31<br />
<strong>KE</strong>-<strong>FG</strong>-R32<br />
<strong>KE</strong>-<strong>FG</strong>-R33<br />
<strong>KE</strong>-<strong>FG</strong>-R34<br />
<strong>KE</strong>-<strong>FG</strong>-R35<br />
<strong>KE</strong>-<strong>FG</strong>-R36<br />
<strong>KE</strong>-<strong>FG</strong>-R37<br />
<strong>KE</strong>-<strong>FG</strong>-R38<br />
<strong>KE</strong>-<strong>FG</strong>-R39<br />
<strong>KE</strong>-<strong>FG</strong>-R40<br />
<strong>KE</strong>-<strong>FG</strong>-R41<br />
W<br />
SIZE (WxH)<br />
3.0 X 2.0<br />
4.0 X 2.0<br />
4.0 X 3.0<br />
4.0 X 4.0<br />
4.8 X 3.2<br />
5.0 X 2.0<br />
5.0 X 3.0<br />
5.0 X 4.0<br />
5.0 X 5.0<br />
5.0 X 6.0<br />
5.0 X 7.0<br />
5.5 X 5.5<br />
6.0 X 2.0<br />
6.0 X 3.0<br />
6.0 X 4.0<br />
6.0 X 5.0<br />
6.0 X 6.0<br />
6.0 X 8.0<br />
6.4 X 3.2<br />
6.4 X 4.8<br />
6.4 X 6.4<br />
6.5 X 4.0<br />
6.5 X 6.5<br />
7.0 X 2.0<br />
7.0 X 3.0<br />
7.0 X 4.0<br />
7.0 X 7.0<br />
7.0 X 8.0<br />
8.0 X 2.0<br />
8.0 X 3.0<br />
8.0 X 4.0<br />
8.0 X 5.0<br />
8.0 X 6.0<br />
8.0 X 8.0<br />
8.0 X 10<br />
8.0 X 12<br />
8.0 X 15<br />
9.0 X 2.0<br />
9.0 X 3.0<br />
9.0 X 4.0<br />
9.0 X 5.0<br />
PROFILE NO SIZE (WxH)<br />
<strong>KE</strong>-<strong>FG</strong>-R42 9.0 X 6.0<br />
<strong>KE</strong>-<strong>FG</strong>-R43 9.5 X 3.2<br />
<strong>KE</strong>-<strong>FG</strong>-R44 9.5 X 6.4<br />
<strong>KE</strong>-<strong>FG</strong>-R45 9.5 X 9.5<br />
<strong>KE</strong>-<strong>FG</strong>-R46 10 X 2.0<br />
<strong>KE</strong>-<strong>FG</strong>-R47 10 X 3.0<br />
<strong>KE</strong>-<strong>FG</strong>-R48 10 X 4.0<br />
<strong>KE</strong>-<strong>FG</strong>-R49 10 X 4.5<br />
<strong>KE</strong>-<strong>FG</strong>-R50 10 X 5.0<br />
<strong>KE</strong>-<strong>FG</strong>-R51 10 X 5.5<br />
<strong>KE</strong>-<strong>FG</strong>-R52 10 X 6.0<br />
<strong>KE</strong>-<strong>FG</strong>-R53 10 X 7.0<br />
<strong>KE</strong>-<strong>FG</strong>-R54 10 X 8.0<br />
<strong>KE</strong>-<strong>FG</strong>-R55 10 X 10<br />
<strong>KE</strong>-<strong>FG</strong>-R56 10 X 12<br />
<strong>KE</strong>-<strong>FG</strong>-R57 10 X 13<br />
<strong>KE</strong>-<strong>FG</strong>-R58 10 X 14<br />
<strong>KE</strong>-<strong>FG</strong>-R59 10 X 15<br />
<strong>KE</strong>-<strong>FG</strong>-R60 10 X 17<br />
<strong>KE</strong>-<strong>FG</strong>-R61 10 X 18<br />
<strong>KE</strong>-<strong>FG</strong>-R62 10 X 20<br />
<strong>KE</strong>-<strong>FG</strong>-R63<br />
12 X 2<br />
<strong>KE</strong>-<strong>FG</strong>-R64<br />
12 X 3<br />
<strong>KE</strong>-<strong>FG</strong>-R65<br />
12 X 4<br />
<strong>KE</strong>-<strong>FG</strong>-R66<br />
12 X 6<br />
<strong>KE</strong>-<strong>FG</strong>-R67<br />
12 X 8<br />
<strong>KE</strong>-<strong>FG</strong>-R68 12 X 10<br />
<strong>KE</strong>-<strong>FG</strong>-R69 12 X 12<br />
<strong>KE</strong>-<strong>FG</strong>-R70<br />
13 X 7<br />
<strong>KE</strong>-<strong>FG</strong>-R71<br />
13 X 8<br />
<strong>KE</strong>-<strong>FG</strong>-R72<br />
13 X 9<br />
<strong>KE</strong>-<strong>FG</strong>-R73 13 X 10<br />
<strong>KE</strong>-<strong>FG</strong>-R74 13 X 12<br />
<strong>KE</strong>-<strong>FG</strong>-R75 13 X 13<br />
<strong>KE</strong>-<strong>FG</strong>-R76<br />
15 X 2<br />
<strong>KE</strong>-<strong>FG</strong>-R77<br />
15 X 4<br />
<strong>KE</strong>-<strong>FG</strong>-R78<br />
15 X 5<br />
<strong>KE</strong>-<strong>FG</strong>-R79<br />
15 X 6<br />
<strong>KE</strong>-<strong>FG</strong>-R80 15 X 10<br />
<strong>KE</strong>-<strong>FG</strong>-R81 15 X 15<br />
<strong>KE</strong>-<strong>FG</strong>-R82 16 X 10<br />
<strong>KE</strong>-<strong>FG</strong>-R83 17 X 10<br />
<strong>KE</strong>-<strong>FG</strong>-R84 17 X 15<br />
<strong>KE</strong>-<strong>FG</strong>-R85 17 X 17<br />
<strong>KE</strong>-<strong>FG</strong>-R86 17 X 21<br />
<strong>KE</strong>-<strong>FG</strong>-R87 17 X 25<br />
<strong>KE</strong>-<strong>FG</strong>-R88<br />
18 X 3<br />
<strong>KE</strong>-<strong>FG</strong>-R89 18 X 10<br />
51<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
SHIELDING<br />
FABRIC OVER FOAM GAS<strong>KE</strong>T<br />
PROFILE NO<br />
<strong>KE</strong>-<strong>FG</strong>-R90<br />
<strong>KE</strong>-<strong>FG</strong>-R91<br />
<strong>KE</strong>-<strong>FG</strong>-R92<br />
<strong>KE</strong>-<strong>FG</strong>-R93<br />
<strong>KE</strong>-<strong>FG</strong>-R94<br />
<strong>KE</strong>-<strong>FG</strong>-R95<br />
<strong>KE</strong>-<strong>FG</strong>-R96<br />
<strong>KE</strong>-<strong>FG</strong>-R97<br />
<strong>KE</strong>-<strong>FG</strong>-R98<br />
<strong>KE</strong>-<strong>FG</strong>-R99<br />
<strong>KE</strong>-<strong>FG</strong>-R100<br />
<strong>KE</strong>-<strong>FG</strong>-R101<br />
<strong>KE</strong>-<strong>FG</strong>-R102<br />
<strong>KE</strong>-<strong>FG</strong>-R103<br />
<strong>KE</strong>-<strong>FG</strong>-R104<br />
<strong>KE</strong>-<strong>FG</strong>-R105<br />
<strong>KE</strong>-<strong>FG</strong>-R106<br />
<strong>KE</strong>-<strong>FG</strong>-R107<br />
<strong>KE</strong>-<strong>FG</strong>-R108<br />
<strong>KE</strong>-<strong>FG</strong>-R133<br />
<strong>KE</strong>-<strong>FG</strong>-R175<br />
<strong>KE</strong>-<strong>FG</strong>-R176<br />
<strong>KE</strong>-<strong>FG</strong>-R177<br />
<strong>KE</strong>-<strong>FG</strong>-R179<br />
<strong>KE</strong>-<strong>FG</strong>-R240<br />
<strong>KE</strong>-<strong>FG</strong>-R250<br />
<strong>KE</strong>-<strong>FG</strong>-R260<br />
<strong>KE</strong>-<strong>FG</strong>-R265<br />
<strong>KE</strong>-<strong>FG</strong>-R270<br />
SIZE (WxH)<br />
18 X 15<br />
20 X 6<br />
20 X 7<br />
20 X 9<br />
20 X 10<br />
20 X 12<br />
20 X 14<br />
20 X 16<br />
20 X 20<br />
25 X 10<br />
25 X 12<br />
25 X 25<br />
26 X 12<br />
26 X 17<br />
30 X 4.5<br />
30 X 10<br />
30 X 30<br />
33 X 6<br />
44 X 20<br />
3.0 X 3.0<br />
12.7 X 6.4<br />
12.7 X 3.2<br />
12.7 X 12.7<br />
12.7 X 9.5<br />
<strong>KE</strong>-<strong>FG</strong>-R186 18 X 6<br />
<strong>KE</strong>-<strong>FG</strong>-R194 13 X 10.5<br />
<strong>KE</strong>-<strong>FG</strong>-R200 11.5 X 10.5<br />
<strong>KE</strong>-<strong>FG</strong>-R205 12.7 X 2<br />
<strong>KE</strong>-<strong>FG</strong>-R210 12.7 X 3.7<br />
<strong>KE</strong>-<strong>FG</strong>-R220 15 X 7.5<br />
<strong>KE</strong>-<strong>FG</strong>-R230 25.4 X 9.5<br />
13.5 X 10<br />
25 X 20<br />
10 X 2.5<br />
4.8 X 3.3<br />
2.3 X 2.3<br />
13 X 4<br />
<strong>KE</strong>-<strong>FG</strong>-R280<br />
<strong>KE</strong>-<strong>FG</strong>-R290 2 X 2<br />
<strong>KE</strong>-<strong>FG</strong>-R300<br />
<strong>KE</strong>-<strong>FG</strong>-R310<br />
<strong>KE</strong>-<strong>FG</strong>-R320<br />
<strong>KE</strong>-<strong>FG</strong>-R330<br />
<strong>KE</strong>-<strong>FG</strong>-R340<br />
<strong>KE</strong>-<strong>FG</strong>-R350<br />
20 X 35<br />
19 X 25<br />
6 X 7<br />
10.5 X 11.5<br />
20 X 4<br />
20 X 8<br />
H<br />
FLAT PROFILE<br />
PROFILE NO<br />
<strong>KE</strong>-<strong>FG</strong>-F01<br />
<strong>KE</strong>-<strong>FG</strong>-F02<br />
<strong>KE</strong>-<strong>FG</strong>-F03<br />
<strong>KE</strong>-<strong>FG</strong>-F04<br />
<strong>KE</strong>-<strong>FG</strong>-F05<br />
<strong>KE</strong>-<strong>FG</strong>-F06<br />
<strong>KE</strong>-<strong>FG</strong>-F07<br />
<strong>KE</strong>-<strong>FG</strong>-F08<br />
<strong>KE</strong>-<strong>FG</strong>-F09<br />
<strong>KE</strong>-<strong>FG</strong>-F10<br />
<strong>KE</strong>-<strong>FG</strong>-F11<br />
<strong>KE</strong>-<strong>FG</strong>-F12<br />
<strong>KE</strong>-<strong>FG</strong>-F13<br />
<strong>KE</strong>-<strong>FG</strong>-F14<br />
<strong>KE</strong>-<strong>FG</strong>-F15<br />
<strong>KE</strong>-<strong>FG</strong>-F16<br />
<strong>KE</strong>-<strong>FG</strong>-F17<br />
<strong>KE</strong>-<strong>FG</strong>-F18<br />
<strong>KE</strong>-<strong>FG</strong>-F19<br />
<strong>KE</strong>-<strong>FG</strong>-F20<br />
<strong>KE</strong>-<strong>FG</strong>-F21<br />
<strong>KE</strong>-<strong>FG</strong>-F22<br />
<strong>KE</strong>-<strong>FG</strong>-F23<br />
<strong>KE</strong>-<strong>FG</strong>-F24<br />
<strong>KE</strong>-<strong>FG</strong>-F25<br />
<strong>KE</strong>-<strong>FG</strong>-F26<br />
<strong>KE</strong>-<strong>FG</strong>-F27<br />
<strong>KE</strong>-<strong>FG</strong>-F28<br />
<strong>KE</strong>-<strong>FG</strong>-F29<br />
<strong>KE</strong>-<strong>FG</strong>-F30<br />
<strong>KE</strong>-<strong>FG</strong>-F31<br />
<strong>KE</strong>-<strong>FG</strong>-F32<br />
<strong>KE</strong>-<strong>FG</strong>-F33<br />
<strong>KE</strong>-<strong>FG</strong>-F34<br />
<strong>KE</strong>-<strong>FG</strong>-F35<br />
<strong>KE</strong>-<strong>FG</strong>-F36<br />
<strong>KE</strong>-<strong>FG</strong>-F37<br />
<strong>KE</strong>-<strong>FG</strong>-F38<br />
<strong>KE</strong>-<strong>FG</strong>-F92<br />
<strong>KE</strong>-<strong>FG</strong>-F110<br />
<strong>KE</strong>-<strong>FG</strong>-F120<br />
<strong>KE</strong>-<strong>FG</strong>-F130<br />
W<br />
SIZE (WxH)<br />
2.0 X 1.2<br />
3.0 X 0.3<br />
3.0 X 1.0<br />
3.0 X 1.2<br />
3.0 X 1.5<br />
4.0 X 1.0<br />
4.0 X 1.2<br />
4.0 X 1.5<br />
5.0 X 0.5<br />
5.0 X 1.0<br />
5.0 x 1.2<br />
5.0 x 1.5<br />
5.0 x 1.8<br />
6.0 x 1.0<br />
6.0 x 1.2<br />
6.0 x 1.5<br />
7.0 x 1.0<br />
7.0 x 1.2<br />
7.0 x 1.5<br />
7.0 x 1.8<br />
8.0 x 1.0<br />
8.0 x 1.2<br />
8.0 x 1.5<br />
9.0 X 0.5<br />
9.0 X 1.0<br />
9.0 X 1.5<br />
9.0 X 1.8<br />
10 X 0.5<br />
10 X 1.0<br />
10 X 1.2<br />
10 X 1.5<br />
12 X 1.0<br />
12 X 1.5<br />
13 X 1.0<br />
13 X 1.5<br />
14 X 1.5<br />
15 X 0.8<br />
15 X 1.0<br />
9.7 x 1.5<br />
6.0 x 1.25<br />
13 x 2.0<br />
4.0 x 0.5<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
52<br />
SHIELDING
SHIELDING<br />
FABRIC OVER FOAM GAS<strong>KE</strong>T<br />
D-PROFILE<br />
53<br />
H<br />
