Mixed Layout Katalog - FCT
Mixed Layout Katalog - FCT Mixed Layout Katalog - FCT
Coaxial Contacts Koaxialkontakte Technical Data Technische Daten Mechanical Data Mechanische Daten Mating and unmating force (pair of contacts) Steck- und Ziehkräfte (Kontaktpaar) Recommended temperature range Empfohlener Temperaturbereich Mating cycles (Standard) Steckzyklen (Standard) Mating cycles (low cost) Steckzyklen (Low cost) Mechanical Data Mechanische Daten 7 N -55 °C bis 135 °C (-67 °F to 275 °F) 500 200 Electrical Data Elektrische Daten Characteristic impedance Wellenwiderstand Insulation resistance Isolationswiderstand Contact resistance inner conductor Durchgangswiderstand Innenleiter Contact resistance outer conductor Durchgangswiderstand Außenleiter Dielectric withstanding voltage Spannungsfestigkeit Working voltage Betriebsspannung Current rating (DC) Max. Kontaktstrom (DC) Electrical Data Elektrische Daten 50 / 75 10 G 2,7 m 2,7 m 750 V / 50 Hz 250 Vrms 2 A Materials Materialien Outer conductor Außenleiter Inner conductor Innenleiter Retaining clip Halteclip Insulators Isolierteile Materials Materialien Cu alloy Cu Legierung Cu alloy Cu Legierung Cu alloy Cu Legierung PTFE / PBTP / PI 28 ML 12/2008 TECHNISCHE ÄNDERUNGEN VORBEHALTEN - MAßE IN MILLIMETER (INCHES IN KLAMMERN)
VSWR Measurements (Examples) VSWR Messungen (Beispiele) VSWR VSWR The ratio of the maximum to minimum value of the voltage amplitude on a lead is known as the VSWR value. The quotient is a measurement of the quality of the adaptation or of the fluctuation of the resulting voltage surge. In the case of a mismatch, the outward wave is reflected onto the contact point. By superimposing the outward and return waves, a greater difference is obtained between the maximum and minimum voltage than for the outward wave. The VSWR value is 1.0 for a perfect adaptation. The reciprocal value is known as the adaptation factor m. Das Verhältnis von Maximal- zu Minimalwert der Spannungsamplitude auf einer Leitung wird mit VSWR Wert bezeichnet. Der Quotient ist ein Maß für die Qualität der Anpassung bzw. der Welligkeit der resultierenden Spannungswelle. Bei Fehlanpassung wird die hinlaufende Welle an der Kontaktstelle reflektiert. Durch die Überlagerung der hinlaufenden und der rücklaufenden Spannungswelle ergibt sich für die resultierende ein größerer Unterschied zwischen der maximalen und der minimalen Spannungsamplitude als bei der hinlaufenden Welle. Der VSWR-Wert ist im Idealfall der Anpassung gleich 1.0, den Kehrwert bezeichnet man als Anpassungsfaktor m. r: Reflection factor / Reflexionsfaktor m: Adaptation factor / Anpassungsfaktor a: Return loss / Rückflußdämpfung VSWR: Voltage standing wave ratio / Stehwellenverhältnis FMS001P102 / ...S102 (Straight Contacts / gerade Kontakte) FMS015P102/ ...S102 (Right Angled Contacts / abgewinkelte Kontakte) FBM004P170 / ...S170 (Straight Contacts / gerade Kontakte) FMX006P102 / ...S102 (Straight Contacts / gerade Kontakte) DIMENSIONS IN MILLIMETERS - VALUES FOR INCHES IN BRACKETS - TECHNICAL DATA SUBJECT TO CHANGE ML 12/2008 29
- Page 2 and 3: All Products are RoHS compliant. A
- Page 4 and 5: List of Contents Inhaltsverzeichnis
- Page 6 and 7: List of Contents Inhaltsverzeichnis
- Page 8 and 9: Technical Data, FM Connectors Techn
- Page 10 and 11: Test Report, Derating Diagram Testb
- Page 12 and 13: Contact Arrangements (FU/FL Series,
- Page 14 and 15: Mounting and Mating Instructions (A
- Page 16 and 17: Straight Signal Contacts Gerade Sig
