<strong>DK32</strong> - DK34 - DK37 H<strong>and</strong>book<br />
<strong>Variable</strong> area flowmeter<br />
© KROHNE 01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en
: IMPRINT :::::::::::::::::::::::::::::::::::::::<br />
All rights reserved. It is prohibited to reproduce this documentation, or any part thereof, without<br />
the prior written authorisation of KROHNE Messtechnik GmbH.<br />
Subject to change without notice.<br />
Copyright 2012 by<br />
KROHNE Messtechnik GmbH - Ludwig-<strong>Krohne</strong>-Str. 5 - 47058 Duisburg (Germany)<br />
2 www.krohne.com 01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en
<strong>DK32</strong> - DK34 - DK37<br />
CONTENTS<br />
1 Safety instructions 5<br />
1.1 Intended use ..................................................................................................................... 5<br />
1.2 Certifications .................................................................................................................... 5<br />
1.3 Safety instructions from the manufacturer ..................................................................... 6<br />
1.3.1 Copyright <strong>and</strong> data protection ................................................................................................ 6<br />
1.3.2 Disclaimer ............................................................................................................................... 6<br />
1.3.3 Product liability <strong>and</strong> warranty ................................................................................................ 7<br />
1.3.4 Information concerning the documentation........................................................................... 7<br />
1.3.5 Warnings <strong>and</strong> symbols used................................................................................................... 8<br />
1.4 Safety instructions for the operator................................................................................. 8<br />
2 Device description 9<br />
2.1 Scope of supply................................................................................................................. 9<br />
2.2 Device versions............................................................................................................... 10<br />
2.3 Nameplate ...................................................................................................................... 11<br />
2.4 Description code............................................................................................................. 12<br />
3 Installation 13<br />
3.1 Notes on installation ......................................................................................................13<br />
3.2 Storage ........................................................................................................................... 13<br />
3.3 Installation requirements .............................................................................................. 13<br />
4 Electrical connections 14<br />
4.1 Safety instructions.......................................................................................................... 14<br />
4.2 Electrical connection of limit switches .......................................................................... 15<br />
4.3 Setting the limit switch...................................................................................................16<br />
4.4 DK37/M8M limit switches............................................................................................... 17<br />
4.5 DK37/M8E electrical signal output ................................................................................ 18<br />
4.5.1 Power supply......................................................................................................................... 19<br />
4.5.2 Load for HART ® communication .......................................................................................... 19<br />
4.5.3 Parametrization .................................................................................................................... 19<br />
4.6 Ground connections........................................................................................................ 20<br />
4.7 Protection category ........................................................................................................21<br />
5 Start-up 22<br />
5.1 St<strong>and</strong>ard device .............................................................................................................. 22<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en<br />
www.krohne.com<br />
3
CONTENTS<br />
<strong>DK32</strong> - DK34 - DK37<br />
6 Service 23<br />
6.1 Maintenance ................................................................................................................... 23<br />
6.2 Spare parts availability...................................................................................................24<br />
6.3 Availability of services .................................................................................................... 24<br />
6.4 Returning the device to the manufacturer..................................................................... 24<br />
6.4.1 General information.............................................................................................................. 24<br />
6.4.2 Form (for copying) to accompany a returned device............................................................ 25<br />
6.5 Disposal .......................................................................................................................... 25<br />
7 Technical data 26<br />
7.1 Operating principle......................................................................................................... 26<br />
7.2 Technical data................................................................................................................. 27<br />
7.3 Dimensions..................................................................................................................... 31<br />
7.4 <strong>Flow</strong> table ....................................................................................................................... 34<br />
7.5 Differential pressure regulators.................................................................................... 36<br />
