<strong>Installation</strong> <strong>Manual</strong><br />
Alarm code A 3301 / A 3302<br />
Alarm message Plausibility fault speed sensing axis 1<br />
The difference between the two speed sensors is higher than the<br />
Cause<br />
configured speed shut-down threshold<br />
Check the theory of the distance once again using the data set in the<br />
encoder configuration<br />
Remedy<br />
Check the speed sensor<br />
Use the SCOPE function to adjust super imposable speed signals<br />
Alarm code A 3303 / A 3304<br />
Alarm message Plausibility fault position sensing axis 1<br />
The difference between the two position sensors is higher than the<br />
Cause<br />
configured incremental shut-down threshold<br />
Check the theory of the distance using the configured data or the<br />
sensor setting<br />
Check the position signal<br />
Remedy<br />
Are all signals correctly connected to the 9-pole encoder plug?<br />
Check the encoder plug <strong>for</strong> correct wiring. Is bridge 1-2 connected to<br />
the 9-pole plug (SSI absolute value encoder)<br />
Use the SCOPE function to adjust super imposable position signals<br />
Alarm code A 3307 / A 3308<br />
Alarm message Plausibility fault position range axis 1<br />
Cause<br />
The current position is outside the configured measuring length<br />
Check the theory of the distance using the configured data or the<br />
sensor setting<br />
Remedy<br />
Check the position signal, if necessary correct the offset<br />
Use the SCOPE function to read out the position and to set into<br />
relation to configured values<br />
Alarm code A 3309 / A 3310<br />
Alarm message Plausibility fault because of faulty speed axis 1<br />
Cause<br />
The current speed is outside the configured maximum speed<br />
The drive moves outside the permissible and configured speed range<br />
Remedy<br />
Check configuration<br />
Use the SCOPE function to analyse the course of speed<br />
Alarm code A 3311 / A 3312<br />
Alarm message Configuration fault: Acceleration axis 1<br />
Cause<br />
The current acceleration is outside the configured acceleration range<br />
The drive has exceeded the permissible acceleration range<br />
Remedy<br />
Check the configuration of maximum speed<br />
Use the SCOPE function to analyse the course of speed/acceleration<br />
HB-37350-810-01-10E-EN <strong>SMX</strong> installation manual.doc Page 70 of 70