Theben Catalogue 2014/15. Save energy – Increase comfort.

28.04.2014 Views

3 A special form of stability Stability is a precondition for innovative power, Theben offers both. Everyone benefits, our customers, our partners and our employees. Because only those with the required resource can invest in innovation, but also the solid foundations of a company create climate of trust. This kind of predictability has characterised Theben’s success for many years. Behind that lies a local virtue, one that is of special importance in times like these, solidarity. 34 Additional technical data at: www.theben.de/product/ Article number

Time and light control Analogue time switches Analogue time switches Program Number of channels Type of contact Power reserve Shortest switching times Programmable every Type of connection Type Page DIN rail, 1 module Daily program 1 NO contact 15 min 15 min Screw terminals SYN 160 a 36 3 days 15 min 15 min Screw terminals SUL 180 a 36 DIN rail, 3 modules Weekly program 1 NO contact 3 days 2 h 2 h Screw terminals MEM 190 a 36 60 minutes program 1 Changeover contact Daily program 1 Changeover contact 37,5 s 37,5 s DuoFix spring terminals SYN 151 h 38 15 min 15 min DuoFix spring terminals SYN 161 d 38 200 hours 15 min 15 min DuoFix spring terminals SUL 181 d 38 3 Weekly program 1 Changeover contact Daily program 2 Changeover contact 200 hours 2 h 2 h DuoFix spring terminals SUL 191w 38 3 days 30 min 15 min Screw terminals SUL 188 g 40 Daily/weekly program with 1/2 day OFF function 1 Changeover contact 3 days 45 min, 12 h 15 min, 12 h Screw terminals SUL 188 hw 40 Front panel installation/wall installation Daily program 1 Changeover contact 15 min 15 min Screw terminals SYN 169 s 42 3 days 15 min 15 min Screw terminals SUL 189 s 42 Daily program 1 Changeover contact 2 Changeover contact 20 min, 2 h 5 min, 30 min Screw terminals SYN 269 h 44 3 days 20 min, 2 h 5 min, 30 min Screw terminals SUL 289 h 44 3 days 20 min, 2 h 5 min, 30 min Screw terminals SUL 289 g 44 60 minutes program Daily/weekly program with 1/2 day OFF function 1 Changeover contact 1 Changeover contact 1,25 min 18,5 s Screw terminals TM 179 h 46 3 days 30 min, 12 h 15 min, 12 h Screw terminals SUL 189 hw 46 Wall installation/3-point mounting Daily program 2 Changeover contact 6 days 20 min 5 min Screw terminals SUL 285/2 T 48 Plug-in Daily program 1 NO contact 15 min 15 min Plug-in theben-timer 26 49 theben-timer 26 IP44 49 Weekly program 1 NO contact 2 h 2 h Plug-in theben-timer 27 49 Surface-mounted Daily and defrost program 2 Changeover contact 2 min, 1 h 1 min, 1 h Screw terminals FRI 77 g 50 Drive with quick fastening for DIN rail Daily and defrost program 1 Changeover contact 2 Changeover contact 2 min, 1 h 1 min, 1 h Screw terminals FRI 77 h-2 50 2 min, 1 h 1 min, 1 h Screw terminals FRI 77 g-2 50 35

3<br />

A special form of stability<br />

Stability is a precondition for innovative power, <strong>Theben</strong> offers both.<br />

Everyone benefits, our customers, our partners and our employees.<br />

Because only those with the required resource can invest in innovation,<br />

but also the solid foundations of a company create climate of trust. This<br />

kind of predictability has characterised <strong>Theben</strong>’s success for many years.<br />

Behind that lies a local virtue, one that is of special importance in times<br />

like these, solidarity.<br />

34<br />

Additional technical data at: www.theben.de/product/ Article number

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!