Installation Manual for SMX Modules - OEM Automatic AB

Installation Manual for SMX Modules - OEM Automatic AB Installation Manual for SMX Modules - OEM Automatic AB

oemautomatic.se
from oemautomatic.se More from this publisher
03.05.2014 Views

Installation Manual 3.1.3 SMX12 Type designation Device design Design of module with the following periphery: 2 Sensor interfaces 14 digital inputs, alternatively 4 counting inputs 2 Pulse outputs 2 Relay outputs 2 LOSIDE 2 HISIDE 2 Signal outputs 1 Diagnostic and configuration interface 1 Function button 1 7-segment display 1 Status-LED 14 Status-LEDs for inputs 2 Status-LEDs for pulse outputs 2 Status-LEDs for relay outputs 2 Status-LEDs for HISIDE 1 Backplane bus interface Characteristics of the module: • Logic processing up to Pl e EN ISO 13849-1 or SIL 3 acc. to EN 61508 • Movement monitoring of one or two axes up to Pl e EN ISO 13849-1 or SIL 3 acc. to EN 61508 • Speed monitoring • RPM-monitoring • Standstill monitoring • Sense of rotation monitoring • Secure incremental dimension • Emergency Stop monitoring • Position monitoring • Position range monitoring • Trend range monitoring • Target position monitoring • Open programmable small control system for up to 800 IL instructions • Logic diagram oriented programming • Pulse outputs for cross-shorting detection of digital input signals • Counting inputs as alternatives to the digital inputs • Safety function of external contact monitoring for connected switchgear • Monitored relay outputs for safety relevant functions • Monitored HISIDE/LOWSIDE outputs for safety relevant functions • CAN-communication in connection with the SMX5x for diagnose via backplane bus system Mounting on top hat rail HB-37350-810-01-10E-EN SMX installation manual.doc Page 10 of 10

Installation Manual 3.1.4 SMX12A Type designation Device design Design of module with the following periphery: 2 Sensor interfaces 14 digital inputs, alternatively 4 counting inputs 2 Pulse outputs 2 Relay outputs 2 LOSIDE 2 HISIDE 2 Signal outputs 2x2 Analog inputs 1 Diagnostic and configuration interface 1 Function button 1 7-segment display 1 Status-LED 14 Status-LEDs for inputs 2 Status-LEDs for pulse outputs 2 Status-LEDs for relay outputs 2 Status-LEDs for HISIDE 1 Backplane bus interface Characteristics of the module: • Logic processing up to Pl e EN ISO 13849-1 or SIL 3 acc. to EN 61508 • Movement monitoring of one or two axes up to Pl e EN ISO 13849-1 or SIL 3 acc. to EN 61508 • Speed monitoring • RPM-monitoring • Standstill monitoring • Sense of rotation monitoring • Secure incremental dimension • Emergency Stop monitoring • Position monitoring • Position range monitoring • Trend range monitoring • Target position monitoring • Open programmable small control system for up to 800 IL instructions • Logic diagram oriented programming • Pulse outputs for cross-shorting detection of digital input signals • Secure analog signal monitoring up to SIL 3 acc. to EN 61508 • Counting inputs as alternatives to the digital inputs • Safety function of external contact monitoring for connected switchgear • Monitored relay outputs for safety relevant functions • Monitored HISIDE/LOWSIDE outputs for safety relevant functions HB-37350-810-01-10E-EN SMX installation manual.doc Page 11 of 11

<strong>Installation</strong> <strong>Manual</strong><br />

3.1.3 <strong>SMX</strong>12<br />

Type designation<br />

Device design<br />

Design of module with the following periphery:<br />

2 Sensor interfaces<br />

14 digital inputs, alternatively 4 counting inputs<br />

2 Pulse outputs<br />

2 Relay outputs<br />

2 LOSIDE<br />

2 HISIDE<br />

2 Signal outputs<br />

1 Diagnostic and configuration interface<br />

1 Function button<br />

1 7-segment display<br />

1 Status-LED<br />

14 Status-LEDs <strong>for</strong> inputs<br />

2 Status-LEDs <strong>for</strong> pulse outputs<br />

2 Status-LEDs <strong>for</strong> relay outputs<br />

2 Status-LEDs <strong>for</strong> HISIDE<br />

1 Backplane bus interface<br />

Characteristics of the module:<br />

• Logic processing up to Pl e EN ISO 13849-1 or SIL 3 acc. to EN 61508<br />

• Movement monitoring of one or two axes up to Pl e EN ISO 13849-1 or SIL 3 acc. to<br />

EN 61508<br />

• Speed monitoring<br />

• RPM-monitoring<br />

• Standstill monitoring<br />

• Sense of rotation monitoring<br />

• Secure incremental dimension<br />

• Emergency Stop monitoring<br />

• Position monitoring<br />

• Position range monitoring<br />

• Trend range monitoring<br />

• Target position monitoring<br />

• Open programmable small control system <strong>for</strong> up to 800 IL instructions<br />

• Logic diagram oriented programming<br />

• Pulse outputs <strong>for</strong> cross-shorting detection of digital input signals<br />

• Counting inputs as alternatives to the digital inputs<br />

• Safety function of external contact monitoring <strong>for</strong> connected switchgear<br />

• Monitored relay outputs <strong>for</strong> safety relevant functions<br />

• Monitored HISIDE/LOWSIDE outputs <strong>for</strong> safety relevant functions<br />

• CAN-communication in connection with the <strong>SMX</strong>5x <strong>for</strong> diagnose via backplane bus<br />

system<br />

Mounting on top hat rail<br />

HB-37350-810-01-10E-EN <strong>SMX</strong> installation manual.doc Page 10 of 10