PROFILE NO<br />
<strong>KE</strong>-<strong>FG</strong>-D01<br />
<strong>KE</strong>-<strong>FG</strong>-D02<br />
<strong>KE</strong>-<strong>FG</strong>-D03<br />
<strong>KE</strong>-<strong>FG</strong>-D04<br />
<strong>KE</strong>-<strong>FG</strong>-D05<br />
<strong>KE</strong>-<strong>FG</strong>-D06<br />
<strong>KE</strong>-<strong>FG</strong>-D07<br />
<strong>KE</strong>-<strong>FG</strong>-D08<br />
<strong>KE</strong>-<strong>FG</strong>-D09<br />
<strong>KE</strong>-<strong>FG</strong>-D10<br />
<strong>KE</strong>-<strong>FG</strong>-D11<br />
<strong>KE</strong>-<strong>FG</strong>-D12<br />
<strong>KE</strong>-<strong>FG</strong>-D13<br />
<strong>KE</strong>-<strong>FG</strong>-D14<br />
<strong>KE</strong>-<strong>FG</strong>-D15<br />
<strong>KE</strong>-<strong>FG</strong>-D16<br />
<strong>KE</strong>-<strong>FG</strong>-D17<br />
<strong>KE</strong>-<strong>FG</strong>-D18<br />
<strong>KE</strong>-<strong>FG</strong>-D19<br />
<strong>KE</strong>-<strong>FG</strong>-D20<br />
<strong>KE</strong>-<strong>FG</strong>-D21<br />
<strong>KE</strong>-<strong>FG</strong>-D22<br />
<strong>KE</strong>-<strong>FG</strong>-D23<br />
<strong>KE</strong>-<strong>FG</strong>-D24<br />
<strong>KE</strong>-<strong>FG</strong>-D25<br />
<strong>KE</strong>-<strong>FG</strong>-D26<br />
<strong>KE</strong>-<strong>FG</strong>-D27<br />
<strong>KE</strong>-<strong>FG</strong>-D28<br />
<strong>KE</strong>-<strong>FG</strong>-D29<br />
<strong>KE</strong>-<strong>FG</strong>-D30<br />
<strong>KE</strong>-<strong>FG</strong>-D31<br />
<strong>KE</strong>-<strong>FG</strong>-D32<br />
<strong>KE</strong>-<strong>FG</strong>-D33<br />
<strong>KE</strong>-<strong>FG</strong>-D34<br />
<strong>KE</strong>-<strong>FG</strong>-D35<br />
<strong>KE</strong>-<strong>FG</strong>-D36<br />
<strong>KE</strong>-<strong>FG</strong>-D37<br />
<strong>KE</strong>-<strong>FG</strong>-D38<br />
<strong>KE</strong>-<strong>FG</strong>-D39<br />
<strong>KE</strong>-<strong>FG</strong>-D40<br />
W<br />
SIZE (WxH)<br />
2.3 X 2.3<br />
2.3 X 3.2<br />
3.0 X 2.0<br />
3.0 x 3.0<br />
3.0 x 3.5<br />
3.8 x 1.5<br />
3.8 X 3.0<br />
4.0 X 4.0<br />
5.0 X 2.0<br />
5.0 X 5.0<br />
6.0 X 2.0<br />
6.0 X 4.0<br />
6.0 X 4.5<br />
6.0 X 5.0<br />
6.0 X 5.5<br />
6.0 X 6.0<br />
6.4 X 3.6<br />
6.5 X 3.4<br />
6.5 X 5.0<br />
6.5 X 6.0<br />
7.0 X 5.0<br />
8.0 X 5.0<br />
8.0 X 8.0<br />
8.0 X 10<br />
9.0 X 3.0<br />
9.0 X 3.2<br />
9.0 X 6.0<br />
9.5 X 3.2<br />
9.5 X 6.0<br />
10 X 2.0<br />
10 X 3.0<br />
10 X 4.0<br />
10 X 5.0<br />
10 X 6.0<br />
10 X 7<br />
10 X 10<br />
10 X 12<br />
11 X 4.5<br />
12 X 1<br />
12.7 X 9.5<br />
<strong>KE</strong>-<strong>FG</strong>-D41 13 X 5<br />
<strong>KE</strong> KITAGAWA<br />
PROFILE NO<br />
<strong>KE</strong>-<strong>FG</strong>-D42<br />
<strong>KE</strong>-<strong>FG</strong>-D43<br />
<strong>KE</strong>-<strong>FG</strong>-D44<br />
<strong>KE</strong>-<strong>FG</strong>-D45<br />
<strong>KE</strong>-<strong>FG</strong>-D46<br />
<strong>KE</strong>-<strong>FG</strong>-D110<br />
<strong>KE</strong>-<strong>FG</strong>-D120<br />
<strong>KE</strong>-<strong>FG</strong>-D130<br />
<strong>KE</strong>-<strong>FG</strong>-D140<br />
<strong>KE</strong>-<strong>FG</strong>-D150<br />
C-FOLD PROFILE<br />
SIZE (WxH)<br />
15 X 5.5<br />
15 X 6<br />
18 X 14<br />
18 X 20<br />
18 X 23<br />
9.5 X 6.4<br />
7.6 X 4.8<br />
3.8 X 2.3<br />
17 X 8<br />
4.0 X 2.0<br />
<strong>KE</strong>-<strong>FG</strong>-D160 6.4 X 3.2<br />
<strong>KE</strong>-<strong>FG</strong>-D200 2 X 2<br />
<strong>KE</strong>-<strong>FG</strong>-D210 10 X 2.4<br />
<strong>KE</strong>-<strong>FG</strong>-D230 6 X 7<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
H<br />
W<br />
PROFILE NO SIZE (WxH)<br />
<strong>KE</strong>-<strong>FG</strong>-C01 8.0 x 8.0<br />
<strong>KE</strong>-<strong>FG</strong>-C03 10.7 x 8.5<br />
<strong>KE</strong>-<strong>FG</strong>-C04 10.7 x 9.8<br />
<strong>KE</strong>-<strong>FG</strong>-C10 14.7 x 17.1<br />
<strong>KE</strong>-<strong>FG</strong>-C20 6.35 x 6.35<br />
<strong>KE</strong>-<strong>FG</strong>-C21 5.9 x 6.4<br />
<strong>KE</strong>-<strong>FG</strong>-C23 7.1 x 6.4
SHIELDING<br />
FABRIC OVER FOAM GAS<strong>KE</strong>T<br />
WIDE PROFILE<br />
(I.O. GAS<strong>KE</strong>T)<br />
W<br />
H<br />
P-PROFILE<br />
H<br />
↔<br />
W<br />
PROFILE NO<br />
<strong>KE</strong>-<strong>FG</strong>-W01<br />
<strong>KE</strong>-<strong>FG</strong>-W02<br />
<strong>KE</strong>-<strong>FG</strong>-W03<br />
<strong>KE</strong>-<strong>FG</strong>-W04<br />
<strong>KE</strong>-<strong>FG</strong>-W05<br />
<strong>KE</strong>-<strong>FG</strong>-W06<br />
<strong>KE</strong>-<strong>FG</strong>-W07<br />
<strong>KE</strong>-<strong>FG</strong>-W08<br />
<strong>KE</strong>-<strong>FG</strong>-W09<br />
<strong>KE</strong>-<strong>FG</strong>-W10<br />
<strong>KE</strong>-<strong>FG</strong>-W11<br />
<strong>KE</strong>-<strong>FG</strong>-W12<br />
<strong>KE</strong>-<strong>FG</strong>-W13<br />
<strong>KE</strong>-<strong>FG</strong>-W14<br />
<strong>KE</strong>-<strong>FG</strong>-W15<br />
<strong>KE</strong>-<strong>FG</strong>-W16<br />
<strong>KE</strong>-<strong>FG</strong>-W17<br />
<strong>KE</strong>-<strong>FG</strong>-W18<br />
<strong>KE</strong>-<strong>FG</strong>-W19<br />
<strong>KE</strong>-<strong>FG</strong>-W20<br />
<strong>KE</strong>-<strong>FG</strong>-W21<br />
<strong>KE</strong>-<strong>FG</strong>-W22<br />
<strong>KE</strong>-<strong>FG</strong>-W23<br />
<strong>KE</strong>-<strong>FG</strong>-W24<br />
<strong>KE</strong>-<strong>FG</strong>-W58<br />
<strong>KE</strong>-<strong>FG</strong>-W60<br />
<strong>KE</strong>-<strong>FG</strong>-W77<br />
<strong>KE</strong>-<strong>FG</strong>-W125<br />
<strong>KE</strong>-<strong>FG</strong>-W130<br />
<strong>KE</strong>-<strong>FG</strong>-W140<br />
<strong>KE</strong>-<strong>FG</strong>-W150<br />
<strong>KE</strong>-<strong>FG</strong>-W160<br />
<strong>KE</strong>-<strong>FG</strong>-W170<br />
SIZE (WxH)<br />
18 x 2.0<br />
20 x 2.0<br />
20 x 3.5<br />
21 x 1.0<br />
21 x 2.0<br />
21 x 2.5<br />
21 x 3.7<br />
21 x 4.0<br />
25 x 1.0<br />
25 x 2.0<br />
27 x 2.0<br />
30 x 3.0<br />
31 x 1.0<br />
31 x 2.0<br />
31 x 3.0<br />
32 x 1.0<br />
35 x 2.0<br />
38 x 2.0<br />
40 x 1.0<br />
40 x 2.0<br />
45 x 2.0<br />
55 x 2.5<br />
55 x 3.0<br />
60 x 2.0<br />
<strong>KE</strong>-<strong>FG</strong>-W29 19.1 x 1.0<br />
<strong>KE</strong>-<strong>FG</strong>-W30 21.8 x 1.0<br />
<strong>KE</strong>-<strong>FG</strong>-W38 38.5 X 2.0<br />
<strong>KE</strong>-<strong>FG</strong>-W41 41.0 x 3.5<br />
19.1 x 2.0<br />
21.8 x 2.0<br />
21.7 x 3.7<br />
55 x 1.2<br />
25.4 x 1.0<br />
25.4 x 1.5<br />
18 x 1.0<br />
41.8 x 1.0<br />
43.5 x 2.5<br />
PROFILE NO SIZE (WxH)<br />
<strong>KE</strong>-<strong>FG</strong>-P01 8.0 x 2.0<br />
<strong>KE</strong>-<strong>FG</strong>-P02 8.0 x 4.0<br />
<strong>KE</strong>-<strong>FG</strong>-P03 13.2 x 3.3<br />
<strong>KE</strong>-<strong>FG</strong>-P04 16 x 4.5<br />
↔<br />
H<br />
<strong>KE</strong>-<strong>FG</strong>-P10 13.2 X 4.0<br />
<strong>KE</strong>-<strong>FG</strong>-P91 8.0 X 3.0<br />
KNIFE EDGE PROFILE<br />
W<br />
PROFILE NO SIZE (WxH)<br />
<strong>KE</strong>-<strong>FG</strong>-K01 11.3 x 2.5<br />
<strong>KE</strong>-<strong>FG</strong>-K02 12.7 x 2.5<br />
<strong>KE</strong>-<strong>FG</strong>-K03 19.7 x 6.4<br />
<strong>KE</strong>-<strong>FG</strong>-K04 12.7 x 2.7<br />
(2x adhesive as standard)<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
54<br />
SHIELDING
FOAMGAS<strong>KE</strong>T<br />
KIT<br />
SOFT FOAM ENGINEERING LAB KITS<br />
A selection of our most popular profiles are available in<br />
lab kit with 600mm length.<br />
55<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
CUSTOMISED<br />
GAS<strong>KE</strong>T<br />
Notching, punching, sub-assembly<br />
fabrication and die cutting also available.<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
56<br />
SHIELDING
SHIELDING<br />
PART NUMBER GUIDE<br />
KITAGAWA EMI Shielding Gasket<br />
Profile No.<br />
D = D-Profile<br />
F = Flat Profile<br />
C = C-Fold Profile<br />
R = Rectangular Profile<br />
K = Knife Edge Profile<br />
P = P-Profile<br />
W = Wide Profile<br />
(I.O. Gasket)<br />
Tape of fabric<br />
VNN Standard EMI Gasket with Ripstop Fabric and NiCu<br />
coating, UL94-VO<br />
GLD Gold Gasket with Tatteta Fabric and Au coating<br />
BLK Black Gasket with Ripstop Fabric and Carbon<br />
coating<br />
Tape of Adhesive<br />
T with adhesive<br />
N without adhesive<br />
D with conductive adhesive<br />
KT adhesive with kisscut<br />
finish(half cuton liner)<br />
KD conductive adhesive<br />
with kisscut finish<br />
(half cut on liner)<br />
<strong>KE</strong>-<strong>FG</strong>-<strong>D01VNN0500TSP</strong><br />
KITAGAWA Foam Gasket<br />
Length (in mm)<br />
Suffix SP is added in case of any special option like Die Cut<br />
57<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
SHIELDING<br />
CONDUCTIVE<br />
Features:<br />
FOAM<br />
Kitagawa Conductive Foam provides<br />
excellent X,Y and Z axis conductivity<br />
and offers very good shielding and<br />
grounding effectiveness.<br />
The Foam is designed for low-cycling<br />
applications such as I/O-shielding and<br />
is easy to fix, cut and punch to customers<br />
specification.<br />
Product No:<br />
DECF - 000P<br />
Structure:<br />
P.U coating<br />
Conductive foam<br />
Mesh<br />
Conductive adhesive<br />
Release liner<br />
Characteristics:<br />
Item Standard Reference<br />
Material<br />
P.U. Coating<br />
Conductive foam<br />
Mesh<br />
Adhesive<br />
Release Liner<br />
Conductive adhesive resin composition<br />
Lead (Pb) content<br />
Cadmium (Cd) content<br />
Mercury (Hg) content<br />
Chromium VI (Cr 6+ ) content<br />
Temperature Limit (°C)<br />
Adhesive Strength<br />
(180°peel * gf/ 25mm)<br />
Holding Strength (sec)<br />
Volume conductivity (Ω / sq)<br />
