03.05.2014 Views

Installation Manual for SMX Modules - OEM Automatic AB

Installation Manual for SMX Modules - OEM Automatic AB

Installation Manual for SMX Modules - OEM Automatic AB

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Installation</strong> <strong>Manual</strong><br />

Two-hand button<br />

Switch type Comment Classification category Classification SIL<br />

2 two-way switch Two-hand button higher Type III C Pl e<br />

SIL3<br />

requirements<br />

2 normally open Two-hand button<br />

monitored<br />

Type III A Pl e<br />

SIL1<br />

Note: With these input elements a fixed pulse assignment takes place, which cannot be<br />

influenced by the user!<br />

Light curtain<br />

Switch type Comment Classification category Classification SIL<br />

2 normally closed Light curtain higher<br />

Pl e SIL 3<br />

requirements<br />

2 normally closed Light curtain monitored Pl e SIL 3<br />

time monitored<br />

1 normally open + 1 Light curtain higher<br />

Pl e SIL 3<br />

normally closed requirements<br />

1 normally open + 1<br />

normally closed time<br />

monitored<br />

Light curtain monitored Pl e SIL 3<br />

Mode selector switch<br />

Switch type Comment Classification category Classification SIL<br />

2 positions Mode selector switch<br />

Pl e SIL 3<br />

monitored<br />

3 positions Mode selector switch<br />

monitored<br />

Pl e SIL 3<br />

Safety note: When changing the status of the switch the SafePLC program to be created<br />

must ensure that the outputs of the module are deactivated (note: Standard 60204-Part1-<br />

Paragraph 9.2.3).<br />

Sensor<br />

Switch type Comment Classification category Classification SIL<br />

1 normally closed Sensor input standard Pl d SIL 2<br />

1 normally open Sensor input standard Pl d SIL 2<br />

2 normally closed Sensor input higher<br />

Pl e SIL 3<br />

requirements<br />

2 normally closed Sensor input monitored Pl e SIL 3<br />

time monitored<br />

1 normally open + 1 Sensor input higher<br />

Pl e SIL 3<br />

normally closed<br />

1 normally open + 1<br />

normally closed time<br />

monitored<br />

requirements<br />

Sensor input monitored Pl e SIL 3<br />

HB-37350-810-01-10E-EN <strong>SMX</strong> installation manual.doc Page 97 of 97