Alarm code A 3177 / A 3178<br />

Alarm message<br />

Cause<br />

Remedy<br />

Faulty 24 V signal on DI10<br />

No permanent 24 V voltage applied to this input<br />

• Check the voltage on the digital input!<br />

• Check wiring<br />

• Check whether Pulse1 or Pulse2 is applied<br />

Alarm code A 3179 / A 3180<br />

Alarm message<br />

Cause<br />

Remedy<br />

Faulty 24 V signal on DI11<br />

No permanent 24 V voltage applied to this input<br />

• Check the voltage on the digital input!<br />

• Check wiring<br />

• Check whether Pulse1 or Pulse2 is applied<br />

Alarm code A 3181 / A 3182<br />

Alarm message<br />

Cause<br />

Remedy<br />

Faulty 24 V signal on DI12<br />

No permanent 24 V voltage applied to this input<br />

• Check the voltage on the digital input!<br />

• Check wiring<br />

• Check whether Pulse1 or Pulse2 is applied<br />

Alarm code A 3183 / A 3184<br />

Alarm message<br />

Cause<br />

Remedy<br />

Faulty 24 V signal on DI13<br />

No permanent 24 V voltage applied to this input<br />

• Check the voltage on the digital input!<br />

• Check wiring<br />

• Check whether Pulse1 or Pulse2 is applied<br />

Alarm code A 3185 / A 3186<br />

Alarm message<br />

Cause<br />

Remedy<br />

Faulty 24 V signal on DI14<br />

No permanent 24 V voltage applied to this input<br />

• Check the voltage on the digital input!<br />

• Check wiring<br />

• Check whether Pulse1 or Pulse2 is applied<br />

Alarm code A 3197 / A 3198<br />

Alarm message Faulty OSSD input test<br />

Cause<br />

OSSD test faulty<br />

Remedy • 24 V check the input voltage on all OSSD inputs<br />

Alarm code A 3209 / A 3210<br />

Fault message<br />

Cause<br />

Remedy<br />

Encoder supply voltage X31 faulty.<br />

• Encoder supply voltage does not comply with configured<br />

threshold<br />

• Component fault in module<br />

• Check configuration!<br />

• Check encoder supply voltage<br />

• Switch device off/on.<br />

HB-37350-810-01-10E-EN <strong>SMX</strong> installation manual.doc Page 68 of 68