8 Notes 39<br />
4 www.krohne.com 01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en
<strong>DK32</strong> - DK34 - DK37<br />
SAFETY INSTRUCTIONS 1<br />
1.1 Intended use<br />
CAUTION!<br />
Responsibility for the use of the measuring devices with regard to suitability, intended use <strong>and</strong><br />
corrosion resistance of the used materials against the measured fluid lies solely with the<br />
operator.<br />
INFORMATION!<br />
The manufacturer is not liable for any damage resulting from improper use or use for other than<br />
the intended purpose.<br />
The variable area flowmeters manufactured by KROHNE Messtechnik GmbH are suitable for<br />
measuring gases, vapors <strong>and</strong> liquids.<br />
These flowmeters are particularly suitable for measuring:<br />
• Liquids<br />
• Hydrocarbons<br />
• Water<br />
• Chemicals with low corrosiveness<br />
• Saturated steam<br />
• Superheated steam<br />
• Industrial gases<br />
DANGER!<br />
In case of instruments which are used in explosive endangered areas please consider the<br />
supplementary installation <strong>and</strong> operating instructions mentioned in the Ex-manual.<br />
WARNING!<br />
The operator shall bear sole responsibility for the use of the flowmeters with regard to<br />
suitability, intended use <strong>and</strong> corrosion resistance of the materials used to the process product.<br />
The manufacturer shall not be liable for any damage resulting from improper use or use for<br />
other than the intended purpose.<br />
Do not use any abrasive or highly viscous process products.<br />
1.2 Certifications<br />
CE marking<br />
The flowmeter meets the statutory requirements of the following EC directives:<br />
• Pressure Equipment Directive 97/23/EC<br />
• EMC Directive 89/336/EC for instruments with electrical options<br />
• ATEX Directive 94/9/EC for instruments in Ex-areas<br />
And also<br />
• NAMUR Recommendations NE 21 <strong>and</strong> NE 43 (DK37/M8E)<br />
KROHNE Messtechnik GmbH & Co. KG certifies successful testing of the product by applying the<br />
CE mark.<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en<br />
www.krohne.com<br />
5
1 SAFETY INSTRUCTIONS<br />
<strong>DK32</strong> - DK34 - DK37<br />
1.3 Safety instructions from the manufacturer<br />
1.3.1 Copyright <strong>and</strong> data protection<br />
1.3.2 Disclaimer<br />
The contents of this document have been created with great care. Nevertheless, we provide no<br />
guarantee that the contents are correct, complete or up-to-date.<br />
The contents <strong>and</strong> works in this document are subject to copyright. Contributions from third<br />
parties are identified as such. Reproduction, processing, dissemination <strong>and</strong> any type of use<br />
beyond what is permitted under copyright requires written authorisation from the respective<br />
author <strong>and</strong>/or the manufacturer.<br />
The manufacturer tries always to observe the copyrights of others, <strong>and</strong> to draw on works created<br />
in-house or works in the public domain.<br />
The collection of personal data (such as names, street addresses or e-mail addresses) in the<br />
manufacturer's documents is always on a voluntary basis whenever possible. Whenever<br />
feasible, it is always possible to make use of the offerings <strong>and</strong> services without providing any<br />
personal data.<br />
We draw your attention to the fact that data transmission over the Internet (e.g. when<br />
communicating by e-mail) may involve gaps in security. It is not possible to protect such data<br />
completely against access by third parties.<br />
We hereby expressly prohibit the use of the contact data published as part of our duty to publish<br />
an imprint for the purpose of sending us any advertising or informational materials that we have<br />
not expressly requested.<br />
The manufacturer will not be liable for any damage of any kind by using its product, including,<br />
but not limited to direct, indirect or incidental <strong>and</strong> consequential damages.<br />
This disclaimer does not apply in case the manufacturer has acted on purpose or with gross<br />
negligence. In the event any applicable law does not allow such limitations on implied warranties<br />
or the exclusion of limitation of certain damages, you may, if such law applies to you, not be<br />
subject to some or all of the above disclaimer, exclusions or limitations.<br />
Any product purchased from the manufacturer is warranted in accordance with the relevant<br />
product documentation <strong>and</strong> our Terms <strong>and</strong> Conditions of Sale.<br />
The manufacturer reserves the right to alter the content of its documents, including this<br />
disclaimer in any way, at any time, for any reason, without prior notification, <strong>and</strong> will not be liable<br />
in any way for possible consequences of such changes.<br />
6<br />
www.krohne.com<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en
<strong>DK32</strong> - DK34 - DK37<br />
SAFETY INSTRUCTIONS 1<br />
1.3.3 Product liability <strong>and</strong> warranty<br />
The operator shall bear responsibility for the suitability of the device for the specific purpose.<br />
The manufacturer accepts no liability for the consequences of misuse by the operator. Improper<br />
installation <strong>and</strong> operation of the devices (systems) will cause the warranty to be void. The<br />
respective "St<strong>and</strong>ard Terms <strong>and</strong> Conditions" which form the basis for the sales contract shall<br />
also apply.<br />
1.3.4 Information concerning the documentation<br />
To prevent any injury to the user or damage to the device it is essential that you read the<br />
information in this document <strong>and</strong> observe applicable national st<strong>and</strong>ards, safety requirements<br />
<strong>and</strong> accident prevention regulations.<br />
If this document is not in your native language <strong>and</strong> if you have any problems underst<strong>and</strong>ing the<br />
text, we advise you to contact your local office for assistance. The manufacturer can not accept<br />
responsibility for any damage or injury caused by misunderst<strong>and</strong>ing of the information in this<br />
document.<br />
This document is provided to help you establish operating conditions, which will permit safe <strong>and</strong><br />