Polymer resin : Polyurethane (conductive)<br />
Polyurethane foam (Copper and Nickel Plated)<br />
Polyester woven mesh with Copper and Nickel plated<br />
Both side conductive adhesive<br />
CP paper (avg 70 μm)<br />
Acrylic ester polyol copolymer + Nickel powder<br />
ISO 6101-2<br />
Not detected<br />
Analytical instrument : AAS<br />
EN 1122<br />
Not detected<br />
Analytical instrument : ICP<br />
ISO 3856/7<br />
Not detected<br />
Analytical instrument : AAS<br />
ISO 3856/5<br />
Not detected<br />
UV-Vis. Spectrophotometer<br />
-10 ~ 60<br />
26°C * 60% R.H.<br />
800<br />
SUS 304Plate 30min, 300mm/min<br />
3.600<br />
PET film (25 μm), 40°C, 500g<br />
0,2<br />
EMQI-1031 ( Inch / 0.5Kgf )<br />
➝<br />
➝<br />
➝<br />
Part list:<br />
Part No<br />
DECF-005P<br />
DECF-008P<br />
DECF-010P<br />
DECF-013P<br />
DECF-015P<br />
DECF-020P<br />
DECF-040P<br />
Thickness (mm)<br />
0.5+/-0.2<br />
0.8+/-0.2<br />
1.0+/-0.2<br />
1.3+/-0.2<br />
1.5+/-0.2<br />
2.0+/-0.3<br />
4.0+/-0.3<br />
<strong>KE</strong> KITAGAWA<br />
Width (mm)<br />
300<br />
300<br />
300<br />
300<br />
300<br />
500<br />
500<br />
Length (m)<br />
50m / roll<br />
50m / roll<br />
50m / roll<br />
50m / roll<br />
50m / roll<br />
50m / roll<br />
50m / roll<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
58<br />
SHIELDING
Ripstop<br />
SHIELDING<br />
SHIELDING<br />
FABRIC<br />
Features:<br />
Conductive fabric is a kind of matarial which conductivity is<br />
endowed by being plated with copper and nickel by non-electrolytic<br />
process on all types of polyester fabrics. This material<br />
is properly applied to the wide range of EMI shielding products<br />
which various designs and sepcitications are required by<br />
engineers because the material has good conductivity and<br />
excellent EMI shielding effectiveness to 30MHz 10GHz frequency<br />
bands. Conductive fabric is easy to shape, light in<br />
weight and the plating materials have good abrasion resistance.<br />
Application:<br />
EMI Gaskets, Conductive Fabric Tapes, ESD,<br />
Cable Shield, shield Case, Shield Sheet, etc.<br />
Shielding Effectivenss(dB)<br />
100<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
0<br />
0 10 20 30 40 50 60 70 80 90 100<br />
Shielding Effectivenss(dB)<br />
100<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
0<br />
0 10 20 30 40 50 60 70 80 90 100<br />
Frequency(MHz)<br />
Frequency(MHz)<br />
<strong>KE</strong>-E2-235C-H<br />
<strong>KE</strong>-E2-235S-H<br />
Shielding Effectivenss(dB)<br />
100<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
0<br />
0 10 20 30 40 50 60 70 80 90 100<br />
Frequency(MHz)<br />
Shielding Effectivenss(dB)<br />
100<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
0<br />
0 10 20 30 40 50 60 70 80 90 100<br />
Frequency(MHz)<br />
<strong>KE</strong>-E1-290C-H<br />
<strong>KE</strong>-E1-290G-H<br />
59<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 3-5 · · D-63110 Rodgau-Jügesheim · FR-Germany · · Telefon · 0 061 61 06/85 24 24 - 0 - 0 · Telefax · 0 061 61 06/85 24-30 (31) (31)
SHIELDING<br />
SHIELDING<br />
FABRIC<br />
Specification of Conductive Fabric<br />
Product No<br />
Type<br />
base<br />
Material<br />
metal<br />
Width<br />
(mm)<br />
Length<br />
(m)<br />
Thickness<br />
(mm)<br />
Max.short<br />
duration<br />
Temp.(°C)<br />
Surface resistance<br />
(Ohm/cm2)<br />
Shielding<br />
Effectiveness<br />
(dB)(30Mhz-1GHz)<br />
<strong>KE</strong>-E1-290C-H<br />
<strong>KE</strong>-E1-290G-H<br />
<strong>KE</strong>-E2-235C-H<br />
<strong>KE</strong>-E2-235S-H<br />
<strong>KE</strong>-E3-50C-H<br />
<strong>KE</strong>-E4-130C-H<br />
Woven<br />
Woven<br />
Ripstop<br />
Ripstop<br />
Non Woven<br />
Mesh<br />
polyester<br />
Cu+Ni<br />
Cu+Ni+Au<br />
Cu+Ni<br />
Cu+Ni+Ag<br />
Cu+Ni<br />
Cu+Ni<br />
1040 50<br />
0.1<br />
0.1<br />
0.09<br />
0.1<br />
0.16<br />
0.07<br />
210<br />
≤0.05<br />
≤0.05<br />
≤0.05<br />
≤0.05<br />
≤0.05<br />
≤0.05<br />
60-70<br />
65-75<br />
60-70<br />
70-80<br />
68-75<br />
60-70<br />
Basic Material Test Result (Conductive Fabric)<br />
Tensile Strength(kgf) Extention (%) Fabric Count (thread/inch) Weight (g/m2)<br />
Warp Weft Warp Weft Warp weft<br />
<strong>KE</strong>-E2-235C-H 49.7 38.3 23.6 27.9 128.8 113.4 73.1<br />
<strong>KE</strong>-E1-290C-H 68.5 40.0 27.6 30.8 184.0 91.0 76.0<br />
<strong>KE</strong>-E2-235S-H 50.2 33.5 28.8 29.6 128.8 113.4 73.1<br />
<strong>KE</strong>-E1-290G-H 60.5 28.8 27.1 27.0 184.0 91.0 76.0<br />
Construction<br />
Theory of EMI shielding<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
60<br />
SHIELDING
SHIELDING<br />
D-SUB<br />
CONNECTOR-GAS<strong>KE</strong>TS<br />
EMI SHIELDING FOR ALL STANDARD<br />
SIZES. Our new I/O Shielding (IOS)<br />
gaskets enhance the performance of<br />
EMI shielding for D-Sub Connectors.<br />
Sized to fit standard D-Subminiature<br />
connectors, IOS gaskets provide multiple<br />
contact points to maintain conductivity,<br />
and compensate for tolerance stackup.<br />
Pressure-sensitive adhesive (PSA) tape<br />
is available, but not usually required<br />
for installation.<br />
With no tooling costs, easy installation,<br />
and off-the-shelf availability, these gaskets<br />
are a simple and efficient solution<br />
to I/O shielding.<br />
D<br />
A<br />
C<br />
E<br />
B<br />
t<br />
Type<br />
9 Pins D09<br />
15 Pins D15<br />
25 Pins D25<br />
37 Pins D37<br />
50 Pins D50<br />
A<br />
33.4<br />
41.7<br />
55.6<br />
71.9<br />
69.6<br />
B<br />
19.1<br />
19.1<br />
19.1<br />
19.1<br />
21.8<br />
C<br />
17.4<br />
25.7<br />
39.6<br />
55.9<br />
53.6<br />
D<br />
10.0<br />
10.0<br />
10.0<br />
10.0<br />
12.0<br />
E<br />
25.4<br />
36.7<br />
47.6<br />
63.9<br />
61.6<br />
t=1mm<br />
W29<br />
W29<br />
W29<br />
W29<br />
W30<br />
t=2mm<br />
W58<br />
W58<br />
W58<br />
W58<br />
W60<br />
Profile Number<br />
W29<br />
W58<br />
W30<br />
W60<br />
Connector Type<br />
D09<br />
D15<br />
D25<br />
D37<br />
D50<br />
With adhesive tape T<br />
Without adhesive N<br />
<strong>KE</strong>-<strong>FG</strong>-W29VNND09T<br />
Foam Gasket<br />
VNN<br />
Standard EMI Gasket with<br />
Ripstop Fabric and NiCu<br />
coating, UL94-VO<br />
61<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 3-5 · · D-63110 Rodgau-Jügesheim · FR-Germany · · Telefon · 0 061 61 06/85 24 24 - 0 - 0 · Telefax · 0 061 61 06/85 24-30 (31) (31)
SHIELDING<br />
CARBON<br />
RUBBER<br />
CARBON RUBBER is a carbon filled<br />
silicone rubber available in the form of<br />
sheet as well as various extruded<br />
shapes as shown here.<br />
CARBON RUBBER is a good shielding<br />
material and an excellent environmental<br />
seal.<br />
Material specifications<br />
Material. conductive silicone (black)<br />
Continuous use temperature range:<br />
-60~200°C<br />
Hardness: 60±5 (JISA) JIS C2123<br />
Tensile Strenght: >50 kg/cm 2 JIS C2123<br />
Tensile elongation: >200% JIS C2123<br />
Volume resistivity: 3~10 Ω cm<br />
Flammability: UL94V-O<br />
„O“ Section<br />
Round Section<br />
Part No.<br />
CSR-O-25-15<br />
CSR-O-60-30<br />
CSR-O-65-30<br />
CSR-O-100-65<br />
„D“ Section<br />
O.D<br />
2.5<br />
6.0<br />
6.5<br />
10.0<br />
I.D<br />
1.5<br />
3.0<br />
3.0<br />
6.5<br />
Part No.<br />
CSR-R-15<br />
CSR-R-20<br />
CSR-R-30<br />
CSR-R-40<br />
CSR-R-60<br />
„P“ Section<br />
D<br />
1.5<br />
2.0<br />
3.0<br />
4.0<br />
6.0<br />
Part No.<br />
CSR-D-40-15<br />
CSR-D-45-25<br />
„U“ Section<br />
A<br />
4.0<br />
4.5<br />
B<br />
1.5<br />
2.5<br />
Part No.<br />
CSR-P-125-50<br />
CSR-P-170-72<br />
CSR-P-240-77<br />
A<br />
12.5<br />
17.0<br />
24.0<br />
B<br />
5.0<br />
7.2<br />
7.7<br />
C<br />
6.0<br />
7.5<br />
11.0<br />
Part No.<br />
CSR-U-48-48<br />
CSR-U-55-110<br />
CSR-U-80-130<br />
CSR-U-95-130<br />
A<br />
4.8<br />
5.5<br />
8.0<br />
9.5<br />
B<br />
4.8<br />
11.0<br />
13.0<br />
13.0<br />
C<br />
3.2<br />
8.0<br />
9.5<br />
9.5<br />
D<br />
1.6<br />
2.5<br />
3.5<br />
5.0<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
62<br />
SHIELDING
SHIELDING<br />
CONDUCTIVE<br />
Features<br />
ELASTOMER<br />
- The Kitagawa Electrically Conductive Elastomers offer excellent shielding<br />
and environmental sealing. They are offered in a range of materials and<br />
outlines to meet various applications.<br />
Dimension + Technical Data<br />
Material:<br />
Conductive particles (nickel) in Silicon<br />
Shore A hardness: 68 +/- 6<br />
Volume resistivity ( Ohm / cm ) 0.1<br />
Temperature range (°C ) -55 to +200<br />
Density ( g/cm 3 ) 3.5<br />
Tensile strength ( % ) 75<br />
Colour<br />
black<br />
Shielding effectiveness ( dB ) H-Field 10 KHz 72<br />
E-Field 1 MHz 115<br />
P-Field 1 GHz 85<br />
Tolerance (mm)<br />
+/- 0.08<br />
+/ - 0.13<br />
+/ - 0.15<br />
+/ - 0.20<br />
+/ - 0.20<br />
Standard Sheets - PL -<br />
Part No.<br />
SG-PL-<br />
SG-PL-<br />
SG-PL-<br />
SG-PL-<br />
SG-PL-<br />
A(mm)<br />
200.00<br />
200.00<br />
200.00<br />
200.00<br />
200.00<br />
B (mm)<br />
-200.00<br />
-200.00<br />
-200.00<br />
-200.00<br />
-200.00<br />
T (mm)<br />
-0.50<br />
-0.80<br />
-1.00<br />
-1.50<br />
-2.00<br />
Custom Gaskets can be cut to customer specification!<br />
Rectangular Strips - R E -<br />
Part No.<br />
SG-RE-<br />
SG-RE-<br />
SG-RE-<br />
SG-RE-<br />
SG-RE-<br />
A (mm)<br />
1.00<br />
1.50<br />
2.00<br />
2.00<br />
2.00<br />
B (mm)<br />
-3.00<br />
-3.00<br />
-2.50<br />
-3.00<br />
-4.00<br />
L (mm)<br />
-1.500.oo<br />
-1.500.00<br />
-1.500.00<br />
-1.500.00<br />
-1.500.00<br />
Tolerance (mm)<br />
A<br />
B<br />
+/ - 0.08 +/ - 0.12<br />
+/ - 0.12 +/ - 0.12<br />
+/ - 0.18 +/ - 0.12<br />
+/ - 0.18 +/ - 0.12<br />
+/ - 0.18 +/ - 0.12<br />
63<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
SHIELDING<br />
CONDUCTIVE<br />
Features<br />
ELASTOMER<br />
- The Kitagawa Conductive Elastomer EMI-Gaskets feature an abrasionresistant,<br />
