Theben Catalogue 2014/15. Save energy – Increase comfort.
Time and light control Analogue time switches, Front panel installation/wall installation, tappets 3 SYN 269 h SUL 289 g Description Common functions - Analogue time switch with daily or weekly program (switching disc can be turned) - Tappets - Shortest switching time: 20 minutes or 2 hours - Clock hands for time display - Switching status display SYN 269 h - 1 channel - Without power reserve - Synchronised with mains - Switching preselection - Permanent ON/OFF switch - Simple summer/winter time correction - 32 tappets included in delivery SUL 289 h - 1 channel - With power reserve (NiMH rechargeable battery) - Quartz controlled - Switching preselection - Permanent ON/OFF switch - Simple summer/winter time correction - 32 tappets included in delivery SUL 289 g - 2 channels - With power reserve (NiMH rechargeable battery) - Quartz controlled - 49 tappets included in delivery Product selection Program Number of channels Power reserve Shortest switching times Programmable every Type of contact Operating voltage Type Article number Daily program 1 – 20 min, 2 h 5 min, 30 min Changeover contact 230 V AC SYN 269 h 2690008 3 days 20 min, 2 h 5 min, 30 min Changeover contact 230 V AC SUL 289 h 2890008 2 3 days 20 min, 2 h 5 min, 30 min Changeover contact 230 V AC SUL 289 g 2890033 44 Additional technical data at: www.theben.de/product/ Article number
Time and light control Analogue time switches, Front panel installation/wall installation, tappets Technical data SYN 269 h SUL 289 h SUL 289 g Operating voltage 230 V AC Frequency 50 Hz 50–60 Hz Installation type Front panel installation/wall installation Program Daily program, Weekly program Power reserve – 3 days, full power reserve approx. 3 days after connection to operating voltage 3 Switching capacity at 250 V AC, cos φ = 1 Switching capacity at 250 V AC, cos φ = 0,6 Shortest switching times Programmable every 10 A 2 A 20 min, 2 h 5 min, 30 min Time accuracy at 25 °C Synchronised with mains ≤ ± 1 s/day (quartz) Stand-by consumption 0,9 W 0,5 W Type of protection IP 20 Protection class II according to EN 60 730-1 Ambient temperature –10 °C … +55 °C Accessories Scale drawings 54 69 72 16 104 66 72 Snap-on mounting 72 x 72 ↪ Art.No.: 9070071 Details page 246 65 25 Connection diagrams C1 C1 C2 1 2 3 7 8 1 2 3 4 5 6 7 8 N L L N L L SYN 269 h, SUL 289 h SUL 289 g Additional technical data at: www.theben.de/product/ Article number 45
- Page 1 and 2: Save energy - increase comfort Cata
- Page 3 and 4: ë Efficient distribution Theben st
- Page 5 and 6: News 1 Time and light control Digit
- Page 7 and 8: Theben AG Preface Dear customers an
- Page 9 and 10: Theben - your leading premium suppl
- Page 11 and 12: Its shape resembles a droplet of wa
- Page 13 and 14: With its more elegant design and sl
- Page 15 and 16: News Meteodata 139 KNX 1 More effec
- Page 17 and 18: Time and light control Digital time
- Page 19 and 20: Time and light control Digital time
- Page 21 and 22: Time and light control Digital time
- Page 23 and 24: Time and light control Digital time
- Page 25 and 26: Time and light control Digital time
- Page 27 and 28: Time and light control Digital time
- Page 29 and 30: Time and light control Digital time
- Page 31 and 32: Time and light control Digital time
- Page 33 and 34: Time and light control Digital time
- Page 35 and 36: Time and light control Digital time
- Page 37 and 38: Time and light control Analogue tim
- Page 39 and 40: Time and light control Analogue tim
- Page 41 and 42: Time and light control Analogue tim
- Page 43 and 44: Time and light control Analogue tim
- Page 45: Time and light control Analogue tim
- Page 49 and 50: Time and light control Analogue tim
- Page 51 and 52: Time and light control Analogue tim
- Page 53 and 54: Time and light control Analogue tim
- Page 55 and 56: Time and light control Time relays/
- Page 57 and 58: Time and light control Time relays
- Page 59 and 60: Time and light control Hour counter
- Page 61 and 62: Time and light control Hour counter
- Page 63 and 64: Time and light control Staircase ti
- Page 65 and 66: Time and light control Staircase ti
- Page 67 and 68: Time and light control Staircase ti
- Page 69 and 70: Time and light control Staircase ti
- Page 71 and 72: Time and light control Dimmer Techn
- Page 73 and 74: Time and light control Twilight swi
- Page 75 and 76: Time and light control Twilight swi
- Page 77 and 78: Time and light control Twilight swi
- Page 79 and 80: Time and light control Twilight swi
- Page 81 and 82: Time and light control Twilight swi
- Page 83 and 84: Presence and motion detectors Prese
- Page 85 and 86: Presence and motion detectors Prese
- Page 87 and 88: Presence and motion detectors Prese
- Page 89 and 90: Presence and motion detectors Prese
- Page 91 and 92: Presence and motion detectors Prese
- Page 93 and 94: Presence and motion detectors Prese
- Page 95 and 96: Presence and motion detectors Prese
Time and light control<br />
Analogue time switches, Front panel installation/wall installation, tappets<br />
3<br />
SYN 269 h<br />
SUL 289 g<br />
Description<br />
Common functions<br />
- Analogue time switch with daily or weekly<br />
program (switching disc can be turned)<br />
- Tappets<br />
- Shortest switching time: 20 minutes or<br />
2 hours<br />
- Clock hands for time display<br />
- Switching status display<br />
SYN 269 h<br />
- 1 channel<br />
- Without power reserve<br />
- Synchronised with mains<br />
- Switching preselection<br />
- Permanent ON/OFF switch<br />
- Simple summer/winter time correction<br />
- 32 tappets included in delivery<br />
SUL 289 h<br />
- 1 channel<br />
- With power reserve<br />
(NiMH rechargeable battery)<br />
- Quartz controlled<br />
- Switching preselection<br />
- Permanent ON/OFF switch<br />
- Simple summer/winter time correction<br />
- 32 tappets included in delivery<br />
SUL 289 g<br />
- 2 channels<br />
- With power reserve<br />
(NiMH rechargeable battery)<br />
- Quartz controlled<br />
- 49 tappets included in delivery<br />
Product selection<br />
Program<br />
Number of<br />
channels<br />
Power<br />
reserve<br />
Shortest<br />
switching times<br />
Programmable<br />
every<br />
Type of contact<br />
Operating<br />
voltage<br />
Type<br />
Article<br />
number<br />
Daily program 1 <strong>–</strong> 20 min, 2 h 5 min, 30 min Changeover contact 230 V AC SYN 269 h 2690008<br />
3 days 20 min, 2 h 5 min, 30 min Changeover contact 230 V AC SUL 289 h 2890008<br />
2 3 days 20 min, 2 h 5 min, 30 min Changeover contact 230 V AC SUL 289 g 2890033<br />