efficient use of this device. Special considerations <strong>and</strong> precautions are also described in the<br />
document, which appear in the form of underneath icons.<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en<br />
www.krohne.com<br />
7
1 SAFETY INSTRUCTIONS<br />
<strong>DK32</strong> - DK34 - DK37<br />
1.3.5 Warnings <strong>and</strong> symbols used<br />
Safety warnings are indicated by the following symbols.<br />
DANGER!<br />
This information refers to the immediate danger when working with electricity.<br />
DANGER!<br />
This warning refers to the immediate danger of burns caused by heat or hot surfaces.<br />
DANGER!<br />
This warning refers to the immediate danger when using this device in a hazardous atmosphere.<br />
DANGER!<br />
These warnings must be observed without fail. Even partial disregard of this warning can lead to<br />
serious health problems <strong>and</strong> even death. There is also the risk of seriously damaging the device<br />
or parts of the operator's plant.<br />
WARNING!<br />
Disregarding this safety warning, even if only in part, poses the risk of serious health problems.<br />
There is also the risk of damaging the device or parts of the operator's plant.<br />
CAUTION!<br />
Disregarding these instructions can result in damage to the device or to parts of the operator's<br />
plant.<br />
INFORMATION!<br />
These instructions contain important information for the h<strong>and</strong>ling of the device.<br />
LEGAL NOTICE!<br />
This note contains information on statutory directives <strong>and</strong> st<strong>and</strong>ards.<br />
• HANDLING<br />
This symbol designates all instructions for actions to be carried out by the operator in the<br />
specified sequence.<br />
i<br />
RESULT<br />
This symbol refers to all important consequences of the previous actions.<br />
1.4 Safety instructions for the operator<br />
WARNING!<br />
In general, devices from the manufacturer may only be installed, commissioned, operated <strong>and</strong><br />
maintained by properly trained <strong>and</strong> authorized personnel.<br />
This document is provided to help you establish operating conditions, which will permit safe <strong>and</strong><br />
efficient use of this device.<br />
8<br />
www.krohne.com<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en
<strong>DK32</strong> - DK34 - DK37<br />
DEVICE DESCRIPTION 2<br />
2.1 Scope of supply<br />
INFORMATION!<br />
Inspect the cartons carefully for damages or signs of rough h<strong>and</strong>ling. Report damage to the<br />
carrier <strong>and</strong> to the local office of the manufacturer.<br />
INFORMATION!<br />
Do a check of the packing list to make sure that you have all the elements given in the order.<br />
INFORMATION!<br />
Look at the device nameplate to ensure that the device is delivered according to your order.<br />
Check for the correct supply voltage printed on the nameplate.<br />
Figure 2-1: Scope of supply<br />
1 <strong>Flow</strong>meter in the version ordered<br />
2 Manual<br />
3 Certificates, calibration certificate (supplied to order only)<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en<br />
www.krohne.com<br />
9
2 DEVICE DESCRIPTION<br />
<strong>DK32</strong> - DK34 - DK37<br />
2.2 Device versions<br />
• <strong>DK32</strong> with valve <strong>and</strong> horizontal connection<br />
• DK34 without valve <strong>and</strong> vertical connection<br />
• DK37 with valve <strong>and</strong> horizontal connection<br />
The following designs are available as options:<br />
• with inlet pressure regulator<br />
• with outlet pressure regulator<br />
Device versions<br />
1 <strong>DK32</strong> with valve - with horizontal connection<br />
2 DK34 without valve - with vertical connection<br />
3 DK37/M8E with valve <strong>and</strong> electronic display<br />
4 DK37/M8M with valve <strong>and</strong> mechanical display<br />
Versions with regulator<br />
1 <strong>DK32</strong> with inlet pressure regulator<br />
2 DK37 with inlet pressure regulator<br />
10<br />
www.krohne.com<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en
<strong>DK32</strong> - DK34 - DK37<br />
DEVICE DESCRIPTION 2<br />
2.3 Nameplate<br />
INFORMATION!<br />
Before installing the flowmeter, make sure that the information given on the nameplate<br />
corresponds to the ordering data.<br />
Figure 2-2: Nameplates<br />
1 Type of meter<br />
2 Manufacturer<br />
3 Appointed ATEX & DGRL body<br />
4 Design data: temperature & pressure rating<br />
5 DGRL data<br />
6 Ex data<br />
7 Electrical connection data<br />
8 Pay regard to manual<br />
9 KROHNE website<br />
Additional markings on the flowmeter:<br />
• SO - sales order / item<br />
• PA - order<br />
• Vx - product configurator code<br />
• AC - article code<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en<br />
www.krohne.com<br />
11
2 DEVICE DESCRIPTION<br />
<strong>DK32</strong> - DK34 - DK37<br />
2.4 Description code<br />
Description code <strong>DK32</strong> DK34<br />
The description code consists of the following elements*:<br />
1 32 - with valve <strong>and</strong> horizontal connection / 34 without valve <strong>and</strong> vertical connection<br />
2 RE - inlet pressure regulator / RA - outlet pressure regulator<br />
3 K1 - one limit switch / K2 - two limit switches<br />
4 S - plug connector / L - cable gl<strong>and</strong> incl. cable<br />
5 HT - high-temperature version<br />
6 A - limit switch EC type-tested<br />
7 EX - Explosion-protected equipment<br />
8 SK - SIL2 compliance of limit switches acc. to IEC 61508<br />
* positions which are not needed are omitted (no blank positions)<br />
Description code DK37<br />
The description code* consists of the following elements:<br />
1 M8M - Mechanical display / M8E - Electronic display <strong>and</strong> signal output 4...20mA<br />
2 RE - Inlet pressure regulator / RA - Outlet pressure regulator<br />
3 K1 - one limit switch / K2 - two limit switches<br />
4 Ex is not part of the designation key<br />
5 SK - SIL2 compliance of limit switches acc. to IEC 61508<br />
SE - SIL1 compliance of current output acc. to IEC 61508<br />
* positions which are not needed are omitted (no blank positions)<br />
12<br />
www.krohne.com<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en
<strong>DK32</strong> - DK34 - DK37<br />