silver-filled elastomer applied over a non-conductive extruded<br />
silicon core.<br />
Technical data (coating only)<br />
Material:<br />
Ag/Cu particles in Silicon<br />
Volume resistivity ( Ohm / cm ) 0,008<br />
Temperature resistance (°C ) 125<br />
Density ( g/cm 3 ) 3,6<br />
Coating thickness ( mm ) 0,15 +/-0,05<br />
Breaking elongation ( % ) 125<br />
Colour<br />
beige<br />
Shielding effectiveness ( dB ) H-Field 10 kHz 67<br />
E-Field 1 MHz 130<br />
P-Field 1 GHz 110<br />
Elastomer core:<br />
Silicon foam (non conductive)<br />
Density 0,43 g/cm 3<br />
Shore A hardness 30°+/-6<br />
Breaking elongation >90 %<br />
Compression Set < 40 %<br />
Temperature resistance -55/+125° C<br />
Elastomer core:<br />
Silicon tube (non conductive)<br />
Density 1,14 g/cm 3<br />
Shore A hardness 60°+/-6<br />
Breaking elongation >45 %<br />
Compression Set < 35 %<br />
Temperature resistance -55/+125° C<br />
Elastomer core:<br />
Silicon solid round (non conductive)<br />
Density 1,08 g/cm 3<br />
Shore A hardness 60° +/- 7<br />
Breaking elongation >180 %<br />
Compression Set < 35%<br />
Temperature resistance -55/+125° C<br />
Part No. D A (mm) Tolerance (mm)<br />
SG-FO-1.50 +/- 0.18<br />
SG-FO-1.80 +/- 0.20 3<br />
SG-FO-2.00 +/- 0.20<br />
SG-FO-2.30 +/- 0.20<br />
SG-FO-2.50 +/- 0.25<br />
SG-FO-2.80 +/- 0.25<br />
SG-FO-3.00 +/- 0.25<br />
SG-FO-3.30 +/- 0.25<br />
SG-FO-3,80 +/- 0.30<br />
SG-FO-4.00 +/- 0.30<br />
SG-FO-4.30 +/- 0.30<br />
SG-FO-4.50 +/- 0.30<br />
SG-FO-4.80 +/- 0.35<br />
SG-FO-5.o0 +/- 0.35<br />
SG-FO-5.30 +/- 0.35<br />
SG-FO-5.50 +/- 0.35<br />
SG-FO-6.00 +/- 0.35<br />
Max. available outer diameter 7.50 mm<br />
Part No. D A D I (mm) Tolerance (mm)<br />
SG-TU- 1.30 -0.50 +/- 0.15<br />
SG-TU- 1.50 -0.50 +/- 0.15 3<br />
SG-TU- 1.60 -0.50 +/- 0.20<br />
SG-TU- 1.80 -1.00 +/- 0.20<br />
SG-TU- 2.00 -1.00 +/- 0.20<br />
SG-TU- 2.10 -1.00 +/- 0.20<br />
SG-TU- 2.30 -1.00 +/- 0.20<br />
SG-TU- 2.60 -1.00 +/- 0.25<br />
SG-TU- 3.00 -1.00 +/- 0.25<br />
SG-TU- 3.00 -1.50 +/- 0.25<br />
SG-TU- 3.30 -1.50 +/- 0.25<br />
SG-TU- 3.60 -1.50 +/- 0.25<br />
SG-TU- 4.10 -1.50 +/- 0.25<br />
SG-TU- 4.80 -2.00 +/- 0.30<br />
SG-TU- 5.30 -2.00 +/- 0.30<br />
SG-TU- 5.80 -2.00 +/- 0.35<br />
<strong>KE</strong> KITAGAWA<br />
Part No. D A (mm) Tolerance (mm)<br />
SG-RO-1.20 +/- 0.15<br />
SG-RO-1.50 +/- 0.15 3<br />
SG-RO-1.80 +/- 0.15<br />
SG-RO-2.00 +/- 0.15<br />
SG-RO-2.30 +/- 0.20<br />
SG-RO-2.50 +/- 0.20<br />
SG-RO-2.80 +/- 0.25<br />
SG-RO-3.00 +/- 0.25<br />
SG-RO-3.30 +/- 0.25<br />
SG-RO-3.50 +/- 0.25<br />
SG-RO-3.80 +/- 0.25<br />
SG-RO-4.00 +/- 0.30<br />
SG-RO-4.30 +/- 0.30<br />
SG-RO-4.50 +/- 0.30<br />
SG-RO-4.80 +/- 0.30<br />
SG-RO-5.50 +/- 0.35<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
64<br />
SHIELDING
SHIELDING<br />
ALL METAL GAS<strong>KE</strong>TS<br />
Features<br />
- Simplest method of maintaining electrical continuty between two<br />
mating surface<br />
- Highest attenuation level (according to MIL-285) during operative life<br />
- No temperature limits<br />
- Fabricated and cut-to-length gaskets<br />
- Pressure sensitive adhesive (as an option)<br />
Material<br />
- Monel (MO)<br />
- Tinned copper clad steel (TC)<br />
- Stainless steel (SL)<br />
Tolerances<br />
1,5-5 mm +0,4 - 0 mm<br />
6-10 mm +0,6 - 10 mm<br />
> 10 mm +0,8 - 0 mm<br />
- Berillium copper (BC)*<br />
- Tinned copper (TR)*<br />
- Phosphor bronze (PB)*<br />
- Aluminium (AL)*<br />
*upon request<br />
Ordering information: Complete the P/N with the 2-letter Metall Suffix i.e. MG-R.032.064.MO or MG-B.080.254.SL<br />
Round Rectangular P section Double P section<br />
P/N<br />
Diameter<br />
(mm)<br />
P/N Height Width<br />
(mm) (mm)<br />
P/N<br />
Diameter Width<br />
(mm) (mm)<br />
P/N<br />
Diameter Width<br />
(mm) (mm)<br />
MG-T.016<br />
MG-T.024<br />
MG-T.032<br />
MG-T.048<br />
MG-T.064<br />
MG-T.080<br />
MG-T.095<br />
MG-T.111<br />
MG-T.127<br />
MG-T.159<br />
MG-T.191<br />
1.6<br />
2.4<br />
3.2<br />
4.8<br />
6.4<br />
8.0<br />
9.5<br />
11.1<br />
12.7<br />
15.9<br />
19.1<br />
MG-R.024.024<br />
MG-R.024.048<br />
MG-R.024.064<br />
MG-R.032.032<br />
MG-R.032.064<br />
MG-R.032.080<br />
MG-R.048.048<br />
MG-R.048.080<br />
MG-R.048.127<br />
MG-R.064.064<br />
MG-R.064.127<br />
MG-R.080.127<br />
MG-R.095.127<br />
2.4<br />
2.4<br />
2.4<br />
3.2<br />
3.2<br />
3.2<br />
4.8<br />
4.8<br />
4.8<br />
6.4<br />
6.4<br />
8.0<br />
9,5<br />
2.4<br />
4.8<br />
6.4<br />
3.2<br />
6.4<br />
8.0<br />
4.8<br />
8.0<br />
12.7<br />
6.4<br />
12.7<br />
12.7<br />
12.7<br />
MG-P.032.095<br />
MG-P.032.127<br />
MG-P.032.159<br />
MG-P.032.191<br />
MG-P.048.127<br />
MG-P.048.159<br />
MG-P.048.191<br />
MG-P.048.222<br />
MG-P.080.159<br />
MG-P.080.191<br />
MG-P.080.222<br />
MG-P.080.254<br />
MG-P.095.320<br />
3.2<br />
3.2<br />
3.2<br />
3.2<br />
4.8<br />
4.8<br />
4.8<br />
4.8<br />
8.0<br />
8.0<br />
8.0<br />
8.0<br />
9.5<br />
9.5<br />
12.7<br />
15.9<br />
19.1<br />
12.7<br />
15.9<br />
19.1<br />
22.2<br />
15.9<br />
19.1<br />
22.2<br />
25.4<br />
32.0<br />
MG-B.032.095<br />
MG-B.032.127<br />
MG-B.032.159<br />
MG-B.032.191<br />
MG-B.048.159<br />
MG-B.048.191<br />
MG-B.048.222<br />
MG-B.048.254<br />
MG-B.080.191<br />
MG-B.080.222<br />
MG-B.080.254<br />
MG-B.080.320<br />
MG-B.095.320<br />
3.2<br />
3.2<br />
3.2<br />
3.2<br />
4.8<br />
4.8<br />
4.8<br />
4.8<br />
8.0<br />
8.0<br />
8.0<br />
8.0<br />
9.5<br />
9.5<br />
12.7<br />
15.9<br />
19.1<br />
15.9<br />
19.1<br />
22.2<br />
25.4<br />
19.1<br />
22.2<br />
25.4<br />
32.0<br />
32.0<br />
Other sizes, configurations or ready-to-mount finished gaskets (according to your drawing)<br />
available upon request<br />
65<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
SHIELDING<br />
WIRE MESH OVER ELASTOMER CORE GAS<strong>KE</strong>TS<br />
Features<br />
- Improved resiliency combined with dust and moisture sealing.<br />
- Excellent attenuation characteristics (95-100dB in E-field,<br />
45-90dB in H-field).<br />
- Fabricated and cut-to-length gaskets.<br />
- Pressure sensitive adhesive (as an option).<br />
Material<br />
Wide range of core:<br />
- Neoprene sponge (-40 °C to + 85 °C) (NS)<br />
- EPDM sponge (-40 °C to + 100 °C) (ES)<br />
- Silicone sponge (-50 °C to + 200 °C) (SS)<br />
- Silicone tubing (-50 °C to + 200 °C) (ST)<br />
- Low density foam (-30 °C to + 80 °C) (LF)*<br />
and wire materials:<br />
- Monel (MO)<br />
- Tinned copper clad steel (TC)<br />
- Stainless steel (SL)<br />
Tolerances<br />
1.5-5 mm +/- 0.3 mm<br />
6-12 mm +/- 0.6 mm<br />
> 12 mm +/- 0.9 mm<br />
- Berillium copper (BC)*<br />
- Tinned copper (TR)*<br />
- Phosphor bronze (PB)*<br />
- Aluminium (AL)*<br />
*upon request<br />
Ordering information:<br />
Complete the P/N with i.e. MG-BE.048.159.ST.2-MO<br />
- the 2- letter core suffix Double P section, 3.2 x 15,9 mm, 2 layers of monel wire over silicon tube<br />
- the number of layers (2 is standard) i.e. MG-RE.064.064.NS.3-TC<br />
- the 2-letter metal suffix Square section, 6.4 x 6.4 mm, 3 layers of tin copper clad steel wire on<br />
neoprene sponge<br />
Round Rectangular P section Double P section<br />
P/N<br />
Diameter<br />
(mm)<br />
P/N Height Width<br />
(mm) (mm)<br />
P/N<br />
Diameter Width<br />
(mm) (mm)<br />
P/N<br />
Diameter Width<br />
(mm) (mm)<br />
MG-TE.016<br />
MG-TE.024<br />
MG-TE.032<br />
MG-TE.050<br />
MG-TE.064<br />
MG-TE.080<br />
MG-TE.095<br />
MG-TE.111<br />
MG-TE.127<br />
MG-TE.159<br />
MG-TE.191<br />
1.6<br />
2.4<br />
3.2<br />
5.0<br />
6.4<br />
8.0<br />
9.5<br />
11.1<br />
12.7<br />
15.9<br />
19.1<br />
MG-RE.024.024<br />
MG-RE.024.048<br />
MG-RE.024.064<br />
MG-RE.032.032<br />
MG-RE.032.064<br />
MG-RE.032.080<br />
MG-RE.048.048<br />
MG-RE.048.080<br />
MG-RE.048.127<br />
MG-RE.064.064<br />
MG-RE.064.127<br />
MG-RE.080.127<br />
MG-RE.095.127<br />
2.4<br />
2.4<br />
2.4<br />
3.2<br />
3.2<br />
3.2<br />
4.8<br />
4.8<br />
4.8<br />
6.4<br />
6.4<br />
8.0<br />
9.5<br />
2.4<br />
4.8<br />
6.4<br />
3.2<br />
6.4<br />
8.0<br />
4.8<br />
8.0<br />
12.7<br />
6.4<br />
12.7<br />
12.7<br />
12.7<br />
MG-PE.032.095<br />
MG-PE.032.127<br />
MG-PE.032.159<br />
MG-PE.032.191<br />
MG-PE.048.127<br />
MG-PE.048.159<br />
MG-PE.048.191<br />
MG-PE.048.222<br />
MG-PE.080.159<br />
MG-PE.080.191<br />
MG-PE.080.222<br />
MG-PE.080.254<br />
MG-PE.095.320<br />
3.2<br />
3.2<br />
3.2<br />
3.2<br />
4.8<br />
4.8<br />
4.8<br />
4.8<br />
8.0<br />
8.0<br />
8.0<br />
8.0<br />
9.5<br />
9.5<br />
12.7<br />
15.9<br />
19.1<br />
12.7<br />
15.9<br />
19.1<br />
22.2<br />
15.9<br />
19.1<br />
22.2<br />
25.4<br />
32.0<br />
MG-BE.032.095<br />
MG-BE.032.127<br />
MG-BE.032.159<br />
MG-BE.032.191<br />
MG-BE.048.159<br />
MG-BE.048.191<br />
MG-BE.048.222<br />
MG-BE.048.254<br />
MG-BE.080.191<br />
MG-BE.080.222<br />
MG-BE.080.254<br />
MG-BE.080.320<br />
MG-BE.095.320<br />
3.2<br />
3.2<br />
3.2<br />
3.2<br />
4.8<br />
4.8<br />
4.8<br />
4.8<br />
8.0<br />
8.0<br />
8.0<br />
8.0<br />
9.5<br />
9.5<br />
12.7<br />
15.9<br />
19.1<br />
15.9<br />
19.1<br />
22.2<br />
25.4<br />
19.1<br />
22.2<br />
25.4<br />
32.0<br />
32.0<br />
Other sizes, configurations or ready-to-mount finished gaskets (according to your drawing)<br />
available upon request<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
66<br />
SHIELDING
SHIELDING<br />
MULTISTRIP<br />
GAS<strong>KE</strong>TS<br />
Features<br />
- Combination of knitted wire mesh bonded to an elastomer which<br />
provides an EMI shield as well as an environmental sealing<br />
- Complete choice of knitted wire materials<br />
- Pressure sensitive adhesive on elastomer for easy application<br />
- Customized and cut-to-length gaskets<br />
Material<br />
Range of elastomer strips:<br />
- Neoprene sponge (-40 °C to + 85 °C) (NS)<br />
- EPDM sponge (-40 °C to + 100 °C) (ES)<br />
