Installation Manual for SMX Modules - OEM Automatic AB
Installation Manual for SMX Modules - OEM Automatic AB
Installation Manual for SMX Modules - OEM Automatic AB
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Installation</strong> <strong>Manual</strong><br />
Alarm code A 3081 / A 3082<br />
Alarm message<br />
Cause<br />
Remedy<br />
Pulse2 plausibility fault on expansion inlet EAEx.9<br />
Configured Pulse2 voltage not applied to this input.<br />
• Check the configuration of the digital input acc. to planning and<br />
circuit diagram<br />
• Check wiring<br />
Alarm code A 3083 / A 3084<br />
Alarm message<br />
Cause<br />
Remedy<br />
Faulty 24 V signal on EAEx.9<br />
No permanent 24 V voltage applied to this input<br />
• Check the voltage on the digital input!<br />
• Check wiring<br />
• Check whether Pulse1 or Pulse2 is applied<br />
Alarm code A 3085 / A 3086<br />
Alarm message<br />
Cause<br />
Remedy<br />
Pulse1 plausibility fault on expansion inlet EAEx.10<br />
Configured Pulse2 voltage not applied to this input.<br />
• Check the configuration of the digital input acc. to planning and<br />
circuit diagram<br />
• Check wiring<br />
Alarm code A 3087 / A 3088<br />
Alarm message<br />
Cause<br />
Remedy<br />
Pulse2 plausibility fault on expansion inlet EAEx.10<br />
Configured Pulse2 voltage not applied to this input.<br />
• Check the configuration of the digital input acc. to planning and<br />
circuit diagram<br />
• Check wiring<br />
Alarm code A 3089 / A 3090<br />
Alarm message<br />
Cause<br />
Remedy<br />
Faulty 24 V signal on EAEx.10<br />
No permanent 24 V voltage applied to this input<br />
• Check the voltage on the digital input!<br />
• Check wiring<br />
• Check whether Pulse1 or Pulse2 is applied<br />
Alarm code A 3101 / A 3102<br />
Alarm message<br />
Cause<br />
Remedy<br />
Pulse1 plausibility fault on input DI1<br />
Configured Pulse1 voltage not applied to this input.<br />
• Check the configuration of the digital input acc. to planning and<br />
circuit diagram<br />
• Check wiring<br />
Alarm code A 3103 / A 3104<br />
Alarm message<br />
Cause<br />
Remedy<br />
Pulse1 plausibility fault on input DI2<br />
Configured Pulse1 voltage not applied to this input.<br />
• Check the configuration of the digital input acc. to planning and<br />
circuit diagram<br />
• Check wiring<br />
HB-37350-810-01-10E-EN <strong>SMX</strong> installation manual.doc Page 62 of 62