Theben Catalogue 2014/15. Save energy – Increase comfort.
Climate control Clock thermostats, OpenTherm Description RAMSES 816 top2 OT - Digital mixer control - 3 different weekly programs - 3 comfort and 2 reduced temperatures can be allocated to each zone - INFO button for the most important data - Party/ECO program - Chimney sweeping function with push button OT box - Minimum boiler temperature can be set - 2-stage burner control option - Holiday program with reduced temperature or date-controlled heating phase can be programmed e. g. for holiday homes - USB interface for modem - Automatic summer/winter time adjustment - Control of feed temperature via motorcontrolled mixer - 3-point controller with feed sensor - Pump protection function - Inputs: feed sensor heating circuit (contained in set), external sensor - Elapsed-time counter for recording relay switching times e.g. burner operating time - Adjustable reminder function for heater maintenance Product selection Type of connection Program Switching capacity at 250 V AC Setting range temperature Operating voltage Type Article number 2-way conductor (BUS) room controller Weekly program 2 x 2 (1), 1 x 1 (1) A +6 °C … +30 °C 230 V AC RAMSES 816 top2 OT 8169132 Technical data RAMSES 816 top2 OT Operating voltage 230 V AC Program Weekly program Frequency 50 Hz Number of memory locations 42 Type of contact NO contact Switching hysteresis 2–20 K 9 Switching capacity 2 x 2 (1) A Relay, 1 x 1 (1) A Relay Setting range temperature +6 °C … +30 °C Mixer runtime Power reserve 2–10 min 4 hours Flow temperature limit +40 °C … +90 °C Stand-by consumption 1,1 W Type of connection 2-way conductor (BUS) room controller Type of protection IP 20 Protection class II according to EN 60 730-1 Accessories Outside temperature sensor RAMSES ↪ Art.No.: 9070463 Details page 254 Room temperature sensor RAMSES IP 65 ↪ Art.No.: 9070459 Details page 254 Plunge sensor RAMSES ↪ Art.No.: 9070379 Details page 255 154 Additional technical data at: www.theben.de/product/ Article number
Climate control Clock thermostats, OpenTherm Scale drawings 250,2 207,7 65.6 Connection diagrams warm à Mixing valve M+ Radiator Boiler-Temp Pump Radiator cold ß Mixing valve M– Pump Flow-Temp Outside temperature Burner Stage 1 Stage 2 M+ M– Floor heating Outside temperature Boiler 9 Additional technical data at: www.theben.de/product/ Article number 155
- Page 105 and 106: Presence and motion detectors Prese
- Page 107 and 108: Presence and motion detectors Prese
- Page 109 and 110: Presence and motion detectors Prese
- Page 111 and 112: Presence and motion detectors Prese
- Page 113 and 114: Presence and motion detectors Prese
- Page 115 and 116: Presence and motion detectors Prese
- Page 117 and 118: Presence and motion detectors Prese
- Page 119 and 120: Presence and motion detectors Prese
- Page 121 and 122: Presence and motion detectors Prese
- Page 123 and 124: Presence and motion detectors Prese
- Page 125 and 126: Presence and motion detectors Motio
- Page 127 and 128: Presence and motion detectors Motio
- Page 129 and 130: Presence and motion detectors Motio
- Page 131 and 132: Presence and motion detectors Motio
- Page 133 and 134: Presence and motion detectors Spotl
- Page 135 and 136: Presence and motion detectors Spotl
- Page 137 and 138: Presence and motion detectors Spotl
- Page 139 and 140: Presence and motion detectors Spotl
- Page 141 and 142: Presence and motion detectors Motio
- Page 143 and 144: Presence and motion detectors Motio
- Page 145 and 146: P T P T Presence and motion detecto
- Page 147 and 148: Climate control Clock thermostats C
- Page 149 and 150: Climate control Clock thermostats,
- Page 151 and 152: Climate control Clock thermostats,
- Page 153 and 154: Climate control Clock thermostats,
- Page 155: Climate control Clock thermostats,
