<strong>Installation</strong> <strong>Manual</strong><br />

Alarm code A 3313 / A 3314<br />

Fault message SSI sensor fault<br />

Cause • Encoder step change SSI-value within a cycle too big<br />

• Check encoder wiring<br />

Remedy<br />

• Check encoder configuration<br />

Alarm code A 3321 / A 3322<br />

Alarm message Plausibility fault speed sensing axis 2<br />

The difference between the two speed sensors is higher than the<br />

Cause<br />

configured speed shut-down threshold<br />

Check the theory of the distance once again using the data set in the<br />

encoder configuration<br />

Remedy<br />

Check the speed sensor<br />

Use the SCOPE function to adjust super imposable speed signals<br />

Alarm code A 3323 / A 3324<br />

Alarm message Plausibility fault position sensing axis 2<br />

The difference between the two position sensors is higher than the<br />

Cause<br />

configured incremental shut-down threshold<br />

Check the theory of the distance using the configured data or the<br />

sensor setting<br />

Check the position signal<br />

Remedy<br />

Are all signals correctly connected to the 9-pole encoder plug?<br />

Check the encoder plug <strong>for</strong> correct wiring. Is bridge 1-2 connected to<br />

the 9-pole plug (SSI absolute value encoder)<br />

Use the SCOPE function to adjust super imposable position signals<br />

Alarm code A 3327 / A 3328<br />

Alarm message Plausibility fault position range axis 2<br />

Cause<br />

The current position is outside the configured measuring length<br />

Check the theory of the distance using the configured data or the<br />

sensor setting<br />

Remedy<br />

Check the position signal, if necessary correct the offset<br />

Use the SCOPE function to read out the position and to set into<br />

relation to configured values<br />

Alarm code A 3329 / A 3330<br />

Alarm message Plausibility fault because of faulty speed axis 2<br />

Cause<br />

The current speed is outside the configured maximum speed<br />

The drive moves outside the permissible and configured speed range<br />

Remedy<br />

Check configuration<br />

Use the SCOPE function to analyse the course of speed<br />