and wire materials:<br />
- Monel (MO)<br />
- Tinned copper clad steel (TC)<br />
- Stainless steel (SL)<br />
- Berillium copper (BC)*<br />
- Tinned copper (TR)*<br />
- Phosphor bronze (PB)*<br />
- Aluminium (AL)*<br />
*upon request<br />
Tolerances<br />
Elastomer<br />
2-3 mm ±0,4 mm<br />
4-12 mm ±0,8 mm<br />
Knitted mesh<br />
2-5 mm +0,4 - 0 mm<br />
6-10 mm +0,5 - 0,3 mm<br />
>10 mm +1,2 - 0,5 mm<br />
Ordering information:<br />
Complete the P/N with i.e. MG-REM.032.032.159.SS.TR<br />
- the 2-letter elastomer suffix Single 3.2 x 3.2 mm tinned copper mesh combined to 3.2 x 15.9 mm<br />
silicone sponge.<br />
- the 2-letter metal suffix i.e. MG-REDM.032.064.095.NS.MO<br />
Double 3.2 x 6.4 mm monel mesh combined to 3.2 x 9.5 mm neoprene sponge<br />
Single<br />
Double<br />
P/N Mesh Elastomer<br />
Height Width Width<br />
(mm) (mm) (mm)<br />
MG-REM.024.032.095<br />
MG-REM.032.032.127<br />
MG-REM.032.032.159<br />
MG-REM.032.064.127<br />
MG-REM.048.048.127<br />
MG-REM.048.064.159<br />
MG-REM.048.064.191<br />
MG-REM.048.095.127<br />
MG-REM.064.064.159<br />
MG-REM.064.095.191<br />
MG-REM.095.064.127<br />
MG-REM.095.064.191<br />
2.4<br />
3.2<br />
3.2<br />
3.2<br />
4.8<br />
4.8<br />
4.8<br />
4.8<br />
6.4<br />
6.4<br />
9.5<br />
9.5<br />
3.2<br />
3.2<br />
3.2<br />
6.4<br />
4.8<br />
6.4<br />
6.4<br />
9.5<br />
6.4<br />
9.5<br />
6.4<br />
6.4<br />
9.5<br />
12.7<br />
15.9<br />
12.7<br />
12.7<br />
15.9<br />
19.1<br />
12.7<br />
15.9<br />
19.1<br />
12.7<br />
19.1<br />
P/N Mesh Elastomer<br />
Height Width Width<br />
(mm) (mm) (mm)<br />
MG-REDM.032.032.064<br />
MG-REDM.032.032.095<br />
MG-REDM.032.032.127<br />
MG-REDM.032.064.095<br />
MG-REDM.032.064.127<br />
MG-REDM.048.032.064<br />
MG-REDM.048.032.127<br />
MG-REDM.048.064.127<br />
3.2<br />
3.2<br />
3.2<br />
3.2<br />
3.2<br />
4.8<br />
4.8<br />
4.8<br />
3.2<br />
3.2<br />
3.2<br />
6.4<br />
6.4<br />
3.2<br />
3.2<br />
6.4<br />
6.4<br />
9.5<br />
12.7<br />
9.5<br />
12.7<br />
6.4<br />
12.7<br />
12.7<br />
Other sizes, configurations or ready-to-mount finished gaskets (according to your drawing)<br />
available upon request<br />
67<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
SHIELDING<br />
SYNTHETIC YARN KNITTED GAS<strong>KE</strong>TS<br />
Features<br />
- Silver plated synthetic yarn knitted over elastomer<br />
- Optimal electric conductivity of every single fiber<br />
- High coverage knitted yarn for wide contact surface and shielding<br />
- Smooth and soft surface gasket<br />
- Self- terminating cut ends<br />
- Pressure sensitive adhesive<br />
- Customized and cut-to-length gaskets<br />
- Shielding efficiency as high as 100 dB in a frequency range of<br />
1 MHz to 1 GHz (E-field)<br />
- Standard core material: neoprene sponge<br />
Other core materials available upon request<br />
Tolerances<br />
- ± 0,75 mm<br />
Round Rectangular D section<br />
P/N<br />
Diameter<br />
(mm)<br />
P/N Height Width<br />
(mm) (mm)<br />
P/N Height Width<br />
(mm) (mm)<br />
MG-YTE.016<br />
MG-YTE.024<br />
MG-YTE.032<br />
MG-YTE.048<br />
MG-YTE.064<br />
MG-YTE.080<br />
MG-YTE.095<br />
MG-YTE.111<br />
MG-YTE.127<br />
MG-YTE.159<br />
MG-YTE.191<br />
1.6<br />
2.4<br />
3.2<br />
4.8<br />
6.4<br />
8.0<br />
9.5<br />
11.1<br />
12.7<br />
15.9<br />
19.1<br />
MG-YRE.024.024<br />
MG-YRE.024.048<br />
MG-YRE.024.064<br />
MG-YRE.032.032<br />
MG-YRE.032.064<br />
MG-YRE.032.080<br />
MG-YRE.048.048<br />
MG-YRE.048.080<br />
MG-YRE.048.127<br />
MG-YRE.064.064<br />
MG-YRE.064.127<br />
MG-YRE.080.127<br />
MG-YRE.095.127<br />
2.4<br />
2.4<br />
2.4<br />
3.2<br />
3.2<br />
3.2<br />
4.8<br />
4.8<br />
4.8<br />
6.4<br />
6.4<br />
8.0<br />
9.5<br />
2.4<br />
4.8<br />
6.4<br />
3.2<br />
6.4<br />
8.0<br />
4.8<br />
8.0<br />
12.7<br />
6.4<br />
12.7<br />
12.7<br />
12.7<br />
MG-YDE.048.064<br />
MG-YDE.064.095<br />
MG-YDE.064.127<br />
MG-YDE.095.127<br />
4.8<br />
6.4<br />
6.4<br />
9.5<br />
6.4<br />
9.5<br />
12.7<br />
12.7<br />
Other sizes, configurations or ready-to-mount finished gaskets (according to your drawing)<br />
available upon request<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
68<br />
SHIELDING
SHIELDING<br />
SPRING SERIES GAS<strong>KE</strong>TS<br />
Features<br />
- Minimum compression force and high resiliency gaskets<br />
- Optimum attenuating properties :<br />
copper beryllium, E-field<br />
tin copper clad steel, H-field<br />
(combination of 2 materials is possible)<br />
- 100% free height recovery after deflection during operative life<br />
- No moisture absorption<br />
- Fabricated and cut-to-length gaskets<br />
- Pressure sensitive adhesive (on „D“ shape gaskets)<br />
Material<br />
- Beryllium Copper (BC)<br />
- Stainless steel (SL)*<br />
- Tinned Copper Clad Steel (TC)*<br />
(only in combination with BC or SL)<br />
*upon request<br />
Tolerances<br />
1,5-5 mm +0,4 - 0 mm<br />
6-10 mm +0,6 - 10 mm<br />
> 10 mm +0,8 - 0 mm<br />
Ordering information:<br />
Complete the P/N with i.e. MG-SB.032.127.1-SL<br />
- the number of wires Double P section, 3.2 x 12.7 mm, 1 stainless steel wire<br />
- the 2-letter metal suffix MG-SD.080.095.2-BC<br />
D section, 8.0 x 9.5 mm, 2 beryllium copper wires<br />
Round P section Double P section D section<br />
P/N<br />
Diameter<br />
(mm)<br />
P/N<br />
Diameter Width<br />
(mm) (mm)<br />
P/N<br />
Diameter Width<br />
(mm) (mm)<br />
P/N<br />
Height Width<br />
(mm) (mm)<br />
MG-ST.016<br />
MG-ST.024<br />
MG-ST.032<br />
MG-ST.048<br />
MG-ST.064<br />
MG-ST.080<br />
MG-ST.095<br />
MG-ST.111<br />
MG-ST.127<br />
1.6<br />
2.4<br />
3.2<br />
4.8<br />
6.4<br />
8.0<br />
9.5<br />
11.1<br />
12.7<br />
MG-SP.016.095<br />
MG-SP.024.127<br />
MG-SP.032.127<br />
MG-SP.032.159<br />
MG-SP.048.159<br />
MG-SP.064.191<br />
MG-SP.064.254<br />
MG-SP.080.254<br />
MG-SP.095.320<br />
1.6<br />
2.4<br />
3.2<br />
3.2<br />
4.8<br />
6.4<br />
6.4<br />
8.0<br />
9.5<br />
9.5<br />
12.7<br />
12.7<br />
15.9<br />
15.9<br />
19.1<br />
25.4<br />
25.4<br />
32.0<br />
MG-SB.024.127<br />
MG-SB.032.127<br />
MG-SB.032.159<br />
MG-SB.048.159<br />
MG-SB.048.191<br />
MG-SB.064.191<br />
MG-SB.064.254<br />
MG-SB.080.254<br />
MG-SB.090.320<br />
2.4<br />
3.2<br />
3.2<br />
4.8<br />
4.8<br />
6.4<br />
6.4<br />
8.0<br />
9.5<br />
12.7<br />
12.7<br />
15.9<br />
15.9<br />
19.1<br />
19.1<br />
25.4<br />
25.4<br />
32.0<br />
MG-SD.032.051<br />
MG-SD.048.064<br />
MG-SD.064.080<br />
MG-SD.080.095<br />
MG-SD.095.127<br />
3.2<br />
4.8<br />
6.4<br />
8.0<br />
9.5<br />
5.1<br />
6.4<br />
8.0<br />
9.5<br />
12.7<br />
Other sizes, configurations or ready-to-mount finished gaskets (according to your drawing)<br />
available upon request<br />
69<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
SHIELDING<br />
MESH TAPES<br />
Features<br />
- Especially designed for shielding and grounding of electrical and<br />
electronic cable assemblies<br />
- Flexible structure to conform to irregular surfaces and contours<br />
during the wrapping process (50% overlap bandage)<br />
- Tin plating to allow solderability<br />
- Useful for static discharge (ESD)<br />
- Tin copper clad steel is standard material (best performance),<br />
several other alloys and wire diameters available<br />
Material<br />
- Tinned copper clad steel (TC)<br />
- Tinned copper (TR)<br />
- Stainless steel (SL)<br />
- Monel (MO)<br />
- Brass (BR)<br />
Tolerances<br />
up to 20mm +/-0.8mm<br />
21 - 50mm +/-1.3mm<br />
51 - 155mm +/-2.0mm<br />
Ordering information:<br />
Complete the P/N with the 2-letter metal suffix i.e. MG-C.0127.TC<br />
Tape 12.7 mm width, tin copper clad steel wire<br />
MG-C.0501.BR<br />
Tape 50.1 mm width, brass wire<br />
P/N<br />
Width<br />
(mm)<br />
MG-C.0127<br />
12.7<br />
MG-C.0191<br />
MG-C.0254<br />
MG-C.0508<br />
MG-C.0762<br />
MG-C.1016<br />
19.1<br />
25.4<br />
50.8<br />
76.2<br />
101.6<br />
Frequency<br />
1 MHz<br />
10 MHz<br />
100 MHz<br />
1 GHz<br />
TC<br />
78<br />
66<br />
60<br />
55<br />
MO<br />
70<br />
64<br />
60<br />
56<br />
Attenuation [dB]<br />
SL<br />
69<br />
61<br />
58<br />
51<br />
Al<br />
73<br />
63<br />
58<br />
56<br />
TR<br />
73<br />
65<br />
59<br />
54<br />
MG-C.1524<br />
152.4<br />
10 GHz<br />
40<br />
42<br />
37<br />
44<br />
40<br />
supplied in 50m rolls<br />
Note: These values are indicative only and are for 50% overlap, giving effective 4 layers of mesh for shielding<br />
OEM CUSTOMER MADE PRODUCTS<br />
Wire mesh & elastomer composites<br />
Layers of knitted wire forming sections of varying<br />
construction with or without an elastomer core.<br />
They can be supplied, to suit the application,<br />
with any of the above variants fitted to a seperate<br />
elastomer carrier or incorporated in an aluminium<br />
carrier.<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
70<br />
SHIELDING
SHIELDING<br />
COPPER BERYLLIUM FINGER STRIPS<br />
Features<br />
Copper beryllium owes its wide range of application to the unique performance<br />
qualities it has:<br />
- extraordinary elasticity<br />
- strength<br />
- fatigue strength<br />
- high conductivity<br />
- resistance against environmental influences such as ozone, epipolar<br />
rays and light, also against solvents and corrosion.<br />
- Furthermore, copper beryllium can be used under a wide temperature range<br />
and is not burnable or flammable. It does not evolve gas either. If handled<br />
correctly, it acts self purificating, for example when it is employed as a door<br />
shield for opening and closing.<br />
Technical Data<br />
Specific gravity: 8,4 g/cm 3<br />
Fusing point: 900 °C<br />
Coefficient of expansion (20-200 °C) 17 10 -6 /°C<br />
Thermal conductivity: 0.27 cal/cm s °C; 1.13 W/cm °C<br />
Diamond pyramid hardness: 350-430 kp/mm 2<br />
Tensile strength: 1200-1450 N/mm 2<br />
Fatigue strength, load application 10 8 : 250-290 N/mm 2<br />
