USE OF PSA FOR DESIGN OF EMERGENCY MITIGATION SYSTEMS IN A HYDROGEN PRODUCTION PLANT<br />

Figure 3: Isolation system EAS-200<br />

Once the solution exits the homogenisation tank, the default pump (other pump in standby) will<br />

send the solution through the main line to the sprinklers located in the sulphuric acid decomposition<br />

section. This system is not considered successful if the mixing <strong>of</strong> water and carbonate does not take<br />

place, or there is no flow to the sprinklers.<br />

The electric back-up to this process is independent <strong>of</strong> that <strong>of</strong> the isolation system, the diesel<br />

generator is a different brand and capacity, therefore common cause failure will not be considered<br />

(Fullwood, 2000). The activation <strong>of</strong> the neutralisation process is carried out by the emergency system<br />

EAS-200, and leak detectors AI201 and AI202, as shown in Figure 4.<br />