Theben Catalogue 2014/15. Save energy – Increase comfort.
3 A special form of stability Stability is a precondition for innovative power, Theben offers both. Everyone benefits, our customers, our partners and our employees. Because only those with the required resource can invest in innovation, but also the solid foundations of a company create climate of trust. This kind of predictability has characterised Theben’s success for many years. Behind that lies a local virtue, one that is of special importance in times like these, solidarity. 34 Additional technical data at: www.theben.de/product/ Article number
Time and light control Analogue time switches Analogue time switches Program Number of channels Type of contact Power reserve Shortest switching times Programmable every Type of connection Type Page DIN rail, 1 module Daily program 1 NO contact – 15 min 15 min Screw terminals SYN 160 a 36 3 days 15 min 15 min Screw terminals SUL 180 a 36 DIN rail, 3 modules Weekly program 1 NO contact 3 days 2 h 2 h Screw terminals MEM 190 a 36 60 minutes program 1 Changeover contact Daily program 1 Changeover contact – 37,5 s 37,5 s DuoFix spring terminals SYN 151 h 38 – 15 min 15 min DuoFix spring terminals SYN 161 d 38 200 hours 15 min 15 min DuoFix spring terminals SUL 181 d 38 3 Weekly program 1 Changeover contact Daily program 2 Changeover contact 200 hours 2 h 2 h DuoFix spring terminals SUL 191w 38 3 days 30 min 15 min Screw terminals SUL 188 g 40 Daily/weekly program with 1/2 day OFF function 1 Changeover contact 3 days 45 min, 12 h 15 min, 12 h Screw terminals SUL 188 hw 40 Front panel installation/wall installation Daily program 1 Changeover contact – 15 min 15 min Screw terminals SYN 169 s 42 3 days 15 min 15 min Screw terminals SUL 189 s 42 Daily program 1 Changeover contact 2 Changeover contact – 20 min, 2 h 5 min, 30 min Screw terminals SYN 269 h 44 3 days 20 min, 2 h 5 min, 30 min Screw terminals SUL 289 h 44 3 days 20 min, 2 h 5 min, 30 min Screw terminals SUL 289 g 44 60 minutes program Daily/weekly program with 1/2 day OFF function 1 Changeover contact 1 Changeover contact – 1,25 min 18,5 s Screw terminals TM 179 h 46 3 days 30 min, 12 h 15 min, 12 h Screw terminals SUL 189 hw 46 Wall installation/3-point mounting Daily program 2 Changeover contact 6 days 20 min 5 min Screw terminals SUL 285/2 T 48 Plug-in Daily program 1 NO contact – 15 min 15 min Plug-in theben-timer 26 49 theben-timer 26 IP44 49 Weekly program 1 NO contact – 2 h 2 h Plug-in theben-timer 27 49 Surface-mounted Daily and defrost program 2 Changeover contact – 2 min, 1 h 1 min, 1 h Screw terminals FRI 77 g 50 Drive with quick fastening for DIN rail Daily and defrost program 1 Changeover contact 2 Changeover contact – 2 min, 1 h 1 min, 1 h Screw terminals FRI 77 h-2 50 – 2 min, 1 h 1 min, 1 h Screw terminals FRI 77 g-2 50 35
- Page 1 and 2: Save energy - increase comfort Cata
- Page 3 and 4: ë Efficient distribution Theben st
- Page 5 and 6: News 1 Time and light control Digit
- Page 7 and 8: Theben AG Preface Dear customers an
- Page 9 and 10: Theben - your leading premium suppl
- Page 11 and 12: Its shape resembles a droplet of wa
- Page 13 and 14: With its more elegant design and sl
- Page 15 and 16: News Meteodata 139 KNX 1 More effec
- Page 17 and 18: Time and light control Digital time
- Page 19 and 20: Time and light control Digital time
- Page 21 and 22: Time and light control Digital time
- Page 23 and 24: Time and light control Digital time
- Page 25 and 26: Time and light control Digital time
- Page 27 and 28: Time and light control Digital time
- Page 29 and 30: Time and light control Digital time
- Page 31 and 32: Time and light control Digital time
- Page 33 and 34: Time and light control Digital time
- Page 35: Time and light control Digital time
- Page 39 and 40: Time and light control Analogue tim
- Page 41 and 42: Time and light control Analogue tim
- Page 43 and 44: Time and light control Analogue tim
- Page 45 and 46: Time and light control Analogue tim
- Page 47 and 48: Time and light control Analogue tim
- Page 49 and 50: Time and light control Analogue tim
- Page 51 and 52: Time and light control Analogue tim
- Page 53 and 54: Time and light control Analogue tim
- Page 55 and 56: Time and light control Time relays/
- Page 57 and 58: Time and light control Time relays
- Page 59 and 60: Time and light control Hour counter
- Page 61 and 62: Time and light control Hour counter
- Page 63 and 64: Time and light control Staircase ti
- Page 65 and 66: Time and light control Staircase ti
- Page 67 and 68: Time and light control Staircase ti
- Page 69 and 70: Time and light control Staircase ti
- Page 71 and 72: Time and light control Dimmer Techn
- Page 73 and 74: Time and light control Twilight swi
- Page 75 and 76: Time and light control Twilight swi
- Page 77 and 78: Time and light control Twilight swi
- Page 79 and 80: Time and light control Twilight swi
- Page 81 and 82: Time and light control Twilight swi
- Page 83 and 84: Presence and motion detectors Prese
- Page 85 and 86: Presence and motion detectors Prese
3<br />
A special form of stability<br />
Stability is a precondition for innovative power, <strong>Theben</strong> offers both.<br />
Everyone benefits, our customers, our partners and our employees.<br />
Because only those with the required resource can invest in innovation,<br />
but also the solid foundations of a company create climate of trust. This<br />
kind of predictability has characterised <strong>Theben</strong>’s success for many years.<br />
Behind that lies a local virtue, one that is of special importance in times<br />
like these, solidarity.<br />
34<br />
Additional technical data at: www.theben.de/product/ Article number