Theben Catalogue 2014/15. Save energy – Increase comfort.
Home and building control KNX, Motion detectors SPHINX 105-300 KNX Description - Motion detector (PIR) - 2 channels - For controlling lighting in outdoor areas - Blended light measurement suitable for the control of fl uorescent, incandescent and halogen lamps - Adjustable sensor head - Additional creep under protection via remote control - Detection area can be limited using enclosed segments - Settings per ETS: Brightness range and switch-off delay - Set point adjustment of brightness either via object or potentiometer - Following functions: Lighting ON/OFF, time functions, locking the motion detector - Lighting control with adjustable light threshold value and adjustable switch-off delay - Memorising of current brightness value possible via remote control - Setting controls protected against manipulation - Single-handed plug-in installation with captive screws Product selection Installation type Type Article number Wall and ceiling installation SPHINX 105-300 KNX 1059203 Technical data Operating voltage KNX Setting range brightness Light switch-off delay SPHINX 105-300 KNX Bus voltage,
Home and building control KNX, Motion detectors SPHINX 331 S KNX Description - Motion detector (PIR) - Automatic lighting control based on presence and brightness - Integrated bus coupling - With constant light control - Lighting control „movement-dependent only „ and „movement and brightness dependent“ - Continuous constant light control/movement-dependent - Following functions: e.g. lighting ON/ OFF, shutters/blinds UP/DOWN, time functions (switch-off delay), locking the motion detector, dimming values, dimming UP/DOWN, Master/Slave function - Flush fi tting design (projects 4 mm from ceiling) SPHINX 331 S KNX - 1 channel SPHINX 332 S KNX - 2 channels - Additional programming keys can activate the physical address via a programming magnet (if programming is being executed after installation) Product selection Technical data Installation type Type Article number SPHINX 331 S KNX SPHINX 332 S KNX Ceiling installation SPHINX 331 S KNX 1079215 SPHINX 332 S KNX 1079216 Operating voltage KNX Setting range brightness Light switch-off delay Bus voltage, ≤10 mA 0–700 lx 1 s–120 min Ambient temperature –5 °C … +45 °C Protection class II according to EN 60 730-1 Type of protection IP 40 (when fi tted) Scale drawings Detection range 68,7 4 30 3,6 76 Ø 76 Ø 76 Ø 36,9 Ø 58,4 Ø 64/68 3,5 m ■ Walking Mounting height 2.5 m 12 Additional technical data at: www.theben.de/product/ Article number 201
- Page 151 and 152: Climate control Clock thermostats,
- Page 153 and 154: Climate control Clock thermostats,
- Page 155 and 156: Climate control Clock thermostats,
- Page 157 and 158: Climate control Clock thermostats,
- Page 159 and 160: Climate control Clock thermostats,
- Page 161 and 162: Climate control Clock thermostats,
- Page 163 and 164: Climate control Clock thermostats,
- Page 165 and 166: Climate control Clock thermostats,
- Page 167 and 168: Climate control Room thermostats Ro
- Page 169 and 170: Climate control Room thermostats, M
- Page 171 and 172: Climate control Room thermostats, M
- Page 173 and 174: Climate control Room thermostats, E
- Page 175 and 176: Climate control Sensor technology S
- Page 177 and 178: Climate control Hygrostat Descripti
- Page 179 and 180: Home and building control KNX KNX D
- Page 181 and 182: Home and building control KNX, Swit
- Page 183 and 184: Home and building control KNX, Swit
- Page 185 and 186: Home and building control KNX, 1-10
- Page 187 and 188: Home and building control KNX, Dimm
- Page 189 and 190: Home and building control KNX, Dimm
- Page 191 and 192: Home and building control KNX, Blin
- Page 193 and 194: Home and building control KNX, HVAC
- Page 195 and 196: Home and building control KNX, HVAC
- Page 197 and 198: Home and building control KNX, HVAC
- Page 199 and 200: Home and building control KNX, HVAC
- Page 201: Home and building control KNX, HVAC
- Page 205 and 206: Home and building control KNX, Pres
- Page 207 and 208: Home and building control KNX, Pres
- Page 209 and 210: Home and building control KNX, Pres
- Page 211 and 212: Home and building control KNX, Pres
- Page 213 and 214: Home and building control KNX, Pres
- Page 215 and 216: Home and building control KNX, Weat
- Page 217 and 218: Home and building control KNX, Weat
- Page 219 and 220: Home and building control KNX, Weat
- Page 221 and 222: Home and building control KNX, Digi
- Page 223 and 224: Home and building control KNX, Time
- Page 225 and 226: Home and building control KNX, Gate
- Page 227 and 228: Home and building control KNX, Syst
- Page 229 and 230: Home and building control KNX, Disp
- Page 231 and 232: Home and building control Living co
- Page 233 and 234: Home and building control Living co
- Page 235 and 236: Home and building control Living co
- Page 237 and 238: Home and building control Living co
- Page 239 and 240: Home and building control Living co
- Page 241 and 242: Home and building control Living co
- Page 243 and 244: Home and building control Controlle
- Page 245 and 246: Home and building control Controlle
- Page 247 and 248: Home and building control Controlle
- Page 249 and 250: Accessories Description Suitable fo
- Page 251 and 252: Accessories Description Suitable fo
Home and building control<br />
KNX, Motion detectors<br />
SPHINX 331 S KNX<br />
Description<br />
- Motion detector (PIR)<br />
- Automatic lighting control based on presence<br />
and brightness<br />
- Integrated bus coupling<br />
- With constant light control<br />
- Lighting control „movement-dependent only<br />
„ and „movement and brightness dependent“<br />
- Continuous constant light control/movement-dependent<br />
- Following functions: e.g. lighting ON/ OFF,<br />
shutters/blinds UP/DOWN, time functions<br />
(switch-off delay), locking the motion detector,<br />
dimming values, dimming UP/DOWN,<br />
Master/Slave function<br />
- Flush fi tting design (projects 4 mm from<br />
ceiling)<br />
SPHINX 331 S KNX<br />
- 1 channel<br />
SPHINX 332 S KNX<br />
- 2 channels<br />
- Additional programming keys can activate<br />
the physical address via a programming<br />
magnet (if programming is being executed<br />
after installation)<br />
Product selection<br />
Technical data<br />
Installation type Type Article number<br />
SPHINX 331 S KNX<br />
SPHINX 332 S KNX<br />
Ceiling installation SPHINX 331 S KNX 1079215<br />
SPHINX 332 S KNX 1079216<br />
Operating voltage KNX<br />
Setting range brightness<br />
Light switch-off delay<br />
Bus voltage, ≤10 mA<br />
0<strong>–</strong>700 lx<br />
1 s<strong>–</strong>120 min<br />
Ambient temperature <strong>–</strong>5 °C … +45 °C<br />
Protection class II according to EN 60 730-1<br />
Type of protection<br />
IP 40 (when fi tted)<br />
Scale drawings<br />
Detection range<br />
68,7<br />
4 30 3,6<br />
76<br />
Ø 76<br />
Ø 76<br />
Ø 36,9<br />
Ø 58,4<br />
Ø 64/68<br />
3,5 m<br />
■ Walking<br />
Mounting height 2.5 m<br />
12<br />
Additional technical data at: www.theben.de/product/ Article number 201