Alarm code A 3039 / A 3040<br />
Alarm message<br />
Cause<br />
Remedy<br />
Pulse2 plausibility fault on expansion inlet EAEx.2<br />
Configured Pulse2 voltage not applied to this input.<br />
• Check the configuration of the digital input acc. to planning and<br />
circuit diagram<br />
• Check wiring<br />
Alarm code A 3041 / A 3042<br />
Alarm message<br />
Cause<br />
Remedy<br />
Faulty 24 V signal on EAEx.2<br />
No permanent 24 V voltage applied to this input<br />
• Check the voltage on the digital input!<br />
• Check wiring<br />
• Check whether Pulse1 or Pulse2 is applied<br />
Alarm code A 3043 / A 3044<br />
Alarm message<br />
Cause<br />
Remedy<br />
Pulse1 plausibility fault on expansion inlet EAEx.3<br />
Configured Pulse1 voltage not applied to this input.<br />
• Check the configuration of the digital input acc. to planning and<br />
circuit diagram<br />
• Check wiring<br />
Alarm code A 3045 / A 3046<br />
Alarm message<br />
Cause<br />
Remedy<br />
Pulse2 plausibility fault on expansion inlet EAEx.3<br />
Configured Pulse2 voltage not applied to this input.<br />
• Check the configuration of the digital input acc. to planning and<br />
circuit diagram<br />
• Check wiring<br />
Alarm code A 3047 / A 3048<br />
Alarm message<br />
Cause<br />
Remedy<br />
Faulty 24 V signal on EAEx.3<br />
No permanent 24 V voltage applied to this input<br />
• Check the voltage on the digital input!<br />
• Check wiring<br />
• Check whether Pulse1 or Pulse2 is applied<br />
Alarm code A 3049 / A 3050<br />
Alarm message<br />
Cause<br />
Remedy<br />
Pulse1 plausibility fault on expansion inlet EAEx.4<br />
Configured Pulse1 voltage not applied to this input.<br />
• Check the configuration of the digital input acc. to planning and<br />
circuit diagram<br />
• Check wiring<br />
Alarm code A 3051 / A 3052<br />
Alarm message<br />
Cause<br />
Remedy<br />
Pulse2 plausibility fault on expansion inlet EAEx.4<br />
Configured Pulse2 voltage not applied to this input.<br />
• Check the configuration of the digital input acc. to planning and<br />
circuit diagram<br />
• Check wiring<br />
HB-37350-810-01-10E-EN <strong>SMX</strong> installation manual.doc Page 59 of 59