03.05.2014 Views

Installation Manual for SMX Modules - OEM Automatic AB

Installation Manual for SMX Modules - OEM Automatic AB

Installation Manual for SMX Modules - OEM Automatic AB

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Installation</strong> <strong>Manual</strong><br />

Alarm code A 3301 / A 3302<br />

Alarm message Plausibility fault speed sensing axis 1<br />

The difference between the two speed sensors is higher than the<br />

Cause<br />

configured speed shut-down threshold<br />

Check the theory of the distance once again using the data set in the<br />

encoder configuration<br />

Remedy<br />

Check the speed sensor<br />

Use the SCOPE function to adjust super imposable speed signals<br />

Alarm code A 3303 / A 3304<br />

Alarm message Plausibility fault position sensing axis 1<br />

The difference between the two position sensors is higher than the<br />

Cause<br />

configured incremental shut-down threshold<br />

Check the theory of the distance using the configured data or the<br />

sensor setting<br />

Check the position signal<br />

Remedy<br />

Are all signals correctly connected to the 9-pole encoder plug?<br />

Check the encoder plug <strong>for</strong> correct wiring. Is bridge 1-2 connected to<br />

the 9-pole plug (SSI absolute value encoder)<br />

Use the SCOPE function to adjust super imposable position signals<br />

Alarm code A 3307 / A 3308<br />

Alarm message Plausibility fault position range axis 1<br />

Cause<br />

The current position is outside the configured measuring length<br />

Check the theory of the distance using the configured data or the<br />

sensor setting<br />

Remedy<br />

Check the position signal, if necessary correct the offset<br />

Use the SCOPE function to read out the position and to set into<br />

relation to configured values<br />

Alarm code A 3309 / A 3310<br />

Alarm message Plausibility fault because of faulty speed axis 1<br />

Cause<br />

The current speed is outside the configured maximum speed<br />

The drive moves outside the permissible and configured speed range<br />

Remedy<br />

Check configuration<br />

Use the SCOPE function to analyse the course of speed<br />

Alarm code A 3311 / A 3312<br />

Alarm message Configuration fault: Acceleration axis 1<br />

Cause<br />

The current acceleration is outside the configured acceleration range<br />

The drive has exceeded the permissible acceleration range<br />

Remedy<br />

Check the configuration of maximum speed<br />

Use the SCOPE function to analyse the course of speed/acceleration<br />

HB-37350-810-01-10E-EN <strong>SMX</strong> installation manual.doc Page 70 of 70

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!