Chapter 3: Installing the VCode<br />

VCode <strong>User</strong> <strong>Guide</strong><br />

Connecting the air tubing: Europe<br />

Introduction<br />

This topic is for customers in Europe only. It explains how to connect the<br />

air tubing to the VCode.<br />

To make the VCode compatible with your lab’s air system, you will need<br />

to connect the VCode’s 1/4-inch air port to the supplied 6-mm air tubing.<br />

This topic describes how to make this connection.<br />

Warnings<br />

!! INJURY HAZARD !! Switch off the air supply before installing<br />

your VCode. When air is flowing you can be injured if the air tubing<br />

whips around and strikes you. If you have not been trained in the<br />

correct way to handle air tubing, contact your facilities department<br />

or the Velocity11 Service Center.<br />

!! DAMAGE HAZARD !! Make sure that the air coming into your<br />

VCode is dry and free of impurities, such as oil, which can shorten<br />

the VCode’s life. If you have any questions about air quality, contact<br />

Velocity11.<br />

Before you start<br />

Before you start, locate the Metric Fittings Kit that is packaged with the<br />

VCode’s Utility Kit.<br />

Connection<br />

assembly<br />

The Metric Fittings Kit contains an adapter. The following diagram shows<br />

how the adapter is connected to your VCode.<br />

Procedure<br />

The following procedure is used to set up a direct connection. If you<br />

have another instrument connected to the house air supply, you can use<br />

the supplied T-connector to connect into the existing air tubing.<br />

To connect the metric fittings adapter:<br />

1. Push one end of the nipple (white plastic tube) into the 1/4-inch<br />

side (red side) of the adapter.<br />

2. Push the other end of the nipple into the VCode’s air input port.<br />

3. Push the 6-mm tubing into the blue side of the adapter.<br />

!! DAMAGE HAZARD !! If you try to insert tubing that has a<br />

different diameter, you could damage the adapter.<br />

4. Gently pull on the air tubing to make sure that the assembly is<br />