<strong>Installation</strong> <strong>Manual</strong><br />

Alarm code A 3507 / A 3508<br />

Fault message Read head fault WCS encoder system axis 1<br />

Cause • WCS read head has detected a fault<br />

Remedy • Read out fault types from WCS encoder system<br />

Alarm code A 4001 / A 4002<br />

Alarm message<br />

Cause<br />

Remedy<br />

CCW and CW rotation monitoring DMC1 activated at the same time<br />

Multiple activation<br />

In programming make sure that only one "Enable" is activated<br />

Alarm code A 4003 / A 4004<br />

Alarm message<br />

Cause<br />

Remedy<br />

CCW and CW rotation monitoring DMC2 activated at the same time<br />

Multiple activation<br />

In programming make sure that only one "Enable" is activated<br />

Alarm code A 4601 / A 4602<br />

Alarm message<br />

Cause<br />

Remedy<br />

Monitoring range left and right of OLC1 activated at the same time<br />

Multiple activation<br />

In programming make sure that only one "Enable" is activated<br />

Alarm code A 4603 / A 4604<br />

Alarm message<br />

Cause<br />

Remedy<br />

Monitoring range left and right of OLC2 activated at the same time<br />

Multiple activation<br />

In programming make sure that only one "Enable" is activated<br />

Alarm code A 4605 / A 4606<br />

Alarm message<br />

Cause<br />

Remedy<br />

OLC1 Teach In status fault<br />

SET and QUIT input have a faulty switching sequence<br />

Check input configuration<br />

Check switching sequence<br />

Alarm code A 4607 / A 4608<br />

Alarm message<br />

Cause<br />

Remedy<br />

OLC2 Teach In status fault<br />

SET and QUIT input have a faulty switching sequence<br />

Check configuration<br />

Check switching sequence<br />

Alarm code A 4609 / A 4610<br />

Alarm message<br />

Cause<br />

Remedy<br />

OLC1 Teach In position fault<br />

Teach In position outside measuring range<br />

Check transfer position<br />

HB-37350-810-01-10E-EN <strong>SMX</strong> installation manual.doc Page 73 of 73