Modulus of elasticity: 135000 N/mm 2<br />
Torsion modulus: 47000 N/mm 2<br />
Spring bending limit: 820-950 N/mm 2<br />
Electric conductivity: 12.5-13 m/Ωmm 2<br />
Technical data can be subject to alteration<br />
Plating finishes:<br />
-01 Bright finish<br />
-02 Tin plated<br />
-03 Silver plated<br />
-04 Nickel plated<br />
-05 Gold plated<br />
Ordering information: Part No. Finish-ID. length (mm)<br />
CB- xxxx - xx - xxxxx<br />
CB-0002<br />
A<br />
mm<br />
B<br />
mm<br />
A<br />
CB-0002 5.84 3.56<br />
B<br />
copper beryllium 0.08 mm/ 500 mm, endless, with adhesive tape<br />
71<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
SHIELDING<br />
COPPER BERYLLIUM FINGER STRIPS<br />
CB-0003<br />
CB-0004<br />
A<br />
B<br />
A<br />
mm<br />
B<br />
mm<br />
CB-0003 7.60 3.53<br />
CB-0004 8.64 4.57<br />
copper beryllium 0.08 mm/ 500 mm, endless, with adhesive tape<br />
CB-0005<br />
CB-0006<br />
CB-0007<br />
(-0006) (-0007)<br />
copper beryllium 0.08 mm/ 500 mm, endless, with adhesive tape<br />
copper beryllium 0.08 mm/ 500 mm, with adhesive tape<br />
CB-0008<br />
CB-0009<br />
CB-0010<br />
(-0008) (-0009)<br />
copper beryllium 0.08 mm/ 500 mm, with adhesive tape<br />
copper beryllium 0.07 mm/ 500 mm, endless, with adhesive tape<br />
xx<br />
CB-0011<br />
CB-0012<br />
xx<br />
copper beryllium 0.08 mm/ 406 mm, endless, with adhesive tape<br />
copper beryllium 0.09mm/ 609,6 mm and 7620 mm, with adhesive tape<br />
CB-0013<br />
- CB-0015<br />
B<br />
E<br />
F<br />
CB-0013<br />
A<br />
8.1<br />
B<br />
2.8<br />
C<br />
5.3<br />
D<br />
0.05<br />
E<br />
4.3<br />
F<br />
0.5<br />
L<br />
406<br />
mm<br />
A<br />
C<br />
CB-0014<br />
9.4<br />
3.3<br />
5.3<br />
0.05<br />
5.7<br />
0.6<br />
406<br />
mm<br />
L<br />
D<br />
CB-0015 15.2 5.6 7.1 0.08 8.7 0.8 406<br />
with adhesive tape<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
mm<br />
72<br />
SHIELDING
SHIELDING<br />
COPPER BERYLLIUM FINGER STRIPS<br />
CB-0016 - CB-0021<br />
0.4<br />
2<br />
A<br />
0.8<br />
C<br />
0.076<br />
CB-0016<br />
CB-0017<br />
CB-0018<br />
CB-0019<br />
A<br />
3.8<br />
3.8<br />
4.1<br />
4.1<br />
B<br />
1.0<br />
1.5<br />
1.0<br />
1.5<br />
C<br />
3.0<br />
2.5<br />
4.0<br />
3.5<br />
L<br />
406<br />
406<br />
406<br />
406<br />
mm<br />
mm<br />
mm<br />
mm<br />
B<br />
CB-0020<br />
CB-0021<br />
5.8<br />
5.8<br />
1.0<br />
1.5<br />
4.0<br />
3.5<br />
406<br />
406<br />
mm<br />
mm<br />
CB-0022 - CB-0027<br />
0,4<br />
3.8<br />
1.78<br />
0.076<br />
CB-0022<br />
CB-0023<br />
A<br />
4.8<br />
4.8<br />
B<br />
1.0<br />
1.5<br />
C<br />
3.3<br />
3.0<br />
L<br />
406<br />
406<br />
mm<br />
mm<br />
CB-0024<br />
4.8<br />
2.0<br />
2.8<br />
406<br />
mm<br />
A<br />
C<br />
CB-0025<br />
6.4<br />
1.0<br />
5.1<br />
406<br />
mm<br />
CB-0026<br />
6.4<br />
1.5<br />
4.6<br />
406<br />
mm<br />
B<br />
CB-0027<br />
6.4<br />
2.0<br />
4.1<br />
406<br />
mm<br />
CB-0034<br />
B<br />
CB-0034<br />
Oblong hole<br />
no<br />
copper beryllium 0.13 mm/ 406 mm and 500 mm<br />
CB-0036<br />
CB-0037<br />
xx<br />
copper beryllium 0.13 mm/ 500 mm, endless<br />
copper beryllium 0.09 mm/ 59 mm<br />
CB-0038 - CB-0039<br />
A<br />
B<br />
A<br />
mm<br />
B<br />
mm<br />
CB-0038 3.2 1.5<br />
CB-0039 8.0 1.5<br />
500<br />
73<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
SHIELDING<br />
COPPER BERYLLIUM FINGER STRIPS<br />
CB-0042<br />
CB-0044<br />
copper beryllium 0.13 mm/ 500 mm<br />
copper beryllium 0.13 mm/ 500 mm, with T-lance<br />
CB-0045<br />
CB-0046<br />
copper beryllium 0.13 mm/ 500 mm and coil, 10m<br />
copper beryllium 0.13 mm/ 500 mm and coil, 10 m, with oblong hole<br />
CB-0048<br />
CB-0049<br />
B<br />
A<br />
A<br />
mm<br />
B<br />
mm<br />
CB-0048 9.1 7.7<br />
CB-0049 11.5 9.8<br />
copper beryllium 0.2 mm/ 500 mm<br />
CB-0050<br />
CB-0051<br />
C<br />
A B C<br />
mm mm mm<br />
B<br />
A<br />
CB-0050 9.5 6.4 7.0<br />
CB-0051 12.0 8.4 8.0<br />
copper beryllium 0.2 mm/ 500 mm<br />
CB-0057<br />
copper beryllium 0.2 mm/ 500 mm<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
74<br />
SHIELDING
SHIELDING<br />
COPPER BERYLLIUM FINGER STRIPS<br />
CB-0059<br />
A<br />
mm<br />
CB-0059 18.5<br />
copper beryllium 0.2 mm/ 500 mm<br />
CB-0060<br />
CB-0061<br />
A<br />
mm<br />
A<br />
CB-0060 13.8<br />
CB-0061 18.3<br />
copper beryllium 0.2 mm/ 500 mm<br />
CB-0062<br />
CB-0063<br />
A<br />
mm<br />
CB-0062 11.0<br />
A<br />
CB-0063 15.0<br />
copper beryllium 0.13 mm/ 500 mm<br />
CB-0064<br />
CB-0065<br />
A<br />
A<br />
mm<br />
A<br />
CB-0064 11.0<br />
CB-0065 15.0<br />
copper beryllium 0.2 mm/ 500 mm<br />
75<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 3-5 · · D-63110 Rodgau-Jügesheim · FR-Germany · · Telefon · 0 061 61 06/85 24 24 - 0 - 0 · Telefax · 0 061 61 06/85 24-30 (31) (31)
SHIELDING<br />
COPPER BERYLLIUM FINGER STRIPS<br />
CB-0121<br />
23.72<br />
2.03<br />
0.38<br />
50° ø2<br />
4.06<br />
1.18 1.30<br />
19.05<br />
copper beryllium 0.08 mm/ 300 mm<br />
300<br />
CB-0122<br />
CB-0123<br />
1.02<br />
8.51<br />
6.40<br />
3.66<br />
3.09<br />
19.80<br />
406<br />
R9.00<br />
R1.80<br />
6.40<br />
0.08<br />
8.3<br />
2.91<br />
R8.01(IND)<br />
R0.31(INT)<br />
3.18<br />
406<br />
0.64<br />
15.21<br />
copper beryllium 0.13 mm/ 406 mm<br />
copper beryllium 0.08 mm/ 406 mm<br />
CB-0124<br />
CB-0125 - CB-0132<br />
copper beryllium 0.08 mm/ 228.96 mm<br />
CB-0125<br />
A<br />
8.13<br />
B<br />
2.79<br />
C<br />
2.16<br />
D<br />
0.08<br />
E<br />
4.29<br />
F<br />
0.46<br />
R<br />
2.79<br />
L<br />
408<br />
CB-0126<br />
7.87<br />
3.05<br />
2.28<br />
0.08<br />
5.85<br />
0.50<br />
2.92<br />
406<br />
CB-0127<br />
9.40<br />
3.30<br />
2.16<br />
0.08<br />
5.72<br />
0.63<br />
2.79<br />
406<br />
CB-0128<br />
15.24<br />
5.59<br />
3.56<br />
0.10<br />
6.35<br />
0.80<br />
4.60<br />
406<br />
CB-0129<br />
7.60<br />
3.30<br />
2.10<br />
0.08<br />
4.32<br />
0.43<br />
2.79<br />
408<br />
CB-0130<br />
8.90<br />
2.80<br />
3.40<br />
0.08<br />
4.29<br />
0.46<br />
6.00<br />
406<br />
CB-0131<br />
8.90<br />
8.12<br />
5.08<br />
0.10<br />
8.71<br />
0.80<br />
4.57<br />
300<br />
CB-0132<br />
8.90<br />
4.40<br />
2.16<br />
0.08<br />
4.30<br />
0.50<br />
1.20<br />
300 (mm)<br />
MOQ : 300 pcs. from CB-0121 to CB-0132<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
76<br />
SHIELDING
COPPER BERYLLIUM FINGER STRIPS<br />
CB-0133<br />
CB-0134<br />
R0.59<br />
3.20±0.3<br />
406(APPROX)<br />
2.40<br />
R6.00<br />
8.90<br />
3.20<br />
0.08<br />
copper beryllium 0.08 mm/ 406 mm<br />
0.46<br />
4.75<br />
copper beryllium 0.08 mm/ 408 mm<br />
CB-0135<br />
CB-0136<br />
380<br />
copper beryllium 0.05 mm/ 380 mm<br />
copper beryllium 0.08 mm/ 363 mm<br />
CB-0137<br />
CB-0138<br />
300<br />
copper beryllium 0.08 mm/ 300 mm<br />
copper beryllium 0.13 mm/ 500 mm<br />
CB-0139<br />
CB-0140<br />
copper beryllium 0.13 mm/ 406 mm<br />
copper beryllium 0.1 mm/ 500 mm<br />
CB-0141<br />
CB-0142<br />
CB-0141<br />
A<br />
13.82<br />
B<br />
6.35<br />
C<br />
3.1<br />
D<br />
0.13<br />
E<br />
5.59<br />
F<br />
0.76<br />
L<br />
406<br />
CB-0142<br />
12.8<br />
7.09<br />
3.1<br />
0.13<br />
5.59<br />
0.76<br />
406<br />
(mm)<br />
77<br />
MOQ : 300 pcs. from CB-0133 to CB-0142<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
COPPER BERYLLIUM FINGER STRIPS<br />
CB-0143<br />
CB-0144<br />
copper beryllium 0.1 mm/ 408 mm<br />
CB-0145<br />
copper beryllium 0.08 mm/ 406 mm<br />
CB-0146<br />
425<br />
copper beryllium 0.1 mm/ 425 mm<br />
copper beryllium 0.1 mm/ 379.2 mm<br />
CB-0147<br />
CB-0148<br />
406<br />
copper beryllium 0.1 mm/ 406 mm<br />
copper beryllium 0.1 mm/ 406 mm<br />
CB-0149<br />
CB-0150<br />
300<br />
copper beryllium 0.18 mm/ 500 mm<br />
copper beryllium 0.15 mm/ 300 mm<br />
CB-0151<br />
CB-0152<br />
300<br />
300<br />
copper beryllium 0.1 mm/ 300 mm<br />
copper beryllium 0.08 mm/ 300 mm<br />
MOQ : 300 pcs. from CB-0143 to CB-0152<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
78<br />
SHIELDING
COPPER BERYLLIUM FINGER STRIPS<br />
CB-0153<br />
CB-0154<br />
copper beryllium 0.15 mm/ 406 mm<br />
copper beryllium 0.25 mm/ 406 mm<br />
CB-0155<br />
CB-0156<br />
copper beryllium 0.08 mm/ 610 mm<br />
copper beryllium 0.1 mm/ 480 mm<br />
CB-0157<br />
copper beryllium 0.13 mm/ 433.2 mm<br />
CB-0158<br />
CB-0161<br />
CB-0158<br />
A<br />
8.9<br />
B<br />
4.26<br />
C<br />
6<br />
D<br />
0.08<br />
E<br />
4.32<br />
F<br />
0.46<br />
G<br />
2.2<br />
H<br />
1.5<br />
L<br />
500<br />
CB-0159<br />
19.8<br />
6.4<br />
13.5<br />
0.13<br />
8.51<br />
1.02<br />
3.8<br />
3.6<br />
610<br />
CB-0160<br />
17<br />
7.9<br />
13.5<br />
0.1<br />
8.51<br />
1.02<br />
3.8<br />
3.6<br />
409<br />
CB-0161<br />
28.7<br />
10.4<br />
19.8<br />
*CB-0160 and CB-0161 are with adhesive tape<br />
0.18<br />
11.67<br />
1.02<br />
5.6<br />
3.6<br />
610<br />
(mm)<br />
MOQ : 300 pcs. from CB-0153 to CB-0161<br />
79<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
COPPER BERYLLIUM FINGER STRIPS<br />
CB-0162<br />
CB-0165<br />
CB-0162<br />
A<br />
9.7<br />
B<br />
3.1<br />
C<br />
3.38<br />
D<br />
0.08<br />
E<br />
4.32<br />
F<br />
0.46<br />
G<br />
3.7<br />
H<br />
1.5<br />
L<br />
406<br />
CB-0163<br />
6.4<br />
2.0<br />
2.24<br />
0.08<br />
4.32<br />
0.46<br />
2<br />
1.5<br />
565<br />
CB-0164<br />
19.3<br />
5.8<br />
3.38<br />
0.1<br />
8.72<br />
0.81<br />
6<br />
2<br />
610<br />
CB-0165<br />
13<br />
CB-0165is with adhesive tape<br />
3.6<br />
3.58<br />
0.08<br />
5.79<br />
0.56<br />
4<br />
1.5<br />
381<br />
(mm)<br />
CB-0166<br />
CB-0172<br />
copper beryllium 0.06 mm/ 138.06 mm<br />
copper beryllium 0.1 mm/ 406 mm<br />
CB-0167<br />
CB-0171<br />
CB-0167<br />
A<br />
29.22<br />
B<br />
29.42<br />
C<br />
12.97<br />
D<br />
