03.05.2014 Views

Installation Manual for SMX Modules - OEM Automatic AB

Installation Manual for SMX Modules - OEM Automatic AB

Installation Manual for SMX Modules - OEM Automatic AB

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Installation</strong> <strong>Manual</strong><br />

Alarm code A 4611 / A 4612<br />

Alarm message<br />

Cause<br />

Remedy<br />

OLC2 Teach In position fault<br />

Teach In position outside measuring range<br />

Check transfer position<br />

Alarm code A 4613 / A 4614<br />

Alarm message<br />

Cause<br />

Remedy<br />

OLC1 Teach In ZSC activation fault<br />

The drive moved during Teach In (ZSC fault)<br />

The drive must be stopped when using the Teach In function<br />

Check whether ZSC has already triggered<br />

Alarm code A 4615 / A 4616<br />

Alarm message<br />

Cause<br />

Remedy<br />

OLC2 Teach In ZSC activation fault<br />

The drive moved during Teach In (ZSC fault)<br />

The drive must be stopped when using the Teach In function<br />

Check whether ZSC has already triggered<br />

Alarm code A 4901 / A 4902<br />

Alarm message<br />

Cause<br />

Remedy<br />

CCW and CW rotation monitoring JSS1 activated at the same time<br />

Multiple activation<br />

In programming make sure that only one "Enable" is activated<br />

Alarm code A 4903 / A 4904<br />

Alarm message<br />

Cause<br />

Remedy<br />

CCW and CW rotation monitoring JSS2 activated at the same time<br />

Multiple activation<br />

In programming make sure that only one "Enable" is activated<br />

Alarm code A 5001 / A 5002<br />

Alarm message<br />

Cause<br />

Remedy<br />

Test deactivation of digital inputs 1...14 faulty<br />

Inputs are still active after deactivation<br />

Check wiring of digital inputs<br />

Alarm code A 6701 / A 6702<br />

Alarm message<br />

Cause<br />

Remedy<br />

Timeout fault MET<br />

Input element with time monitoring is faulty<br />

Check wiring of input element<br />

Input element faulty<br />

Alarm code A 6703 / A 6704<br />

Alarm message<br />

Cause<br />

Remedy<br />

Timeout fault MEZ<br />

Two-hand control element with time monitoring is faulty<br />

Check wiring of input element<br />

Input element faulty<br />

HB-37350-810-01-10E-EN <strong>SMX</strong> installation manual.doc Page 74 of 74