<strong>Installation</strong> <strong>Manual</strong><br />

3. Two-channel sensor with cross-shorting test<br />

Cross-shorting as well as connections to DC 24 V and DC 0 V can be detected by using two<br />

independent clock signals on the homogeneous sensor. Only normally closed contacts<br />

should be used <strong>for</strong> safety related applications.<br />

DI1<br />

DI2<br />

DI3<br />

DI4<br />

.<br />

.<br />

.<br />

DI13<br />

DI14<br />

P1<br />

P2<br />

P1<br />

P2<br />

L+<br />

L-<br />

X14<br />

X12<br />

Fig.: two-channel sensor, homogeneous with clock<br />

4.7.2 Expansion module EAE1 … EAE10<br />

Digital inputs Per<strong>for</strong>mance Level Comment<br />

- Single-channel static signal -> auxiliary<br />

EAE1 … EAE10<br />

input<br />

- Two-channel static signal<br />

EAE1 … EAE10 PL e<br />

- Minimum one request/day<br />

- Fault detection only upon request<br />

EAE1 … EAE10 PL d - Less than one request/day<br />

- Single-channel with pulse<br />

EAE1 … EAE10 PL e<br />

- Minimum one request/day<br />

- Fault detection only upon request<br />

- Single-channel with pulse<br />

EAE1 … EAE10 PL d<br />

- Less than one request/day<br />

EAE1 … EAE10 PL e - Two-channel with 2 pulses<br />

HB-37350-810-01-10E-EN <strong>SMX</strong> installation manual.doc Page 24 of 24