INSTALLATION 3<br />
3.1 Notes on installation<br />
INFORMATION!<br />
Inspect the cartons carefully for damages or signs of rough h<strong>and</strong>ling. Report damage to the<br />
carrier <strong>and</strong> to the local office of the manufacturer.<br />
INFORMATION!<br />
Do a check of the packing list to make sure that you have all the elements given in the order.<br />
INFORMATION!<br />
Look at the device nameplate to ensure that the device is delivered according to your order.<br />
Check for the correct supply voltage printed on the nameplate.<br />
3.2 Storage<br />
• Store the flowmeter in a dry <strong>and</strong> dust-free location.<br />
• Avoid lasting direct exposure to the sun.<br />
• Store the flowmeter in its original packaging.<br />
• The permissible storage temperature is from -40 to +80°C for st<strong>and</strong>ard meters.<br />
3.3 Installation requirements<br />
CAUTION!<br />
When installing the flowmeter in the piping please observe the following points:<br />
• The variable area flowmeter must be installed vertically (measuring principle). The flow<br />
direction must be from bottom to top. For installation recommendations please refer also to<br />
VDI/VDE Directive 3513 Sheet 3.<br />
• Before connecting, blow or flush out the pipes leading to the flowmeter.<br />
• Pipes for gas flow need to be dried before the flowmeter is installed.<br />
• Use connectors suitable for the particular version of the flowmeter.<br />
• Align the pipes axially with the connections on the flowmeter so that they are free of stresses.<br />
• If necessary, the piping has to be supported to prevent vibrations being transmitted to the<br />
flowmeter.<br />
• Do not lay signal cables directly next to cables for the power supply.<br />
• If several instruments are installed side by side, a minimum distance between these divices is<br />
required (see Technical Data).<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en<br />
www.krohne.com<br />
13
4 ELECTRICAL CONNECTIONS<br />
<strong>DK32</strong> - DK34 - DK37<br />
4.1 Safety instructions<br />
DANGER!<br />
All work on the electrical connections may only be carried out with the power disconnected. Take<br />
note of the voltage data on the nameplate!<br />
DANGER!<br />
Observe the national regulations for electrical installations!<br />
DANGER!<br />
For devices used in hazardous areas, additional safety notes apply; please refer to the Ex<br />
documentation.<br />
WARNING!<br />
Observe without fail the local occupational health <strong>and</strong> safety regulations. Any work done on the<br />
electrical components of the measuring device may only be carried out by properly trained<br />
specialists.<br />
INFORMATION!<br />
Look at the device nameplate to ensure that the device is delivered according to your order.<br />
Check for the correct supply voltage printed on the nameplate.<br />
14<br />
www.krohne.com<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en
<strong>DK32</strong> - DK34 - DK37<br />
ELECTRICAL CONNECTIONS 4<br />
4.2 Electrical connection of limit switches<br />
The electrical connections for limit switches is effected:<br />
• DK../../S - in the plug connector<br />
• DK../../L - using a preassembled cable.<br />
The following procedures must be performed (DK../../S):<br />
• Slacken screw 6 of the connector plug<br />
• Pull out the plug<br />
• Remove screw 6 completely from the plug<br />
• Insert a screwdriver in the marked opening 5 (Lift) <strong>and</strong> remove the terminal block.<br />
• Thread the connecting cable through the cable gl<strong>and</strong>.<br />
• Insert the cable (max. 1.5mm 2 ) <strong>and</strong> screw down.<br />
Figure 4-1: Electrical connection of limit switches<br />
5 - Lift slot<br />
6 - Fastening screw of terminal box<br />
Contact connection<br />
Cable colors of assembled cable<br />
1 Min minus white<br />
2 Min plus yellow<br />
3 Max minus green<br />
4 Max plus brown<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en<br />
www.krohne.com<br />
15
4 ELECTRICAL CONNECTIONS<br />
<strong>DK32</strong> - DK34 - DK37<br />
Connection three-wire reed contact<br />
Figure 4-2: Electrical connection of reed contact limit switch<br />
Str<strong>and</strong> colours for flowmeters with preassembled cables:<br />
1 Silicone-insulated wire - yellow/green / FEP-insulated wire - red<br />
2 Silicone-insulated wire - brown / FEP-insulated wire - brown<br />
3 Silicone-insulated wire - blue / FEP-insulated wire - blue<br />
4.3 Setting the limit switch<br />
Set the pointers to the desired limit values as a min. contact 1 <strong>and</strong> max. contact 2 using a slip<br />
coupling along the scale.<br />
Figure 4-3: Limit switch settings<br />
Adjusting the limit switch with reed contact:<br />
• Slacken nut 3<br />
• Set reed cartridge to the required value<br />
• Secure with nut 3<br />
Comment<br />
The reed contact is actuated directly by the float magnet. The desired operating point can only be<br />
determined in measuring mode. A reference to the scale <strong>and</strong>/or pointer cannot be established.<br />
16<br />
www.krohne.com<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en
<strong>DK32</strong> - DK34 - DK37<br />
ELECTRICAL CONNECTIONS 4<br />
4.4 DK37/M8M limit switches<br />
The limit switches can be set over the entire measuring range using the maximum pointer. The<br />
set limit values are displayed on the scale. The pointers are set to the desired limit values using<br />
a slip coupling along the scale.<br />
Figure 4-4: Limit switch setting<br />
1 Maximum pointer, switching point indicator<br />
2 Limit switch<br />
3 Connection board<br />
4 Connection terminal<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en<br />
www.krohne.com<br />
17
4 ELECTRICAL CONNECTIONS<br />
<strong>DK32</strong> - DK34 - DK37<br />
4.5 DK37/M8E electrical signal output<br />
Figure 4-5: Electrical connection M8E<br />
1 Terminal connection<br />
2 Auxiliary power 14.8...30VDC<br />
3 Measurement signal 4...20mA<br />
4 External load, HART ® communication<br />
The circuitry for connection to other devices such as digital evaluator units or process control<br />
equipment must be designed with especial care. In some circumstances internal connections in<br />
these devices (e.g. GND with PE, ground loops) may lead to impermissible voltage potentials,<br />
