Theben Catalogue 2014/15. Save energy – Increase comfort.

28.04.2014 Views

Climate control Clock thermostats, Analogue battery version, Analogue 230 V RAMSES 784 RAMSES 784 HF Set 1 RAMSES 721 Description 9 Common functions - Analogue clock thermostat with a low profi le design for time-dependent monitoring and control of room temperature - Operating point and electronic recirculation are set from the front - Party switch and program display - Electronic temperature control - Selector switch for operating mode: continuous reduced temperature, continuous normal temperature, automatic mode, frost and plant protection +6 °C RAMSES 784 - Battery version - Tappet program disc with daily or weekly program - Normal and reduced temperature can be set separately - Quartz mechanism - Battery monitoring with battery replacement indicator via fl ashing LED - Silting and pump protection function (option) RAMSES 784 HF Set 1 - Radio-controlled system for room temperature control - Consisting of one analogue clock thermostat RAMSES 784 HF and one REC 1 receiver (DIN rail) with a two-way switch 6 (1) A/250 V DC - Tappet program disc with daily or weekly program - RAMSES 784 HF battery version - REC 1 mains version - Normal and reduced temperature can be set separately RAMSES 722 - Mains version - Tappet program disc with daily or weekly program - Synchronous motor drive - Normal and reduced temperature can be set separately RAMSES 782 - Mains version - Tappet program disc with daily or weekly program - Quartz mechanism, 3 day power reserve - Normal and reduced temperature can be set separately RAMSES 721 - Mains version - Tappet program disc with daily program - Synchronous motor drive - Normal temperature can be set - Reduced temperature approx. 5 K lower in relation to the set comfort temperature - Without selector switch RAMSES 725 As RAMSES 722, but: - Reduced temperature can be set - Central control of reduced temperature as per time program Product selection Type of contact Setting range temperature Power reserve Type of connection Program Operating voltage Type Article number Changeover contact +10 °C … +30 °C 2/3-way conductors Daily/weekly program 2 AA batteries RAMSES 784 7840030 Radio controlled Daily/weekly program 2 AA batteries RAMSES 784 HF Set 1 7849407 3-/4-conductors Daily/weekly program 230 V AC RAMSES 722 7220030 3 days 3-/4-conductors Daily/weekly program 230 V AC RAMSES 782 7820030 3-/4-conductors Daily program 230 V AC RAMSES 721 7210030 Daily/weekly program 230 V AC RAMSES 725 7250030 162 Additional technical data at: www.theben.de/product/ Article number

Climate control Clock thermostats, Analogue battery version, Analogue 230 V Technical data RAMSES 784 RAMSES 784 HF Set 1 RAMSES 722 RAMSES 782 RAMSES 721 RAMSES 725 Operating voltage 2 AA batteries 230 V AC Frequency 50 Hz 5060 Hz 50 Hz Type of contact Changeover contact Program Daily/weekly program Daily program Daily/weekly program Switching capacity 6 A (at 250 V AC, cos φ = 1), 1 A (at 250 V AC, cos φ = 0.6) Switching differential 0,41,2 K 01,2 K 0,41,2 K 1,5 K Switching output Potential-free Potential-free, not for SELV Setting range temperature +10 °C … +30 °C Shortest switching times 20 min, 120 min 20 min 20 min, 120 min Programmable every 5 min, 30 min 5 min 5 min, 30 min Time accuracy at 25 °C ≤ ± 1 s/day (quartz) Synchronised with mains ≤ ± 1 s/day (quartz) Synchronised with mains Power reserve 3 days Stand-by consumption 1,1 W 1,7 W 1,3 W 1,1 W 1,3 W 1,4 W Type of protection IP 20 Protection class II according to EN 60 730-1 Accessories Scale drawings Connection diagrams Actuator ALPHA 4 230 V Details page 255 29,5 L N 7 8 Actuator ALPHA 4 24 V Details page 255 90 Adapter RAMSES 72x/78x Details page 253 150 35,5 C1 1 2 3 C1 9 N L L RAMSES 784 HF Set 1 Connection diagrams 1 2 3 1 2 3 1 2 3 1 2 3 4 5 4 5 + - + - N L L N LL N L L N LL RAMSES 784 RAMSES 784 RAMSES 722, RAMSES 782, RAMSES 721, RAMSES 725 RAMSES 722, RAMSES 782, RAMSES 721, RAMSES 725 Additional technical data at: www.theben.de/product/ Article number 163

Climate control<br />

Clock thermostats, Analogue battery version, Analogue 230 V<br />

RAMSES 784 RAMSES 784 HF Set 1 RAMSES 721<br />

Description<br />

9<br />

Common functions<br />

- Analogue clock thermostat with a low profi le<br />

design for time-dependent monitoring and<br />

control of room temperature<br />

- Operating point and electronic recirculation<br />

are set from the front<br />

- Party switch and program display<br />

- Electronic temperature control<br />

- Selector switch for operating mode: continuous<br />

reduced temperature, continuous<br />

normal temperature, automatic mode, frost<br />

and plant protection +6 °C<br />

RAMSES 784<br />

- Battery version<br />

- Tappet program disc with daily or weekly<br />

program<br />

- Normal and reduced temperature can be set<br />

separately<br />

- Quartz mechanism<br />

- Battery monitoring with battery replacement<br />

indicator via fl ashing LED<br />

- Silting and pump protection function (option)<br />

RAMSES 784 HF Set 1<br />

- Radio-controlled system for room temperature<br />

control<br />

- Consisting of one analogue clock thermostat<br />

RAMSES 784 HF and one REC 1 receiver (DIN<br />

rail) with a two-way switch 6 (1) A/250 V DC<br />

- Tappet program disc with daily or weekly<br />

program<br />

- RAMSES 784 HF battery version<br />

- REC 1 mains version<br />

- Normal and reduced temperature can be set<br />

separately<br />

RAMSES 722<br />

- Mains version<br />

- Tappet program disc with daily or weekly<br />

program<br />

- Synchronous motor drive<br />

- Normal and reduced temperature can be set<br />

separately<br />

RAMSES 782<br />

- Mains version<br />

- Tappet program disc with daily or weekly<br />

program<br />

- Quartz mechanism, 3 day power reserve<br />

- Normal and reduced temperature can be set<br />

separately<br />

RAMSES 721<br />

- Mains version<br />

- Tappet program disc with daily program<br />

- Synchronous motor drive<br />

- Normal temperature can be set<br />

- Reduced temperature approx. 5 K lower in<br />

relation to the set <strong>comfort</strong> temperature<br />

- Without selector switch<br />

RAMSES 725<br />

As RAMSES 722, but:<br />

- Reduced temperature can be set<br />

- Central control of reduced temperature as<br />

per time program<br />

Product selection<br />

Type of contact<br />

Setting range<br />

temperature<br />

Power<br />

reserve<br />

Type of connection Program Operating<br />

voltage<br />

Type<br />

Article<br />

number<br />

Changeover contact +10 °C … +30 °C <strong>–</strong> 2/3-way conductors Daily/weekly program 2 AA batteries RAMSES 784 7840030<br />

Radio controlled Daily/weekly program 2 AA batteries RAMSES 784 HF Set 1 7849407<br />

3-/4-conductors Daily/weekly program 230 V AC RAMSES 722 7220030<br />

3 days 3-/4-conductors Daily/weekly program 230 V AC RAMSES 782 7820030<br />

<strong>–</strong> 3-/4-conductors Daily program 230 V AC RAMSES 721 7210030<br />

Daily/weekly program 230 V AC RAMSES 725 7250030<br />

162<br />

Additional technical data at: www.theben.de/product/ Article number