- Page 159 and 160: Climate control Clock thermostats,
- Page 161 and 162: Climate control Clock thermostats,
- Page 163 and 164: Climate control Clock thermostats,
- Page 165 and 166: Climate control Clock thermostats,
- Page 167 and 168: Climate control Room thermostats Ro
- Page 169 and 170: Climate control Room thermostats, M
- Page 171 and 172: Climate control Room thermostats, M
- Page 173 and 174: Climate control Room thermostats, E
- Page 175 and 176: Climate control Sensor technology S
- Page 177 and 178: Climate control Hygrostat Descripti
- Page 179 and 180: Home and building control KNX KNX D
- Page 181 and 182: Home and building control KNX, Swit
- Page 183 and 184: Home and building control KNX, Swit
- Page 185 and 186: Home and building control KNX, 1-10
- Page 187 and 188: Home and building control KNX, Dimm
- Page 189 and 190: Home and building control KNX, Dimm
- Page 191 and 192: Home and building control KNX, Blin
- Page 193 and 194: Home and building control KNX, HVAC
- Page 195 and 196: Home and building control KNX, HVAC
- Page 197 and 198: Home and building control KNX, HVAC
- Page 199 and 200: Home and building control KNX, HVAC
- Page 201 and 202: Home and building control KNX, HVAC
- Page 203 and 204: Home and building control KNX, Moti
- Page 205 and 206: Home and building control KNX, Pres
Climate control<br />
Clock thermostats, OpenTherm<br />
Description<br />
RAMSES 816 top2 OT<br />
- Digital mixer control<br />
- 3 different weekly programs<br />
- 3 <strong>comfort</strong> and 2 reduced temperatures can<br />
be allocated to each zone<br />
- INFO button for the most important data<br />
- Party/ECO program<br />
- Chimney sweeping function with push button<br />
OT box<br />
- Minimum boiler temperature can be set<br />
- 2-stage burner control option<br />
- Holiday program with reduced temperature<br />
or date-controlled heating phase can be<br />
programmed e. g. for holiday homes<br />
- USB interface for modem<br />
- Automatic summer/winter time adjustment<br />
- Control of feed temperature via motorcontrolled<br />
mixer<br />
- 3-point controller with feed sensor<br />
- Pump protection function<br />
- Inputs: feed sensor heating circuit<br />
(contained in set), external sensor<br />
- Elapsed-time counter for recording relay<br />
switching times e.g. burner operating time<br />
- Adjustable reminder function for heater<br />
maintenance<br />
Product selection<br />
Type of connection Program Switching capacity<br />
at 250 V AC<br />
Setting range<br />
temperature<br />
Operating<br />
voltage<br />
Type<br />
Article<br />
number<br />
2-way conductor (BUS)<br />
room controller<br />
Weekly program 2 x 2 (1), 1 x 1 (1) A +6 °C … +30 °C 230 V AC RAMSES 816 top2 OT 8169132<br />
Technical data<br />
RAMSES 816 top2 OT<br />
Operating voltage<br />
230 V AC<br />
Program<br />
Weekly program<br />
Frequency<br />
50 Hz<br />
Number of memory locations 42<br />
Type of contact<br />
NO contact<br />
Switching hysteresis<br />
2<strong>–</strong>20 K<br />
9<br />
Switching capacity<br />
2 x 2 (1) A Relay, 1 x 1 (1) A Relay<br />
Setting range temperature +6 °C … +30 °C<br />
Mixer runtime<br />
Power reserve<br />
2<strong>–</strong>10 min<br />
4 hours<br />
Flow temperature limit +40 °C … +90 °C<br />
Stand-by consumption<br />
1,1 W<br />
Type of connection<br />
2-way conductor (BUS)<br />
room controller<br />
Type of protection IP 20<br />
Protection class II according to EN 60 730-1<br />
Accessories<br />
Outside temperature sensor RAMSES<br />
↪ Art.No.: 9070463<br />
Details page 254<br />
Room temperature sensor RAMSES IP 65<br />
↪ Art.No.: 9070459<br />
Details page 254<br />
Plunge sensor RAMSES<br />
↪ Art.No.: 9070379<br />
Details page 255<br />
154<br />
Additional technical data at: www.theben.de/product/ Article number