Living <strong>comfort</strong> control, Multifunction display<br />

Description<br />

LUXOR 426<br />

- Central display and control unit for the<br />

LUXOR system<br />

- Time, weekday, date as well as central and<br />

automatic functions are displayed<br />

- Current weather conditions are displayed as<br />

well as min./max. values<br />

- Display with back-lighting<br />

- Favourite sites can be selected from 6 pages<br />

- 8 channel time switch<br />

- Heating temperature reduction in combination<br />

with a RAMSES room thermostat<br />

- Manual switching on the device for central<br />

and group functions as well as manual and<br />

automatic mode<br />

- Daily and weekly programs<br />

- Astronomical program (dependent on sunrise<br />

and sunset)<br />

- Freely programmable switching times as well<br />

as pre-programmed astronomical switching<br />

times<br />

- Offset setting ± 120 min<br />

- Easy location input via city list<br />

- Individual link of time switch channels with<br />

the outputs<br />

- Time controlled positioning of drives<br />

(LUXOR 408 S/409 S) as well as transmission<br />

of dimming values (LUXOR 405)<br />

as percentage values<br />

- Blocking times for suppression of brightness<br />

or twilight signals from sensor module<br />

(LUXOR 411)<br />

- Astronomical blocking times for time shifts<br />

for moving shutters/awnings up and down<br />

- Automatic changeover summer/winter time<br />

- PIN code<br />

- Installation in flush-mounted socket<br />

Product selection<br />

Type<br />

Article number<br />

Technical data<br />

LUXOR 426<br />

LUXOR 426 4260000<br />

Operating voltage<br />

Frequency<br />

Installation type<br />

Stand-by consumption<br />

230 V AC<br />

50 Hz<br />

Wall installation or on flush-mounted socket<br />

1,1 W<br />

Number of channels 8<br />

Connection for COM<br />

Number of memory<br />

locations<br />

Program<br />

EIB/KNX bus line type YCYM or Y(ST)Y or<br />

communication line J-Y(ST)Y/length up to 100 m<br />

350<br />

Weekly program<br />

Ambient temperature <strong>–</strong>5 °C … +45 °C<br />

Type of protection IP 20<br />

Protection class II according to EN 60 335<br />

Scale drawings<br />

45,6<br />

18,1<br />

128 4<br />

93,4<br />

13<br />

236<br />

Additional technical data at: www.theben.de/product/ Article number