Theben Catalogue 2014/15. Save energy – Increase comfort.
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Presence and motion detectors<br />
Motion detectors, Outdoor<br />
theLuxa S150 WH<br />
theLuxa S180 BK<br />
Description<br />
Common functions<br />
- Motion detector (PIR)<br />
- Automatic lighting control based on<br />
presence and brightness<br />
- For outdoor use<br />
- Additional creep under protection<br />
- Sensor head can be turned by ± 90°<br />
horizontally and by 30° downwards<br />
- Adjustable brightness switching value and<br />
switch-off delay<br />
- Mixed light measurement suitable for the<br />
control of fl uorescent, incandescent, halogen<br />
lamps and LEDs<br />
- Zero-cross switching for relay-saving<br />
switching and high lamp loads<br />
- Teach-in of current brightness value possible<br />
- Pulsee function<br />
- Test function for checking detection area<br />
- Installation on flush-mounted socket possible<br />
(60 mm)<br />
- Single-handed plug-in installation<br />
- Instant start-up possible via factory preset<br />
- Controls are place protected<br />
- Terminal for protective earth conductor<br />
theLuxa S150<br />
- Detection angle 150°<br />
theLuxa S180<br />
- Detection angle 180°<br />
8<br />
Product selection<br />
Installation type Channel Detection angle Colour Type Article<br />
number<br />
Wall installation Light 150° White theLuxa S150 WH 1010500<br />
Black theLuxa S150 BK 1010501<br />
180° White theLuxa S180 WH 1010505<br />
Black theLuxa S180 BK 1010506<br />
Technical data<br />
theLuxa S150<br />
theLuxa S180<br />
Operating voltage<br />
Frequency<br />
Stand-by consumption<br />
Setting range brightness<br />
230 V AC<br />
50 Hz<br />
0.9 W<br />
5<strong>–</strong>1000 lx<br />
Switching capacity light 10 A (at 230 V AC, cos φ = 1), 6 A (at 230 V AC, cos φ = 0.6), 3 AX (at 230 V AC, cos φ = 0.3)<br />
Detection angle 150° 180°<br />
Light switch-off delay<br />
Incandescent lamp load<br />
Fluorescent lamps electronic ballast<br />
Fluorescent lamp load (conventional) not corrected<br />
Fluorescent lamp load (conventional) parallel-corrected<br />
Fluorescent lamp load (conventional) series-corrected<br />
Energy saving lamps<br />
1 s<strong>–</strong>20 min<br />
2300 W<br />
600 W<br />
400 VA<br />
400 VA, 42 μF<br />
400 VA<br />
150 W<br />
124<br />
Additional technical data at: www.theben.de/product/ Article number