4 ELECTRICAL CONNECTIONS<br />

<strong>DK32</strong> - DK34 - DK37<br />

4.5 DK37/M8E electrical signal output<br />

Figure 4-5: Electrical connection M8E<br />

1 Terminal connection<br />

2 Auxiliary power 14.8...30VDC<br />

3 Measurement signal 4...20mA<br />

4 External load, HART ® communication<br />

The circuitry for connection to other devices such as digital evaluator units or process control<br />

equipment must be designed with especial care. In some circumstances internal connections in<br />

these devices (e.g. GND with PE, ground loops) may lead to impermissible voltage potentials,<br />

which can compromise the function of the device itself or a connected device. In such cases a<br />

protected extra-low voltage (PELV) is recommended.<br />

Figure 4-6: Electrical connection with galvanic isolation<br />

1 Terminal connection<br />

2 Converter supply isolator with galvanic isolation<br />

3 Auxiliary power (see supply isolator information)<br />

4 Measurement signal 4...20mA<br />

5 External load, HART ® communication<br />