Installation Manual for SMX Modules - OEM Automatic AB
Installation Manual for SMX Modules - OEM Automatic AB Installation Manual for SMX Modules - OEM Automatic AB
Installation Manual 10.1.1 Single-pole switching HISIDE output without testing For the connection of multi-phase applications or for higher current demands external contactors may be used. For a single-pole connection without external test please bear in mind that the SMX module will not recognize bonding of one or several external contacts. The following circuitry is not suitable for safety applications! X21 DO0_P DO0_M DO1_P DO1_M DI1 DI2 DI3 DI4 X14 L+ L- Fig.: Single-pole switching P-output. Not suitable for safety applications! HB-37350-810-01-10E-EN SMX installation manual.doc Page 38 of 38
Installation Manual 10.1.2 Single-pole switching LOSIDE output without testing Analogue to the circuitry shown above, the following example shows a single-pole M-output without testing. The following circuitry is not suitable for safety applications! DO0_P DO0_M DO1_P DO1_M X21 DI1 DI2 DI3 DI4 X14 L+ L- Fig.: Single-pole switching M-output. Not suitable for safety applications! HB-37350-810-01-10E-EN SMX installation manual.doc Page 39 of 39
- Page 1 and 2: Installation Manual Installation Ma
- Page 3 and 4: Installation Manual 9 SAFETY RELEVA
- Page 5 and 6: Installation Manual 1.2 Co-valid do
- Page 7 and 8: Installation Manual 2 Safety regula
- Page 9 and 10: Installation Manual 3.1.2 SMX11 Typ
- Page 11 and 12: Installation Manual 3.1.4 SMX12A Ty
- Page 13 and 14: Installation Manual 3.1.6 Type plat
- Page 15 and 16: Installation Manual 4.2 Installatio
- Page 17 and 18: Installation Manual 4.4 External 24
- Page 19 and 20: Installation Manual 4.6 Connection
- Page 21 and 22: Installation Manual Note: • In th
- Page 23 and 24: Installation Manual 2. Single-chann
- Page 25 and 26: Installation Manual 4.8 Connection
- Page 27 and 28: Installation Manual Attention: The
- Page 29 and 30: Installation Manual 6.2 Connection
- Page 31 and 32: Installation Manual 6.4 Connection
- Page 33 and 34: Installation Manual 8 Sensor type A
- Page 35 and 36: Installation Manual For application
- Page 37: Installation Manual The test functi
- Page 41 and 42: Installation Manual 10.1.4 Single-p
- Page 43 and 44: Installation Manual 10.1.6 Wiring o
- Page 45 and 46: Installation Manual 10.2.2 Wiring t
- Page 47 and 48: Installation Manual Response times
- Page 49 and 50: Installation Manual 11 Start-up 11.
- Page 51 and 52: Installation Manual 11.4 Terminal a
- Page 53 and 54: Installation Manual 12 Safety relat
- Page 55 and 56: Installation Manual 14 Technical da
- Page 57 and 58: Installation Manual 15.2 Alarm list
- Page 59 and 60: Installation Manual Alarm code A 30
- Page 61 and 62: Installation Manual Alarm code A 30
- Page 63 and 64: Installation Manual Alarm code A 31
- Page 65 and 66: Installation Manual Alarm code A 31
- Page 67 and 68: Installation Manual Alarm code A 31
- Page 69 and 70: Installation Manual Alarm code A 32
- Page 71 and 72: Installation Manual Alarm code A 33
- Page 73 and 74: Installation Manual Alarm code A 35
- Page 75 and 76: Installation Manual 15.3 Fatal Erro
- Page 77 and 78: Installation Manual Fatal Error Cod
- Page 79 and 80: Installation Manual Fatal Error Cod
- Page 81 and 82: Installation Manual Fatal Error Cod
- Page 83 and 84: Installation Manual Fatal Error Cod
- Page 85 and 86: Installation Manual Fatal Error Cod
- Page 87 and 88: Installation Manual 16 Encoder type
<strong>Installation</strong> <strong>Manual</strong><br />
10.1.2 Single-pole switching LOSIDE output without testing<br />
Analogue to the circuitry shown above, the following example shows a single-pole M-output<br />
without testing. The following circuitry is not suitable <strong>for</strong> safety applications!<br />
DO0_P<br />
DO0_M<br />
DO1_P<br />
DO1_M<br />
X21<br />
DI1<br />
DI2<br />
DI3<br />
DI4<br />
X14<br />
L+<br />
L-<br />
Fig.: Single-pole switching M-output.<br />
Not suitable <strong>for</strong> safety applications!<br />
HB-37350-810-01-10E-EN <strong>SMX</strong> installation manual.doc Page 39 of 39