which can compromise the function of the device itself or a connected device. In such cases a<br />
protected extra-low voltage (PELV) is recommended.<br />
Figure 4-6: Electrical connection with galvanic isolation<br />
1 Terminal connection<br />
2 Converter supply isolator with galvanic isolation<br />
3 Auxiliary power (see supply isolator information)<br />
4 Measurement signal 4...20mA<br />
5 External load, HART ® communication<br />
18<br />
www.krohne.com<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en
<strong>DK32</strong> - DK34 - DK37<br />
ELECTRICAL CONNECTIONS 4<br />
4.5.1 Power supply<br />
INFORMATION!<br />
The supply voltage has to be between 14.8VDC <strong>and</strong> 30VDC. This is based on the total resistance<br />
of the measuring loop. To determine this, add up the resistances of each component in the<br />
measuring loop (not including the meter).<br />
The required supply voltage can be calculated using the formula below:<br />
U ext. = R L * 22mA + 14.8V<br />
where<br />
U ext. = the minimum supply voltage <strong>and</strong><br />
R L = the total measuring loop resistance.<br />
INFORMATION!<br />
The power supply has to be able to supply a minimum of 22mA.<br />
4.5.2 Load for HART ® communication<br />
INFORMATION!<br />
For HART ® communication a load of at least 230 ohm is required.<br />
The maximum load impedance is calculated as follows:<br />
DANGER!<br />
Use a twisted two-core cable to prevent electrical interference from impeding the DC output<br />
signal.<br />
In some cases a shielded cable may be necessary. The cable shield may only be earthed<br />
(grounded) at one place (on the power supply unit).<br />
4.5.3 Parametrization<br />
The M8E electronic display can be parametrized via HART ® communications. DD (Device<br />
Descriptions) for AMS 6.x <strong>and</strong> PDM 5.2 <strong>and</strong> a DTM (Device Type Manager) are available for<br />
parametrization (download center).<br />
The current flowrate can be transmitted using the integral HART ® communications. A flow<br />
counter can be parametrized. Two limit values can be monitored. The limit values are assigned<br />
either to flow values or to the counter overflow. The limit values are not depicted on the display.<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en<br />
www.krohne.com<br />
19
4 ELECTRICAL CONNECTIONS<br />
<strong>DK32</strong> - DK34 - DK37<br />
4.6 Ground connections<br />
The earthing can be done on the head piece of the measuring section (M4 threaded hole)<br />
Figure 4-7: Ground connections<br />
1 Earth connection on the measuring section<br />
DANGER!<br />
The earth conductor must not transfer any interference voltage.<br />
Do not use this earth conductor to ground any other items of electrical equipment.<br />
20<br />
www.krohne.com<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en
<strong>DK32</strong> - DK34 - DK37<br />
ELECTRICAL CONNECTIONS 4<br />
4.7 Protection category<br />
The variable area flowmeters <strong>DK32</strong> / DK34 / DK37 have been tested for ingress protection<br />
according to EN 60529. The following grades of protection are confirmed:<br />
Ingress Protection<br />
EN 60529<br />
Mechanical version<br />
without cable gl<strong>and</strong>s<br />
Electrical version<br />
with cable gl<strong>and</strong>s<br />
<strong>DK32</strong> / DK34 IP66 / IP68 IP65<br />
DK37 IP66 IP66<br />
DANGER!<br />
After all servicing <strong>and</strong> maintenance work on the flowmeter, the specified protection category has<br />
to be ensured again.<br />
Therefore it is essential to observe the following points:<br />
• Use only original gaskets. They must be clean <strong>and</strong> free of any damage. Defective gaskets have<br />
to be replaced.<br />
• The electrical cables used must be undamaged <strong>and</strong> must comply with regulations.<br />
• The cable has to be laid with a loop 3 upstream of the flowmeter to prevent water from<br />
getting into the housing.<br />
• The cable gl<strong>and</strong>s 2 have to be firmly tightened.<br />
• Close the unused cable gl<strong>and</strong>s using blanking plugs 1.<br />
• Do not remove the specified outer sheath from the cable gl<strong>and</strong>.<br />
Figure 4-8: Cable gl<strong>and</strong><br />
1 Close the unused cable gl<strong>and</strong>s using blanking plugs.<br />
2 The cable gl<strong>and</strong>s have to be firmly tightened.<br />
3 The cable has to be laid with a loop.<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en<br />
www.krohne.com<br />
21
5 START-UP<br />
<strong>DK32</strong> - DK34 - DK37<br />
5.1 St<strong>and</strong>ard device<br />
CAUTION!<br />
When starting up the device, the following points must be observed:<br />
• Compare the actual operating pressure <strong>and</strong> the product temperature of the system with the<br />
specifications on the nameplate (PS <strong>and</strong> TS). These specifications may not be exceeded.<br />
• Make sure materials are compatible.<br />
• Slowly open the shut-off valve.<br />
• When measuring liquids, vent the pipes carefully.<br />
• When measuring gases, increase pressure slowly.<br />
• Avoid float impact (e.g. caused by solenoid valves), as this is likely to damage the measuring<br />
unit or float.<br />
22<br />
www.krohne.com<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en
<strong>DK32</strong> - DK34 - DK37<br />
SERVICE 6<br />
6.1 Maintenance<br />
Within the scope of routine maintenance of the system <strong>and</strong> pipelines, the flowmeter should also<br />
be inspected for signs of fouling, corrosion, mechanical wear <strong>and</strong> leaks, as well as damage to<br />
the measuring tube <strong>and</strong> indicator.<br />
We advise that inspections be carried out at least once a year.<br />
The device must be removed from the piping before cleaning.<br />
CAUTION!<br />
Pressurized pipes must be depressurized before removing the device.<br />
In the case of flowmeters used for measuring aggressive or hazardous products, appropriate<br />
safety precautions must be taken with regard to residual liquids in the measuring section.<br />
Always use new gaskets when reinstalling the flowmeter in the pipeline.<br />
CAUTION!<br />
Under certain circumstances the valve packing gl<strong>and</strong> may have to be adjusted during its service<br />
life. This means that the union nut 1 has to be retightened. If necessary, press the retaining pin<br />
