2. Single-channel sensor with cross-shorting test<br />
DI1<br />
DI2<br />
DI3<br />
DI4<br />
.<br />
.<br />
.<br />
DI13<br />
DI14<br />
P1<br />
P2<br />
X14<br />
X12<br />
P1<br />
P2<br />
L+<br />
L-<br />
Fig.: Single-channel sensor with cross-shorting test<br />
When using a single-channel sensor with clock one output is connected to the clock output<br />
P1 or P2. The clock must subsequently be assigned to the <strong>SMX</strong>.<br />
The use of a single-channel sensor with clock detects:<br />
short-circuit to supply voltage DC 24 V<br />
short-circuit to DC 0 V<br />
cable interruption (current interruption is secure state!)<br />
However, be cautious in case of a cable short between the two sensor connections, because<br />
this is not detected! A short-circuit between P1 and DI1 is also not detected.<br />
PI d acc. to EN ISO 13849-1 can be achieved by using a suitable switching element and with<br />
cautious wiring of the sensor.<br />
Note:<br />
Pl e acc. to EN ISO 13849-1 is achieved if the short-circuit between DI1 and P1 and the<br />
short-circuit between the sensor connections can be excluded. Here must take care that the<br />
in a fault scenario the switch must be positively opening. The sensor must additionally be<br />
triggered in regular intervals and the safety function requested. Fault exclusions can be achieved<br />
in accordance with EN ISO 13849-2 table D8.<br />