Article Designation Colour Packed Article No. Code No. R<br />

Forward phase controlled dimmer 2 x 420 W<br />

Dimmer module for forward phase controlled, 1 944/2 DM AN 290617 7<br />

for ohmic and inductive loads, 2 x 420 W,<br />

for mounting on DIN rail,<br />

incl. 30 cm connecting cable,<br />

72 mm wide (4 module widths),<br />

with memory function,<br />

minimum load per channel 60 W.<br />

Both outputs may NOT be connected in parallel,<br />

synchronisation of the outputs is possible.<br />

PHC Universal dimmer 1000 W<br />

The PHC Universal dimmer can switch and dim connected 1 949 DM UN 294217 7<br />

consumers based both on the principle of forward phase controlled<br />

and on the principle of reverse phase controlled.<br />

When switching on the dimmer, it automatically uses the<br />

appropriate principle, depending on the connected load.<br />

As a result, it is possible to use e.g. filament lamps, inductive loads<br />

or electronic transformers.<br />

The Universal dimmer can be in stand-alone mode or in<br />

Master-Slave mode as dimmer Master in combination with<br />

up to 31 dimmers (Slave dimmers, 439 UN REG).<br />

No mixed loads may be connected to the power output.<br />

108 mm wide (6 module widths).<br />

Power supply: 230 V AC/50–60 Hz<br />

Bus voltage: nom. 24 V DC (SELV)<br />

21–28 V DC, ripple voltage 5%<br />

Internal consumption: 60 mA<br />

Allowable loads: Resistance load: 1000 W<br />

Filament lamps:<br />

1000 W<br />

High voltage halogen lamps: 1000 W<br />

Electronic transformers: 900 VA<br />

Conventional transformers: 900 VA<br />

Minimum load: 60 W/50 VA<br />

Connections: 2 screw terminals for L; N<br />

1 dimming output<br />

1 output for Slave units<br />

(439 UN REG)<br />

PHC inverse phase controlled dimmer Master 1000 W<br />

Dimmer module for inverse phase controlled Master, 1 949 DM M-AB 290917 7<br />

for ohmic loads and electronic transformers,<br />

with 1000 W dimming output and 2 Slave outputs,<br />

for mounting on DIN rail,<br />

incl. 30 cm connecting cable,<br />

108 mm wide (6 module widths),<br />

with memory function,<br />

minimum load 60 W. Depending on the fuse, up to 4 Slave units<br />

439 SL-AB REG can be connected.<br />

The outputs of the Master and Slave units may be connected<br />

in parallel.<br />

Inverse phase controlled dimmer Slave 1000 W<br />

Dimmer module for inverse phase controlled Slave,<br />

capacity extension for PHC dimmer Master 949 DM M-AB, 1 439 SL-AB REG 298613 3<br />

1000 W dimming output and 1 Slave output,<br />

for mounting on DIN rail,<br />

108 mm wide (6 module widths),<br />

with memory function,<br />

minimum load 60 W. The outputs of the Master and Slave units<br />

may be connected in parallel.<br />

PHC forward phase controlled dimmer Master 1000 W<br />

Dimmer module for forward phase controlled Master, 1 949 DM M-AN 290817 7<br />

for ohmic and inductive loads,<br />

with 1000 W dimming output and 2 Slave outputs,<br />

for mounting on DIN rail,<br />

incl. 30 cm connecting cable,<br />

108 mm wide (6 module widths),<br />

with memory function,<br />

minimum load 60 W. Depending on the fuse, up to 4 Slave units<br />

439 SL-AN REG can be controlled.<br />

The outputs of the Master and Slave may not be connected<br />

in parallel.<br />

Forward phase controlled dimmer Slave 1000 W<br />

Dimmer module for forward phase controlled Slave, 1 439 SL-AN REG 294713 3<br />

capacity extension for PHC dimmer Master 949 DM M-AN,<br />

1000 W dimming output and 1 Slave output,<br />

for mounting on DIN rail,<br />

108 mm wide (6 module widths),<br />

with memory function,<br />

minimum load 60 W. The outputs of the Master and Slave<br />

may not be connected in parallel.<br />

PHC<br />

PHC<br />

31