0.13<br />
E<br />
11.68<br />
F<br />
1.02<br />
G<br />
14.2<br />
H<br />
3.60<br />
L<br />
406<br />
CB-0168<br />
12.48<br />
9.58<br />
3.28<br />
0.08<br />
5.80<br />
0.50<br />
2.30<br />
0.77<br />
377.75<br />
CB-0169<br />
8.42<br />
6.00<br />
3.03<br />
0.08<br />
4.32<br />
0.46<br />
2.16<br />
1.50<br />
500<br />
CB-0170<br />
11,23<br />
9.40<br />
2.66<br />
0.08<br />
5.79<br />
0.56<br />
2.30<br />
0.75<br />
406<br />
CB-0171<br />
18.70<br />
20.6<br />
10.12<br />
0.08<br />
6.91<br />
1.60<br />
3.60 3.60 500 (mm)<br />
Each shape is slightly different, please check drawing<br />
CB-0170 with adhesive<br />
MOQ : 300 pcs. from CB-0162 to CB-0172<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
80<br />
SHIELDING
SHIELDING<br />
MONOFILAMENT BRAIDED SLEEVING MFS-AG<br />
Features<br />
- Wiring and I/O cables associated with an electronic<br />
device often act as an antenna or receiver that can couple<br />
EMI sources to susceptible equipment nearby. Data<br />
lines carrying broadband signals up to high frequency<br />
ranges, also need to be shielded to minimise radiated<br />
coupling.<br />
- The MFS-AG is a highly flexible, lightweight braided<br />
sleeve made of Polyamide 6.6 with a pure silver coating<br />
that provides attenuation up to 54 dB. This braided sleeve<br />
is easy to mount, selfadjusting to convex contours and<br />
allows insertion of single wires at any place without cutting<br />
the sleeve.<br />
Technical Characteristics<br />
Operating temperatures: -40°C to + 160°C ( -40°F to + 320°F )<br />
Tensile strength:<br />
approx. 2.1 Kg per single monofilament<br />
Number of monofilaments:<br />
depending on the diameter of the sleeve<br />
Diameter of single monofilament: 0.27 ± 0.03 mm ( 0.01“ ± 0.001“ )<br />
Minimum radius of the sleeve:<br />
1 mm<br />
Minimum surface coverage: > 75%<br />
Colour:<br />
metallic<br />
Operating diameter range:<br />
available from 1.5 mm to 115 mm Ø<br />
Combustibility:<br />
not selfextinguishing as empty sleeve***<br />
Toxicity:<br />
all materials are free of halogen, cadmium and<br />
formaldehyde; non toxic<br />
Surface resistivity: < 0.5 W /<br />
Shielding effectiveness:<br />
depending on diameter and frequency<br />
- up to 54 dB as tested to MIL Std 1377 (DIN 47250 T6)<br />
- up to 40 dB as tested to MIL Std 285<br />
Requirements met:<br />
flame extinguished before first measurement<br />
point reached<br />
VDE II B / VDE 0304, part 3 (5.70)<br />
UL-94: 94 V-2, UL standard 94<br />
Airbus Industry Technical Specification<br />
ATS 1000.001, 4.1 and 4,2<br />
***<br />
In case of burning , the silver coating keeps a temperature higher than the self ignition temperature of the Polyamide 6.6<br />
gases. Selfextinguishing cables inside the harness cool the silver down.<br />
Shielding effect<br />
81<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
SHIELDING<br />
MONOFILAMENT BRAIDED SLEEVING MFS-AG<br />
Part.No.<br />
MFS-AG-3/4<br />
MFS-AG-4/5<br />
MFS-AG-6/8<br />
MFS-AG-10/12<br />
MFS-AG-14/16<br />
MFS-AG-16/26<br />
MFS-AG-18/25<br />
MFS-AG-30<br />
MFS-AG-40/45<br />
MFS-AG-50/55<br />
MFS-AG-60/65<br />
MFS-AG- 80<br />
MFS-AG-100<br />
Dimension<br />
mm<br />
mm<br />
mm<br />
mm<br />
mm<br />
mm<br />
mm<br />
mm<br />
mm<br />
mm<br />
mm<br />
mm<br />
mm<br />
from ø<br />
1,5<br />
3<br />
5<br />
7<br />
8<br />
16<br />
18<br />
24<br />
32<br />
32<br />
32<br />
32<br />
50<br />
for round objects<br />
to ø<br />
4<br />
6<br />
11<br />
15<br />
18<br />
26<br />
30<br />
36<br />
47<br />
58<br />
68<br />
85<br />
115<br />
flat width<br />
when delivered<br />
4<br />
5<br />
9<br />
11<br />
17<br />
20<br />
28<br />
30<br />
45<br />
51<br />
57<br />
61<br />
95<br />
number of<br />
filaments<br />
48<br />
64<br />
96<br />
120<br />
160<br />
192<br />
252<br />
292<br />
384<br />
480<br />
600<br />
720<br />
960<br />
length of one<br />
machine hank<br />
over 600m<br />
over 600m<br />
over 600m<br />
400-450m<br />
300-340m<br />
340-360m<br />
300-340m<br />
300-340m<br />
300-340m<br />
300-340m<br />
260-270m<br />
210-250m<br />
140-160m<br />
Dimensioned sketch for round objects<br />
mm<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
82<br />
SHIELDING
GENERAL TERMS OF DELIVERY AND PAYMENT<br />
1. Scope<br />
1.1 The following General Terms of Delivery and<br />
Payment shall be applicable – provided nothing to<br />
the contrary is stipulated in writing – to all of the<br />
deliveries and other performance effected by us.<br />
make up the delivery after the cessation of the<br />
cause of the impediment. There shall be no claims<br />
due to non-delivery or late delivery. This shall<br />
also be applicable if above indicated circumstances<br />
arise once the stipulated delivery period was<br />
already exceeded.<br />
default remains reserved.<br />
6.3 The orderer can only set off the claims of<br />
Kitagawa GmbH against undisputed counterclaims<br />
or counter-claims which have been recognised<br />
by a declaratory judgement.<br />
83<br />
1.2 Deviating General Terms of Business of the<br />
orderer shall not bind us.<br />
1.3 Amendments and/or supplements to the following<br />
terms and to the additionally stipulated<br />
agreements upon the conclusion of the contract<br />
must be made in writing.<br />
1.4 Details in catalogues and brochures as well as<br />
in other documentation are non-binding insofar<br />
as they were not expressly stipulated as binding.<br />
2. Conclusion of the Contract<br />
2.1 The offers of Kitagawa GmbH are made<br />
without obligation.<br />
2.2 A contract between Kitagawa GmbH and the<br />
orderer shall only come into effect in accordance<br />
with the contents of the written confirmation of<br />
order on the part of Kitagawa GmbH or through<br />
the delivery of the goods or the rendering of the<br />
agreed performance by Kitagawa GmbH.<br />
2.3 The orderer shall be bound to its order for<br />
three weeks. Kitagawa GmbH reserves the right to<br />
deviate from the orderer’s specifications in the<br />
acceptance of the order if this is necessary for the<br />
fulfillment of the order and is acceptable for the<br />
contract Partner.<br />
2.4 Kitagawa GmbH shall be entitled to effect an<br />
alteration to the goods at any time without prior<br />
notification insofar as this does not result in any<br />
shortfall of the contractually stipulated characteristics<br />
of the goods and the alteration is reasonable<br />
for the orderer. The alteration of already delivered<br />
contract products cannot be subsequently<br />
demanded.<br />
3. Delivery Terms<br />
3.1 The delivery period of the goods shall be<br />
determined in accordance with the written confirmation<br />
of order of Kitagawa GmbH.<br />
3.2 Indicated delivery periods shall run from the<br />
dispatch of the written confirmation or order. lf the<br />
orderer is obliged to effect advance performance,<br />
then the delivery period shall commence with the<br />
receipt of the contractual advance performance of<br />
the orderer at Kitagawa GmbH.<br />
3.3 If the orderer demands alterations to the contractually<br />
stipulated performance after a written<br />
confirmation of order has been effected, then<br />
Kitagawa GmbH shall be entitled to effect a reasonable<br />
extension to the delivery period if necessary.<br />
3.4 In cases of force majeure, interventions by<br />
sovereign powers, natural disasters, war, revolts,<br />
strikes at its own company, at supply companies<br />
or at carriers, Kitagawa GmbH shall be entitled to<br />
3.5 If a promised delivery date is not met by<br />
Kitagawa GmbH for justifiable reasons, then the<br />
orderer shall be en-titled to set Kitagawa GmbH a<br />
two-week subsequent period after the expiry of<br />
the stipulated delivery period by means of registered<br />
letter. The orderer shall be entitled to withdraw<br />
from the agreement after the fruitless expiry<br />
of the period. Claims for damages, insofar as is<br />
legally permissible, as well as more extensive<br />
rights shall be excluded, provided the delay in<br />
delivery is neither due to intent nor gross negligence<br />
on the part of Kitagawa GmbH. The burden<br />
of proof that intent or gross negligence is not<br />
applicable shall be borne by Kitagawa GmbH.<br />
3.6 Kitagawa GmbH shall be entitled to effect part<br />
deliveries.<br />
4. Shipment and passing of risk<br />
4.1 Kitagawa GmbH shall undertake the shipment<br />
of the goods at the orderer’s expense. Kitagawa<br />
GmbH shall select the forwarder/carrier to the<br />
best of its knowledge, without, however, assuming<br />
corresponding liability. Kitagawa GmbH<br />
shall award the shipping order on the customary<br />
terms in the sector in each case. Transport insurance<br />
shall only be taken out at the orderer's<br />
request and expense.<br />
4.2 Risk shall pass when the goods leave the<br />
warehouse or upon the surrender of the goods to<br />
the forwarder/carrier.<br />
4.3 Any transport damage which occurs must be<br />
asserted by the orderer in due time to the forwarder/carrier<br />
or its insurance company.<br />
5. Prices<br />
The prices are indicated in the respective confirmation<br />
of order of Kitagawa GmbH and are<br />
expressed net in EURO plus the statutory rate of<br />
V.AT. exclusive of packing, freight, postage, delivery<br />
charges etc.<br />
6. Payment Terms<br />
6.1 Insofar as no other payment terms are indicated<br />
in the confirmation of order of Kitagawa<br />
GmbH, the invoices are payable after the invoice<br />
date within 30 days net without any discount.<br />
Decisive for effecting payment on time is the<br />
receipt of the payment at Kitagawa GmbH.<br />
Cheques shall only be accepted in payment.<br />
6.2 lf the orderer is a fully qualified merchant,<br />
then it shall be in default upon the exceeding of<br />
the due date without a separate warning.<br />
