<strong>Installation</strong> <strong>Manual</strong><br />
18 Appendix<br />
18.1 Appendix A<br />
General note:<br />
The individual switches of the following input elements can be assigned to the digital inputs<br />
DI1 to DI8 as desired.<br />
Enable switch<br />
Switch type Comment Classification PI acc. to<br />
EN ISO 13849-1<br />
Classification SIL<br />
acc. to EN 61508<br />
1 normally closed Enable switch standard Pl d SIL 2<br />
1 normally open Enable switch standard Pl d SIL 2<br />
2 normally closed Enable switch higher<br />
Pl e SIL 3<br />
requirements<br />
2 normally closed<br />
time monitored<br />
Enable switch monitored Pl e SIL 3<br />
Emergency Stop<br />
Switch type Comment Classification category Classification SIL<br />
1 normally closed Emergency Stop<br />
Pl d 1) SIL 2<br />
standard<br />
2 normally closed Emergency stop higher<br />
Pl e SIL 3<br />
requirements<br />
2 normally closed time<br />
monitored<br />
Emergency Stop<br />
monitored<br />
Pl e SIL 3<br />
1)<br />
Fault exclusions and boundary conditions acc. to EN 13849-2 must be observed!<br />
Door monitoring<br />
Switch type Comment Classification category Classification SIL<br />
2 normally closed Door monitoring higher<br />
Pl e SIL 3<br />
requirements<br />
2 normally closed Door monitoring monitored Pl e SIL 3<br />
time monitored<br />
1 normally open + 1 Door monitoring higher<br />
Pl e SIL 3<br />
normally closed requirements<br />
1 normally open + 1 Door monitoring monitored SIL 3<br />
normally closed time<br />
monitored<br />
2 normally open + 2 Door monitoring higher<br />
Pl e SIL 3<br />
normally closed requirements<br />
2 normally open + 2 Door monitoring monitored Pl e SIL 3<br />
normally closed time<br />
monitored<br />
3 normally closed Door monitoring higher<br />
Pl e SIL 3<br />
requirements<br />
3 normally closed<br />
time monitored<br />
Door monitoring monitored Pl e SIL 3<br />
HB-37350-810-01-10E-EN <strong>SMX</strong> installation manual.doc Page 96 of 96