2 against its internal spring.<br />
Apply a tightening torque of not more than 5Nm.<br />
CAUTION!<br />
Valves that have not been actuated for a longer period of time may exhibit a higher initial<br />
actuation torque.<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en<br />
www.krohne.com<br />
23
6 SERVICE<br />
<strong>DK32</strong> - DK34 - DK37<br />
6.2 Spare parts availability<br />
The manufacturer adheres to the basic principle that functionally adequate spare parts for each<br />
device or each important accessory part will be kept available for a period of 3 years after<br />
delivery of the last production run for the device.<br />
This regulation only applies to spare parts which are subject to wear <strong>and</strong> tear under normal<br />
operating conditions.<br />
6.3 Availability of services<br />
The manufacturer offers a range of services to support the customer after expiration of the<br />
warranty. These include repair, maintenance, technical support <strong>and</strong> training.<br />
INFORMATION!<br />
For more precise information, please contact your local representative.<br />
6.4 Returning the device to the manufacturer<br />
6.4.1 General information<br />
This device has been carefully manufactured <strong>and</strong> tested. If installed <strong>and</strong> operated in accordance<br />
with these operating instructions, it will rarely present any problems.<br />
CAUTION!<br />
Should you nevertheless need to return a device for inspection or repair, please pay strict<br />
attention to the following points:<br />
• Due to statutory regulations on environmental protection <strong>and</strong> safeguarding the health <strong>and</strong><br />
safety of our personnel, manufacturer may only h<strong>and</strong>le, test <strong>and</strong> repair returned devices that<br />
have been in contact with products without risk to personnel <strong>and</strong> environment.<br />
• This means that the manufacturer can only service this device if it is accompanied by the<br />
following certificate (see next section) confirming that the device is safe to h<strong>and</strong>le.<br />
CAUTION!<br />
If the device has been operated with toxic, caustic, flammable or water-endangering products,<br />
you are kindly requested:<br />
• to check <strong>and</strong> ensure, if necessary by rinsing or neutralizing, that all cavities are free from<br />
such dangerous substances,<br />
• to enclose a certificate with the device confirming that is safe to h<strong>and</strong>le <strong>and</strong> stating the<br />
product used.<br />
24<br />
www.krohne.com<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en
<strong>DK32</strong> - DK34 - DK37<br />
SERVICE 6<br />
6.4.2 Form (for copying) to accompany a returned device<br />
Company:<br />
Address:<br />
Department:<br />
Name:<br />
Tel. no.:<br />
Fax no.:<br />
Manufacturer's order no. or serial no.:<br />
The device has been operated with the following medium:<br />
This medium is:<br />
water-hazardous<br />
toxic<br />
caustic<br />
flammable<br />
We checked that all cavities in the device are free from such<br />
substances.<br />
We have flushed out <strong>and</strong> neutralized all cavities in the<br />
device.<br />
We hereby confirm that there is no risk to persons or the environment through any residual media<br />
contained in the device when it is returned.<br />
Date:<br />
Signature:<br />
Stamp:<br />
6.5 Disposal<br />
CAUTION!<br />
Disposal must be carried out in accordance with legislation applicable in your country.<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en<br />
www.krohne.com<br />
25
7 TECHNICAL DATA<br />
<strong>DK32</strong> - DK34 - DK37<br />
7.1 Operating principle<br />
The flowmeter operates on the float measuring principle.<br />
The measuring section consists of a metal cone in which a float can move freely up <strong>and</strong> down.<br />
The medium flows through the flowmeter from bottom to top.<br />
The float adjusts itself so that the buoyancy force A acting on it, the form drag W <strong>and</strong> its weight G<br />
are in equilibrium: G = A + W.<br />
Figure 7-1: Operating principle<br />
For the <strong>DK32</strong>, DK34 <strong>and</strong> DK37/M8M 1 the flow-dependent height of the float in the measuring<br />
section is transmitted by means of a magnetic coupling <strong>and</strong> displayed on a scale.<br />
For the DK37/M8E 2 the flow-dependent height of the float in the measuring section is<br />
transmitted to the electronic display by means of a magnetic coupling on sensors S1 <strong>and</strong> S2.<br />
26<br />
www.krohne.com<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en
<strong>DK32</strong> - DK34 - DK37<br />
TECHNICAL DATA 7<br />
7.2 Technical data<br />
INFORMATION!<br />
• The following data is provided for general applications. If you require data that is more<br />
relevant to your specific application, please contact us or your local representative.<br />
• Additional information (certificates, special tools, software,...) <strong>and</strong> complete product<br />
documentation can be downloaded free of charge from the website (Download Center).<br />
Measuring system<br />
Application range<br />
Operating method / measuring principle<br />
Measured value<br />
Primary measured value<br />
Secondary measured value<br />
<strong>Flow</strong> measurement of liquids, gases <strong>and</strong> vapors<br />
Float measuring principle<br />
Float position<br />
Operating <strong>and</strong> st<strong>and</strong>ard volumetric flow<br />
Measuring accuracy<br />
Directive VDI / VDE Code 3513 Sheet 2 (q G =50%)<br />
<strong>DK32</strong> DK34 4.0%<br />
DK37 2.5%<br />
Operating conditions<br />
Max. operating temperature TS<br />
Operating pressure PS<br />
Test pressure PT<br />
-80..+200°C / -112...+392°F<br />
Pressure Equipment Directive 97/23/EC<br />
Pressure Equipment Directive 97/23/EC <strong>and</strong> AD 2000-HP30<br />
Max. allowable operating pressure PS 130 bar st<strong>and</strong>ard 1<br />
Protection category<br />
<strong>DK32</strong> / DK34 without cable gl<strong>and</strong>s<br />
<strong>DK32</strong> / DK34 with cable gl<strong>and</strong>s<br />
DK37<br />
IP66 <strong>and</strong> IP68<br />
IP65<br />
IP66<br />
Installation conditions<br />
Inlet / outlet run<br />
1 higher pressures on request<br />