Kitagawa GmbH shall be entitled to assert default<br />
interest to the amount of 4 per cent over the respective<br />
discount rate of Deutsche Bundesbank, at<br />
least, however, to the amount of 6 per cent. The<br />
assertion of a more extensive loss caused by<br />
<strong>KE</strong> KITAGAWA<br />
7. Warranty<br />
7.1 Kitagawa warrants for the dura-tion of 6<br />
months that the goods contain no material or<br />
fabrication defects.<br />
7.2 Warranty shall not be effected in the case of<br />
improper utilisation, faulty installation, incorrect<br />
operation etc. No warranty shall similarly be<br />
effected for losses which arise through the operation<br />
of the goods together with such appliances<br />
whose compatibility has not been expressly confirmed<br />
in writing by Kitagawa GmbH.<br />
7.3 The orderer must raise objection to apparent<br />
defects without delay in writing, at the latest,<br />
however, within one week after the receipt of the<br />
goods.<br />
7.4 In the case of defects the warranty shall be<br />
effected at the option of Kitagawa GmbH by subsequent<br />
rectification or substitute delivery. If the<br />
subsequent rectification also fails on the second<br />
attempt or if the second sub-stitute delivery also<br />
contains defects or if Kitagawa GmbH does not<br />
meet its subsequent delivery or substitute delivery<br />
obligation within a reasonable period, then the<br />
orderer shall be enti-tled to a reduction of the<br />
purchase price or rescission of the contract.<br />
7.5 In the case of the violation of a contractual<br />
obligation by Kitagawa GmbH or if a guaranteed<br />
characteristic of the goods should be lacking, liability<br />
shall be restricted to the loss which is to be<br />
expected in accordance with the customary course<br />
of events. More extensive claims on account of the<br />
faulty nature of the goods shall be excluded. This<br />
shall also be applicable to the reparation of consequential<br />
losses and to the violation of ancillary<br />
contractual obligations including culpa in contrahendo.<br />
The prerequi-site for the afore mentioned<br />
exclusions of liability is the proof by Kitagawa<br />
GmbH that neither intent nor gross negligence<br />
was applicable.<br />
The afore mentioned exclusion of liability shall<br />
also be applicable to claims in tort and in connection<br />
with the initiation, conclusion and processing<br />
of a contract, not, however, in the case of claims in<br />
accordance with the Product Liability Act.<br />
8. Retention of Title<br />
8.1 Kitagawa GmbH shall retain title to all goods<br />
until the payment in full of all receivables resulting<br />
from the business relations with Kitagawa<br />
GmbH. If the value of the collateral which is in<br />
existence in favour of Kitagawa GmbH should<br />
exceed the claims against the contract partner by<br />
more than 20 per cent in total, then Kitagawa<br />
GmbH shall be obliged to release collateral at the<br />
request of the contract partner.<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)
GENERAL TERMS OF DELIVERY AND PAYMENT<br />
8.2 The contract partner shall be enti-tled to resell<br />
the goods subject to retention of title in customary<br />
business transactions. The orderer shall not,<br />
however, be entitled to pledge the goods subject<br />
to retention of title or to assign them by way of<br />
security. The orderer already now assigns all<br />
claims to which it is entitled from a future sale of<br />
the goods subject to retention of title against its<br />
purchasers to Kitagawa GmbH by way of security.<br />
Kitagawa GmbH hereby accepts this assignment.<br />
8.3 In the case of the processing or reconstruction<br />
of the goods subject to retention of title by the<br />
orderer, this shall always be effected for Kitagawa<br />
GmbH. If the goods subject to reten-tion of title<br />
are processed with other articles which do not<br />
belong to Kitagawa GmbH, then Kitagawa shall<br />
acquire co-ownership to the new article in proportion<br />
to the value of the goods subject to retention<br />
of title to the other processed articles at the<br />
time of processing. If the orderer sells the goods<br />
subject to retention of title together with other<br />
goods which do not belong to Kitagawa GmbH, or<br />
after joining or processing, then the assignment<br />
shall only be effected to the amount of the outstanding<br />
invoice sum of the respective goods subject<br />
to retention of title.<br />
8.4 The orderer shall be entitled to collect the<br />
assigned receivables in its own name. Kitagawa<br />
GmbH shall, however, be entitled to revoke this<br />
collection authority at any time, especially in the<br />
case of default in payment by the orderer. In the<br />
case of revocation the orderer shall be obliged to<br />
provide Kitagawa GmbH with or to surrender to it<br />
all necessary information and documentation for<br />
the asser-tion of the assigned receivables and to<br />
disclose the assignments to its purchasers. In the<br />
case of default in payment by the orderer<br />
Kitagawa GmbH shall be entitled to notify the<br />
orderer's purchasers of the assignment.<br />
8.5 The orderer shall be obliged to provide<br />
Kitagawa GmbH with information at any time on<br />
the where-abouts of the goods subject to retention<br />
of title and on the receivables<br />
arising from their resale. The orderer shall be<br />
obliged to inform Kitagawa GmbH in writing of a<br />
seizure by a third party of the goods subject to<br />
retention of title or of the receivables assigned to<br />
Kitagawa GmbH and it shall be obliged to draw<br />
the third party’s attention to the rights of<br />
Kitagawa GmbH. The orderer shall furthermore be<br />
obliged to support Kitagawa GmbH upon the<br />
assertion and enforce-ment of its rights against<br />
this third party, especially at its expense to lodge<br />
the necessary immediate remedies/appeals in<br />
order to safeguard the rights of Kitagawa GmbH.<br />
8.6 In the case of default in payment on the part<br />
of the orderer Kitagawa GmbH shall be entitled to<br />
take back the goods subject to retention of title.<br />
The orderer shall accordingly be obliged to surrender<br />
these goods. The taking back of the goods<br />
subject to retention of title does not constitute a<br />
withdrawal from the contract, unless Kitagawa<br />
GmbH expressly states such a withdrawal in writing.<br />
8.7 The orderer shall be obliged to treat the delivered<br />
goods subject to retention of title with care.<br />
lt shall especially be obliged to take out adequate<br />
insurance cover for the goods subject to retention<br />
of title at its own expense against loss or damage<br />
through fire, water, burglary or theft. The orderer<br />
hereby assigns its corresponding insurance claims<br />
to Kitagawa GmbH. Kitagawa GmbH hereby<br />
accepts this assignment and states the reassignment<br />
to the orderer with the proviso that this<br />
shall become effective if and as soon as the retention<br />
of title has expired.<br />
9. Final Provisions<br />
9.1 The orderer shall not be entitled to assign<br />
rights and obligations to third parties arising from<br />
the contract concluded with Kitagawa GmbH<br />
without the prior agreement of Kitagawa GmbH.<br />
9.2 The contractual relations between the contracting<br />
parties shall be subject to the Law of the<br />
Federal Republic of Germany. The provisions of<br />
the Convention on Contracts of the International<br />
Sale of Goods (CISG, Vienna Convention) shall not<br />
apply to the contract concluded with the orderer.<br />
9.3 Place of jurisdiction for all disputes and types<br />
of proceedings arising from or in connection with<br />
the contractual relations between the parties<br />
shall be Darmstadt, Federal Republic of Germany,<br />
provided the orderer is a fully qualified merchant.<br />
9.4 Kitagawa GmbH shall be entitled to store and<br />
to use the personal data to which it has received<br />
access from the business relations with the orderer<br />
under the terms of the German Data<br />
Protection Act for its own business purposes.<br />
9.5 If a provision of these General Terms of<br />
Business or of the contract concluded with the<br />
orderer should be or become ineffective, then this<br />
shall not affect the effectiveness of the remaining<br />
provisions of these General Terms of Business or<br />
of the concluded contract.<br />
<strong>KE</strong> KITAGAWA GmbH<br />
KITAGAWA GmbH · Elbinger Straße 3-5<br />
D-63110 Rodgau-Jügesheim<br />
FR-Germany<br />
Telefon 0 61 06/85 24-0<br />
Telefax 0 61 06/85 24-30(31)<br />
Notice:<br />
The specifications provided in this catalogue are<br />
believed to be accurate and reliable. Kitagawa<br />
GmbH reserves the right to make changes to<br />
specifications to improve manufacturing process,<br />
performance and reliability.<br />
This catalogue is intended for representation only<br />
and is not to form any part of any order.<br />
Engineering specifications are available upon<br />
request.<br />
Any information/specification supplied Kitagawa<br />
GmbH is based upon Kitagawa Industries laboratory<br />
test data and is believed to be reliable. It is<br />
recommended that our products are tested by the<br />
customer to ensure suitability for the intended<br />
application.<br />
If any Kitagawa product is to be used in a life<br />
threatening application(Such areas as Medical,<br />
Automotive and Aerospace etc). The application<br />
must be discussed with the company and written<br />
approval must be obtained.<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)<br />
84
FOR YOUR PERSONAL NOTES<br />
<strong>KE</strong> KITAGAWA<br />
Elbinger Straße 3-5 · D-63110 Rodgau-Jügesheim · Germany · Telefon 0 61 06/85 24 - 0 · Telefax 0 61 06/85 24-30 (31)