Article Designation Colour Packed Article No. Code No. R<br />
Easywave series flush-mounting receiver, 2 channels<br />
2 separate relay contacts, changeover contact, 1 462 FU-E 378013 3<br />
push to make switch µ 10 A, break contact µ 4 A, 230 V, 50 Hz,<br />
independently programmable, can also be used as<br />
roller shutter module for a roller shutter motor 230 V, 50 Hz,<br />
to be used with all Easywave transmitters, per output one LED and<br />
one control pushbutton with ON-OFF function or 1-5,<br />
rotary switch for function selection and time setting.<br />
Up to 32 transmitters can be assigned to one receiver,<br />
16 transmitters per channel. Each transmitter button can be given<br />
a different receiver function. Aerial 460 ANT is recommended.<br />
Selectable functions:<br />
• ON/OFF with 2-pushbutton operation (e.g. lower<br />
transmitter pushbutton = ON, upper pushbutton = OFF)<br />
• ON/OFF with 1-pushbutton operation of the transmitter<br />
• Only ON with selectable operating time of the transmitter<br />
pushbutton, operating time 0–1.5 sec. or 3 sec.<br />
• Only OFF with selectable operating time of the transmitter<br />
pushbutton, operating time 0–1.5 sec. or 3 sec.<br />
• Sequential pushbutton selector max. 10 sec.<br />
• 0.5–120 min time selectable for stairwell function<br />
• Roller shutter function 1-5, selectable running time:<br />
sequential pushbutton selector, 0.4 sec. impulse, 15 sec.,<br />
30 sec., 90 sec., 150 sec.<br />
• Fan control, e.g. output 1 = speed 1, output 2 = speed 2<br />
Technical data:<br />
<strong>Supply</strong> voltage 230 V, 50 Hz, neutral conductor necessary,<br />
for mounting on DIN rail, width 72 mm, 4 module widths,<br />
protection class IP 20, screw terminals, both changeover contacts<br />
suitable for single-phase supply.<br />
Switching capacities (push to make switch):<br />
Filament lamps 230 V<br />
2300 W<br />
High voltage halogen lamps 230 V 1500 W<br />
Transformers and inductive loads 600 VA<br />
Motor load<br />
920 VA<br />
Inrush current<br />
max 80 A/20 ms<br />
Electronic ballasts approx. 4 electronic ballasts directly switchable<br />
(dependent on model).<br />
Note electronic ballast peak inrush current.<br />
When switching more a power relay must be used.<br />
Easywave surface-mounting receiver, 2 channels<br />
2 separate relay contacts, changeover contact, grey 1 462 FU-E WA 378313 3<br />
push to make switch µ 10 A, break contact µ 4 A, 230 V, 50 Hz,<br />
independently programmable, can also be used as<br />
roller shutter module for a roller shutter motor 230 V, 50 Hz,<br />
to be used with all Easywave transmitters.<br />
Functions and switching capacities identical to series flush-mounting<br />
receiver 2 channels article no. 462 FU-E but without LED,<br />
without locally-operated control buttons, external inputs for<br />
2 separate pushbutton switches, programmable pushbutton functions.<br />
Technical data:<br />
<strong>Supply</strong> voltage 230 V, 50 Hz, neutral conductor necessary,<br />
screw terminals, both changeover contacts suitable for single-phase<br />
supply, protection class IP 66, with corresponding M-fixings.<br />
Cable entries: Lengthwise 5 M 16/M 20 cut-outs per side from<br />
top to bottom 2 M 16/M 20 cut-outs per side<br />
with 2 M 20 threaded bushes<br />
Dimensions: L 180 x W 94 x H 66 mm<br />
Easywave, 1–10 V dimmer controller, series flush-mounting,<br />
2 channels<br />
2 outputs for dimming electronic ballasts with 1–10 V DC control 1 463 FU-E 378113 3<br />
input. The outputs are independently programmable. Per output one<br />
LED and one locally-operated control button with ON-OFF function,<br />
rotary switch for function selection and time setting.<br />
Up to 32 transmitters can be assigned to one receiver,<br />
16 transmitters per channel. Each transmitter button can be given<br />
a different receiver function. Aerial 460 ANT is recommended.<br />
Selectable functions:<br />
1-pushbutton operation: Dimmer ON/OFF without memory,<br />
Stop at min. and max.<br />
1-pushbutton operation: Dimmer ON/OFF with memory,<br />
Stop at min. and max.<br />
2-pushbutton operation: Dimmer ON/OFF with memory,<br />
Stop at min. and max.<br />
4-pushbutton operation: ON with memory, OFF, dim until min.,<br />
dim until max.<br />
One pushbutton for retrieving a programmed lighting effect,<br />
one pushbutton for saving and retrieving a lighting effect.<br />
Technical data:<br />
<strong>Supply</strong> voltage 230 V, 50 Hz, neutral conductor necessary,<br />
for mounting on DIN rail, width 72 mm, 4 module widths,<br />
protection class IP 20, screw terminals,<br />
two outputs 1–10 V DC, each max. I = 45 mA control current,<br />
for each output a separate relay contact, push to make switch µ 4 A,<br />
230 V, 50 Hz, inrush current max. 80 A/20 ms,<br />
electronic ballasts approx. 4 electronic ballasts directly switchable<br />
(dependent on model).<br />
Note electronic ballast peak inrush current.<br />
When switching more a power relay must be used.<br />
Easywave radio<br />