non<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en<br />
www.krohne.com<br />
27
7 TECHNICAL DATA<br />
<strong>DK32</strong> - DK34 - DK37<br />
Materials<br />
Head piece, foot piece, cone<br />
CrNi steel 1.4404 / 316 L<br />
upper plug<br />
CrNi steel 1.4404 / 316 L<br />
St<strong>and</strong>ard float<br />
CrNi steel 1.4404 / 316 L or titanium<br />
Metering unit<br />
CrNi steel 1.4571 / 316 Ti<br />
Valve spindle<br />
CrNi steel 1.4404 / 316 L<br />
Valve plug gasket FPM 1<br />
Metering unit gasket FPM <strong>and</strong> PTFE 1<br />
Indicator housing <strong>DK32</strong> 34<br />
Die-cast Aluminium, coated<br />
Indicator housing DK37<br />
PPS<br />
1 other gasket materials on request<br />
Temperatures<br />
Max. process temperature at T amb. < 40°C / 104°F [°C]<br />
[°F]<br />
<strong>DK32</strong> with valve -40...+150 1 -40...+302 1<br />
DK34 without valve -80...+150 1 -112...+302 1<br />
<strong>DK32</strong> DK34 with limit switches -25/-40...+145 -13/-40...+293<br />
DK37M8M without valve -80...+150 1 -112...+302 1<br />
DK37M8M with valve -40...+150 1 -40...+302 1<br />
DK37/M8M with limit switches -25/-40...+150 13/-40...+302<br />
DK37M8E with electronical indicator -25...+135 -13...+275<br />
Max. ambient temperature T amb. -25...+70 -13...+158<br />
1 High temperature version up to 200°C / 392°F<br />
28<br />
www.krohne.com<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en
<strong>DK32</strong> - DK34 - DK37<br />
TECHNICAL DATA 7<br />
Indicators of <strong>DK32</strong> DK34 DK37/M8M with limit switches<br />
<strong>DK32</strong> - 34 /K./S<br />
DK37M8M<br />
Cable fitting M16 x 1,5<br />
Clamp terminal 1,5mm 2<br />
<strong>DK32</strong> - 34 /K./S Clamping range 4,5... 10mm<br />
DK37M8M Clamping range 3...7mm<br />
<strong>DK32</strong> - 34/K./L ∅ Connecting cable approx. 7mm<br />
Cable length<br />
approx. 1.7m (other length on request)<br />
Limit switch<br />
SC2-N0 SJ2-SN 1 SJ2-S1N 1<br />
I7S2002-N<br />
Type NAMUR 2-wire 2-wire 2-wire<br />
Switch element function<br />
Normally Normally Normally open<br />
closed closed<br />
Nominal voltage U 0 8VDC 8VDC 8VDC<br />
Pointer shaft not read ≥3mA ≥3mA ≤1mA<br />
Pointer shaft read ≤1mA ≤1mA ≥3mA<br />
<strong>DK32</strong> DK34 with reed contact Switching type bistable<br />
Switching reproducibility
7 TECHNICAL DATA<br />
<strong>DK32</strong> - DK34 - DK37<br />
M8E HART ® parameter configuration<br />
Name of manufacturer (code) KROHNE Messtechnik (69)<br />
Name of model M8E (230)<br />
HART ® protocol revision 5.1<br />
Device revision 1<br />
Physical layer<br />
FSK<br />
Device category<br />
Transmitter<br />
M8E process variable<br />
M8E process variable flow Values [%] Signal output [mA]<br />
Over range +102,5 (±1%) 20,24...20,56<br />
Device error detection >106,25 ≥21,00<br />
Maximum 112,5 22<br />
Multi-drop operation - 4,5<br />
Min. U ext.<br />
14,8VDC<br />
Approvals<br />
St<strong>and</strong>ard Indicator Designation<br />
ATEX <strong>DK32</strong> DK34 mechanical II2GD IIC<br />
II3GD IIC<br />
<strong>DK32</strong> DK34 electrical II2G Ex ia IIC T6<br />
DK37 mechanical II2GD IIC<br />
II3GD IIC<br />
DK37 electrical<br />
II2G Ex ia IIC T6<br />
IEC Ex <strong>DK32</strong> DK34 electrical Ex ia IIC T6<br />
FM <strong>DK32</strong> DK34 IS/I/1/ABCD;T6<br />
NI/I/2/ABCD;T6<br />
S/II, III/2/FG;T6<br />
IS/I, II, III/1/A-G<br />
NI/II/2/ABCD<br />
Nepsi <strong>DK32</strong> DK34 Ex nA II T1-T6<br />
DK37<br />
Ex ia IIC T1-T6<br />
30<br />
www.krohne.com<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en
<strong>DK32</strong> - DK34 - DK37<br />
TECHNICAL DATA 7<br />
7.3 Dimensions<br />
Dimensions, <strong>DK32</strong> DK34<br />
a b c d<br />
Device [mm] ["] [mm] ["] [mm] ["] [mm] ["]<br />
1 <strong>DK32</strong> with valve <strong>and</strong><br />
horizontal process<br />
connections<br />
2 DK34 without valve<br />
<strong>and</strong> vertical process<br />
connections<br />
3 <strong>DK32</strong> DK34 with<br />
limit switches K1/K2<br />
4 <strong>DK32</strong> with flange<br />
connections<br />
42 1,66 118 4,65 90 3,55 100 3,94<br />
42 1,66 110 4,33 - - 75 3,07<br />
46 1,81 approx.<br />
90<br />
ca. 3,55 1500 50,1 approx.<br />
50<br />
- - 250 10,2 90 3,55 approx.<br />
195<br />
ca. 1,97<br />
ca. 7,68<br />
<strong>DK32</strong> <strong>DK32</strong> DK34 DK34<br />
<strong>DK32</strong> (DK34) with K1/K2 <strong>DK32</strong> (DK34) with K1/K2 <strong>DK32</strong> with flange connections<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en<br />
www.krohne.com<br />
31
7 TECHNICAL DATA<br />
<strong>DK32</strong> - DK34 - DK37<br />
DK37 dimensions<br />
a b c d approx.<br />
Device [ mm] ["] [ mm] ["] [ mm] ["] [ mm] ["]<br />
1 DK37/M8E with<br />
valve <strong>and</strong> horizontal<br />
process connections<br />
2 DK37/M8E with<br />
valve on top<br />
3 DK37/M8M/K . with<br />
valve <strong>and</strong> horizontal<br />
process connections<br />
4 DK37/M8M/K .<br />
without valve <strong>and</strong><br />
vertical process<br />
connections<br />
5 DK37/M8E without<br />
valve <strong>and</strong> vertical<br />
process connections<br />
56 2,21 153 6,03 125 4,92 144 ca. 5,67<br />
56 2,21 183 7,21 155 6,11 144 ca. 5,67<br />
56 2,21 153 6,03 125 4,92 160 ca. 6,15<br />
56 2,21 145 5,71 145 5,71 144 ca. 5,52<br />
56 2,21 145 5,71 145 5,71 121 ca. 4,77<br />
DK37/M8M with valve DK37/M8E with valve DK37/M8E with valve on top<br />
DK37/M8M with K1/K2<br />
DK37/M8M without valve <strong>and</strong><br />
vertical connections<br />
DK37/M8E without valve <strong>and</strong><br />
vertical connections<br />
32<br />
www.krohne.com<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en
<strong>DK32</strong> - DK34 - DK37<br />
TECHNICAL DATA 7<br />
Min. installation distance<br />
If several instruments are installed side by side, a minimum distance betwween these<br />
instruments is required.<br />
Min. distance<br />
Device [mm] ["]<br />
1 <strong>DK32</strong> / DK34 60 2,36<br />
2 DK37/M8M 100 3,94<br />
2 DK37/M8E 120 4,73<br />
Weights<br />
Approx. weights [g] ca. [lb]<br />
<strong>DK32</strong> 700 1,54<br />
DK34 600 1,32<br />
DK37/M8M 800 1,76<br />
DK37/M8E 1000 2,21<br />
<strong>DK32</strong> with differential pressure regulators 2500 5,51<br />
DK37/M8E with differential pressure regulators 2800 6,18<br />
DK37/M8M with differential pressure regulators 2600 5,73<br />
