Theben Catalogue 2014/15. Save energy – Increase comfort.

28.04.2014 Views

Presence and motion detectors Motion detectors, Outdoor Description SPHINX 105-110 - Motion detector (PIR) - Wall and ceiling installation - Automatic lighting control based on presence and brightness - Sensor head can be adjusted horizontally by ± 90°, vertically by 90° upwards and 25° downwards - Additional creep under protection - Detection area can be limited using enclosed segments - Mixed light measurement suitable for the control of fl uorescent, incandescent and halogen lamps - Zero-cross switching for relay-saving switching and high lamp loads - Instant start-up possible via factory preset - A cover plate protects controls against manipulation - Single-handed plug-in installation with captive screws - RC 105 Pro, service remote control (optional) - RC 105, user remote control (optional) - Adjustable brightness switching value and switch-off delay - Zero-cross swithcing for relay-saving switching and high lamp loads - Teach-in of current brightness value possible via remote control - Pulsee function can be combined with staircase time switches (ELPA) - Test function for checking detection area SPHINX 105-110 - 110° detection angle - Especially suitable for narrow courtyard entrances, house entrances or paths - Internal corner installation with optional corner installation bracket SPHINX 105-220 - 220° detection angle - Particularly suitable for sides of properties, entrances and drives SPHINX 105-300 - 300° detection angle - Corner installation bracket for internal or external corners included in delivery - Especially suitable for external corner installation for simultaneous coverage of two facades via corner 8 Product selection Installation type Channel Detection angle Colour Type Article number Wall and ceiling installation Light 110° White SPHINX 105-110 1050110 220° White SPHINX 105-220 1050220 300° White SPHINX 105-300 1050300 Technical data SPHINX 105-110 SPHINX 105-220 SPHINX 105-300 Operating voltage Frequency Stand-by consumption Setting range brightness 230 V AC 5060 Hz 0.9 W 22000 lx Switching capacity light 16 A (at 230 V AC, cos φ = 1), 10 A (at 230 V AC, cos φ = 0.6), 8 AX (at 230 V AC, cos φ = 0.3) Detection angle 110° 220° 300° Light switch-off delay Incandescent lamp load Fluorescent lamp load (conventional) not corrected Fluorescent lamp load (conventional) parallel-corrected Fluorescent lamp load (conventional) series-corrected Fluorescent lamp load (conventional) lead-lag circuit Energy saving lamps 1 s20 min 2300 W 900 VA 400 VA, 42 μF 900 VA 900 VA 9 x 7 W, 7 x 11 W, 7 x 15 W, 7 x 20 W, 7 x 23 W Ambient temperature 25 °C … +55 °C Protection class II Type of protection IP 55 128 Additional technical data at: www.theben.de/product/ Article number

Presence and motion detectors Motion detectors, Outdoor Detection range (Semicircular) 2,5 m 5 m 15 m 1,25 m 2,5 m 7,5 m SPHINX 105-110 SPHINX 105-220 5 m 10 m 30 m SPHINX 105-300 ■ Walking diagonally to the detector ■ Walking head on to the detector ■ Creep under detection Mounting height 2.5 m Accessories SPHINX RC 105 ↪ Art.No.: 9070539 Details page 252 SPHINX RC 105 Pro ↪ Art.No.: 9070537 Details page 252 RC filter ↪ Art.No.: 9070523 Details page 251 SPHINX corner angle ↪ Art.No.: 9070535 Details page 251 Scale drawings 90 55 30 Connection diagrams 8 N N L L L‘ 159 89 N L Additional technical data at: www.theben.de/product/ Article number 129

Presence and motion detectors<br />

Motion detectors, Outdoor<br />

Description<br />

SPHINX 105-110<br />

- Motion detector (PIR)<br />

- Wall and ceiling installation<br />

- Automatic lighting control based on presence<br />

and brightness<br />

- Sensor head can be adjusted horizontally<br />

by ± 90°, vertically by 90° upwards and 25°<br />

downwards<br />

- Additional creep under protection<br />

- Detection area can be limited using enclosed<br />

segments<br />

- Mixed light measurement suitable for the<br />

control of fl uorescent, incandescent and<br />

halogen lamps<br />

- Zero-cross switching for relay-saving<br />

switching and high lamp loads<br />

- Instant start-up possible via factory preset<br />

- A cover plate protects controls against<br />

manipulation<br />

- Single-handed plug-in installation with<br />

captive screws<br />

- RC 105 Pro, service remote control (optional)<br />

- RC 105, user remote control (optional)<br />

- Adjustable brightness switching value and<br />

switch-off delay<br />

- Zero-cross swithcing for relay-saving<br />

switching and high lamp loads<br />

- Teach-in of current brightness value possible<br />

via remote control<br />

- Pulsee function can be combined with<br />

staircase time switches (ELPA)<br />

- Test function for checking detection area<br />

SPHINX 105-110<br />

- 110° detection angle<br />

- Especially suitable for narrow courtyard<br />

entrances, house entrances or paths<br />

- Internal corner installation with optional<br />

corner installation bracket<br />

SPHINX 105-220<br />

- 220° detection angle<br />

- Particularly suitable for sides of properties,<br />

entrances and drives<br />

SPHINX 105-300<br />

- 300° detection angle<br />

- Corner installation bracket for internal or<br />

external corners included in delivery<br />

- Especially suitable for external corner<br />

installation for simultaneous coverage of two<br />

facades via corner<br />

8<br />

Product selection<br />

Installation type Channel Detection angle Colour Type Article<br />

number<br />

Wall and ceiling installation Light 110° White SPHINX 105-110 1050110<br />

220° White SPHINX 105-220 1050220<br />

300° White SPHINX 105-300 1050300<br />

Technical data<br />

SPHINX 105-110 SPHINX 105-220 SPHINX 105-300<br />

Operating voltage<br />

Frequency<br />

Stand-by consumption<br />

Setting range brightness<br />

230 V AC<br />

50<strong>–</strong>60 Hz<br />

0.9 W<br />

2<strong>–</strong>2000 lx<br />

Switching capacity light 16 A (at 230 V AC, cos φ = 1), 10 A (at 230 V AC, cos φ = 0.6), 8 AX (at 230 V AC, cos φ = 0.3)<br />

Detection angle 110° 220° 300°<br />

Light switch-off delay<br />

Incandescent lamp load<br />

Fluorescent lamp load (conventional) not corrected<br />

Fluorescent lamp load (conventional) parallel-corrected<br />

Fluorescent lamp load (conventional) series-corrected<br />

Fluorescent lamp load (conventional) lead-lag circuit<br />

Energy saving lamps<br />

1 s<strong>–</strong>20 min<br />

2300 W<br />

900 VA<br />

400 VA, 42 μF<br />

900 VA<br />

900 VA<br />

9 x 7 W, 7 x 11 W, 7 x 15 W, 7 x 20 W, 7 x 23 W<br />

Ambient temperature <strong>–</strong>25 °C … +55 °C<br />

Protection class<br />

II<br />

Type of protection IP 55<br />

128<br />

Additional technical data at: www.theben.de/product/ Article number