Installation Manual 1 Important notes Definition of individual target groups Project engineers for secure drive systems: Engineers and technicians Assembly, electric installation, maintenance and replacement of devices Maintenance electricians and service technicians Commissioning, operation and configuration: Technicians and engineers 1.1 Definitions The designation SMX is used as generic term for all derivatives from the SMX product range. Wherever this description refers to a certain derivative, the complete designation is used. The term "safe" used in the following text in any case refers to the classification as a safe function for application up to Pl e acc. to EN ISO 13849-1 or SIL3 acc. to EN 61508. The system software "SafePLC" serves the purpose of configuring and programming of the SMX modules. The modules of the SMX series are internally built up of two independent processing units. In the following these are referred to as system A and system B. HB-37350-810-01-10E-EN SMX installation manual.doc Page 4 of 4
Installation Manual 1.2 Co-valid documents Description Configuration of the SMX module for standalone applications without fieldbus interfacing with the program "SafePLC" Validation report for implemented parameterization and PLC-program Reference SafePLC programming manual (System CD) Safety inspection with acceptance protocol Acceptance test TÜV certificate for product modules SMX10 SMX11 SMX12 SMX12A Note: • Thoroughly read the manuals before you start the installation and the commissioning of the SMX module. • Paying attention to the documentation is a prerequisite for trouble-free operation and fulfilment of possible warranty claims. 1.3 Abbreviations used Abbreviation Meaning AC IL ELIA CLK CPU DC DI1..DI14 DIN DO EMU Alternating voltage Instruction list Employer's liability insurance association Clock (cycle) Central Processing Unit Direct voltage Digital Input Deutsches Institut für Normung (German Institute for Standardization) Digital Output Emergency Monitoring Unit HB-37350-810-01-10E-EN SMX installation manual.doc Page 5 of 5
- Page 1 and 2: Installation Manual Installation Ma
- Page 3: Installation Manual 9 SAFETY RELEVA
- Page 7 and 8: Installation Manual 2 Safety regula
- Page 9 and 10: Installation Manual 3.1.2 SMX11 Typ
- Page 11 and 12: Installation Manual 3.1.4 SMX12A Ty
- Page 13 and 14: Installation Manual 3.1.6 Type plat
- Page 15 and 16: Installation Manual 4.2 Installatio
- Page 17 and 18: Installation Manual 4.4 External 24
- Page 19 and 20: Installation Manual 4.6 Connection
- Page 21 and 22: Installation Manual Note: • In th
- Page 23 and 24: Installation Manual 2. Single-chann
- Page 25 and 26: Installation Manual 4.8 Connection
- Page 27 and 28: Installation Manual Attention: The
- Page 29 and 30: Installation Manual 6.2 Connection
- Page 31 and 32: Installation Manual 6.4 Connection
- Page 33 and 34: Installation Manual 8 Sensor type A
- Page 35 and 36: Installation Manual For application
- Page 37 and 38: Installation Manual The test functi
- Page 39 and 40: Installation Manual 10.1.2 Single-p
- Page 41 and 42: Installation Manual 10.1.4 Single-p
- Page 43 and 44: Installation Manual 10.1.6 Wiring o
- Page 45 and 46: Installation Manual 10.2.2 Wiring t
- Page 47 and 48: Installation Manual Response times
- Page 49 and 50: Installation Manual 11 Start-up 11.
- Page 51 and 52: Installation Manual 11.4 Terminal a
- Page 53 and 54: Installation Manual 12 Safety relat
<strong>Installation</strong> <strong>Manual</strong><br />
1.2 Co-valid documents<br />
Description<br />
Configuration of the <strong>SMX</strong> module <strong>for</strong><br />
standalone applications without<br />
fieldbus interfacing with the program<br />
"SafePLC"<br />
Validation report <strong>for</strong> implemented<br />
parameterization and PLC-program<br />
Reference<br />
SafePLC programming manual<br />
(System CD)<br />
Safety inspection with acceptance<br />
protocol<br />
Acceptance test<br />
TÜV certificate <strong>for</strong> product modules<br />
<strong>SMX</strong>10<br />
<strong>SMX</strong>11<br />
<strong>SMX</strong>12<br />
<strong>SMX</strong>12A<br />
Note:<br />
• Thoroughly read the manuals be<strong>for</strong>e you start the installation and the commissioning<br />
of the <strong>SMX</strong> module.<br />
• Paying attention to the documentation is a prerequisite <strong>for</strong> trouble-free operation and<br />
fulfilment of possible warranty claims.<br />
1.3 Abbreviations used<br />
Abbreviation Meaning<br />
AC<br />
IL<br />
ELIA<br />
CLK<br />
CPU<br />
DC<br />
DI1..DI14<br />
DIN<br />
DO<br />
EMU<br />
Alternating voltage<br />
Instruction list<br />
Employer's liability insurance association<br />
Clock (cycle)<br />
Central Processing Unit<br />
Direct voltage<br />
Digital Input<br />
Deutsches Institut für Normung (German Institute <strong>for</strong><br />
Standardization)<br />
Digital Output<br />
Emergency Monitoring Unit<br />
HB-37350-810-01-10E-EN <strong>SMX</strong> installation manual.doc Page 5 of 5