- Page 18 and 19: Right Angled Signal Contacts Abgewi
- Page 20 and 21: Mixed Layout Connector with Plastic
- Page 22 and 23: Crimp Connectors Crimp Steckverbind
- Page 24 and 25: Turned Contacts for Crimp Connector
- Page 26 and 27: Code for Special Contacts Nummernsc
- Page 30 and 31: Coaxial Contacts, Mating Area Dimen
- Page 32 and 33: FMX Coaxial Contacts, 50 Ohm, Right
- Page 34 and 35: FMS Coaxial Contacts, 50 Ohm, Strai
- Page 36 and 37: FMS Coaxial Contacts, 75 Ohm, Strai
- Page 38 and 39: Coaxial Contacts, Mating Area Dimen
- Page 40 and 41: Wiresplice Wiresplice 50 Ohm 50 Ohm
- Page 42 and 43: FME Coaxial Contacts, 50 Ohm, Right
- Page 44 and 45: FME Coaxial Contacts, 75 Ohm, Strai
- Page 46 and 47: FME Coaxial Contacts, 75 Ohm, Right
- Page 48 and 49: PCB Hole Pattern for Connectors wit
- Page 50 and 51: PCB Hole Pattern for Connectors wit
- Page 52 and 53: PCB Hole Pattern for Connectors wit
- Page 54 and 55: PCB Hole Pattern for Connectors wit
- Page 56 and 57: PCB Hole Pattern for Connectors wit
- Page 58 and 59: FBM Coaxial Contacts, Mating Area D
- Page 60 and 61: FBM Coaxial Contacts, 50 Ohm, Strai
- Page 62 and 63: FBM Coaxial Contacts, 50 Ohm, Strai
- Page 64 and 65: High Power Contacts Hochstromkontak
- Page 66 and 67: High Power Contacts, Straight Cable
- Page 68 and 69: High Power Contacts, Straight PCB T
- Page 70 and 71: High Power Contacts, Straight PCB T
- Page 72 and 73: Connectors with High Power Contacts
- Page 74 and 75: PCB Hole Pattern for Connectors wit
- Page 76 and 77: PCB Hole Pattern for Connectors wit
VSWR Measurements (Examples)<br />
VSWR Messungen (Beispiele)<br />
VSWR<br />
VSWR<br />
The ratio of the maximum to minimum value of the voltage amplitude on a lead is known as the VSWR value. The quotient is a measurement of the quality<br />
of the adaptation or of the fluctuation of the resulting voltage surge. In the case of a mismatch, the outward wave is reflected onto the contact point. By<br />
superimposing the outward and return waves, a greater difference is obtained between the maximum and minimum voltage than for the outward wave.<br />
The VSWR value is 1.0 for a perfect adaptation. The reciprocal value is known as the adaptation factor m.<br />
Das Verhältnis von Maximal- zu Minimalwert der Spannungsamplitude auf einer Leitung wird mit VSWR Wert bezeichnet. Der Quotient ist ein Maß für<br />
die Qualität der Anpassung bzw. der Welligkeit der resultierenden Spannungswelle. Bei Fehlanpassung wird die hinlaufende Welle an der Kontaktstelle<br />
reflektiert. Durch die Überlagerung der hinlaufenden und der rücklaufenden Spannungswelle ergibt sich für die resultierende ein größerer Unterschied<br />
zwischen der maximalen und der minimalen Spannungsamplitude als bei der hinlaufenden Welle. Der VSWR-Wert ist im Idealfall der Anpassung gleich 1.0,<br />
den Kehrwert bezeichnet man als Anpassungsfaktor m.<br />
r: Reflection factor / Reflexionsfaktor<br />
m: Adaptation factor / Anpassungsfaktor<br />
a: Return loss / Rückflußdämpfung<br />
VSWR: Voltage standing wave ratio / Stehwellenverhältnis<br />
FMS001P102 / ...S102 (Straight Contacts / gerade Kontakte)<br />
FMS015P102/ ...S102 (Right Angled Contacts / abgewinkelte Kontakte)<br />
FBM004P170 / ...S170 (Straight Contacts / gerade Kontakte)<br />
FMX006P102 / ...S102 (Straight Contacts / gerade Kontakte)<br />
DIMENSIONS IN MILLIMETERS - VALUES FOR INCHES IN BRACKETS - TECHNICAL DATA SUBJECT TO CHANGE ML 12/2008<br />
29