Connections<br />
St<strong>and</strong>ard 1/4" NPT inside thread<br />
G 1/4, Ermeto, Serto, Dilo, Gyrolok, Swagelok, flanges 1<br />
1 other connections on request<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en<br />
www.krohne.com<br />
33
7 TECHNICAL DATA<br />
<strong>DK32</strong> - DK34 - DK37<br />
7.4 <strong>Flow</strong> table<br />
Measuring span: 10 : 1<br />
Declaration of flow: Values = 100%<br />
Water: 20°C [68°F]<br />
Air: 20°C [68°F], 1,2 bar abs. [17.4 psia]<br />
Water flow rate Air flow rate Pressure drop<br />
Cones [l/h] [GPH] [Nl/h] [SCFH] [mbar] [psig]<br />
K 005 - - 16 1 0.6 1 14 0.21<br />
K 005 - - 50 1.9 31 0.46<br />
K 010 1.5 1 0.40 1 70 1 2.6 1 66 0.97<br />
K 010 3 0.8 100 3.7 66 0.97<br />
K 015 5 1.3 150 5.6 19 0.28<br />
K 040 10 2.5 400 15 27 0.40<br />
K 080 25 6.5 800 30 55 0.81<br />
K 125 40 11 1250 45 42 0.62<br />
K 200 60 16 2000 75 85 1.25<br />
K 300 80 20 2500 90 117 1.72<br />
K 340 100 25 3400 130 166 2.44<br />
1 with titanium float<br />
INFORMATION!<br />
The operating pressure should be at least twice the pressure loss for liquids, <strong>and</strong> at least 5<br />
times the pressure loss for gases! The specified pressure drops are valid for water <strong>and</strong> air at<br />
maximum flow rate. Other flow ranges on request. Conversion of other media or operating data<br />
(pressure, temperature, density, viscosity) is performed using the calculation method in<br />
accordance with VDI /VDE Directive 3513<br />
Reference condition for gas measurements:<br />
The flow measurement of gases are refered to<br />
Nl/h or Nm 3 /h: Volume flow in Normal state 0°C, 1.013 bar abs. (DIN 1343)<br />
SCFM or SCFH: Volume flow in St<strong>and</strong>ard state 15°C, 1.013 bar abs. (ISO 13443)<br />
34<br />
www.krohne.com<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en
<strong>DK32</strong> - DK34 - DK37<br />
TECHNICAL DATA 7<br />
Valves<br />
Measuring span: 10 : 1<br />
Declaration of flow: Values = 100%<br />
Water: 20°C [68°F]<br />
Air: 20°C [68°F], 1,2 bar abs. [17.4 psia]<br />
only <strong>DK32</strong> <strong>and</strong> DK37 Max. low rate Qv Characteristic<br />
Valve spindle Water Air Kv Cv<br />
Cones Ø [mm] Ø ["] [l/h] [GPH] [Nl/h] [SCFH] [m 3 /h] [GPM]<br />
K 005 - K 010 1 0,039 5 1,32 100 3,72 0.018 0,021<br />
K 015 - K 040 - K 080 2.5 0,98 50 13,2 1000 37,2 0.15 0,175<br />
K 125 ... K 340 4.5 0,177 160 42,3 4300 160 0.48 0,552<br />
Valve characteristics<br />
Spindle 1,0mm - 0,039" Spindle 2,5mm - 0,098"<br />
Spindle 4,5mm - 0,177"<br />
1 <strong>Flow</strong>, air<br />
2 <strong>Flow</strong>, water<br />
3 Spindle rotation n<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en<br />
www.krohne.com<br />
35
7 TECHNICAL DATA<br />
<strong>DK32</strong> - DK34 - DK37<br />
7.5 Differential pressure regulators<br />
Differential pressure regulators are used (<strong>DK32</strong> <strong>and</strong> DK37 only) to help maintain constant flow<br />
rates in the case of fluctuating inlet or outlet pressures. Minimum pressure levels are required<br />
to permit operation of the regulators (see Regulator characteristics).<br />
Differential pressure regulators are not pressure reducing valves!<br />
1 Inlet pressure regulators, types RE, NRE<br />
The regulators maintain a constant flow rate at variable inlet pressure <strong>and</strong> constant outlet<br />
pressure.<br />
Example: Inlet pressure regulator RE-1000: Current flow rate: 1000l/h air<br />
Constant outlet pressure 1.013 bar abs.<br />
p2:<br />
With a variable inlet pressure greater than 0.5 bar the flow rate in the device is constant.<br />
2 Outlet pressure regulators types RA, NRA<br />
The regulators maintain a constant flow rate at constant inlet pressure <strong>and</strong> variable outlet<br />
pressure.<br />
In order to function, there must be pressure difference between the inlet pressure <strong>and</strong><br />
the outlet pressure. The inlet pressure p1 must always be greater than the outlet pressure p2.<br />
Example: Outlet pressure regulator NRA- Current flow rate:<br />
800l/h air<br />
800<br />
Constant inlet pressure: 6 bar<br />
With a variable outlet pressure of 0...5.5 bar the flowrate in the device remains constant.<br />
Regulator characteristics<br />
1 Inlet pressure regulators, types RE <strong>and</strong><br />
NRE<br />
2 Outlet pressure regulators, types RA <strong>and</strong><br />
NRA<br />
36<br />
www.krohne.com<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en
<strong>DK32</strong> - DK34 - DK37<br />
TECHNICAL DATA 7<br />
Control range<br />
Measuring span: 10 : 1<br />
Declaration of flow: Values = 100%<br />
Water: 20°C [68°F]<br />
Air: 20°C [68°F], 1,2 bar abs. [17.4 psia]<br />
Inlet pressure regulator 1<br />
Max. flowrate<br />
Water Air Min. inlet pressure<br />
[l/h] [GPH] [Nl/h] [SCFH] p1 [bar] p1 [psig]<br />
RE-1000 ...40 ...11 ...1000 ...37 0.5 7,25<br />
RE-4000 ...80 ...20 ...2000 ...75 1 14,5<br />
...100 ...25 …3000 ...110 1.5 21,8<br />
...160 ...42 ...4000 ...150 2 29<br />
NRE-100 ...2.5 ...0.6 ...100 ...3,7 0.1 1,45<br />
NRE-800 - - …250 ...9,0 0.1 1,45<br />
- - …800 ...30 0.2 2,9<br />
...25 ...6.60 - - 0.4 5,8<br />
Outlet pressure regulator 2<br />
Max. flowrate<br />
Water Air Min. pressure diff. *<br />
[l/h] [GPH] [Nl/h] [SCFH] Δp [bar] Δp [psig]<br />
RA-1000 ...40 ...11 ...1000 ...37 0,4 5,8<br />
RA-4000 ...100 ...25 …2000 ...75 1,2 17,4<br />
- - ...3000 ...110 1,2 17,4<br />
...160 ...42 ...4000 ...150 1,5 21,8<br />
NRA-800 ...1 ...0.25 ...250 ...9,0 0,05 0,73<br />
- - ...500 ...19 0,1 1,45<br />
- - …800 ...30 0,2 2,9<br />
...25 ...6.6 - - 0,4 5,8<br />
Table 7-1: * Pressure difference between inlet <strong>and</strong> outlet pressure<br />
Reference condition for gas measurements:<br />
The flow measurement of gases are refered to<br />
Nl/h or Nm 3 /h: Volume flow in Normal state 0°C, 1.013 bar abs. (DIN 1343)<br />
SCFM or SCFH: Volume flow in St<strong>and</strong>ard state 15°C, 1.013 bar abs. (ISO 13443)<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en<br />
www.krohne.com<br />
37
7 TECHNICAL DATA<br />
<strong>DK32</strong> - DK34 - DK37<br />
Technical data, differential pressure regulator<br />
St<strong>and</strong>ard connections<br />
Option<br />
Max. operating gauge pressure (at 20°C)<br />
1/4" NPT<br />
Serto, Ermeto 6 or 8, tube nozzle 6mm or 8mm, Dilo,<br />
Gyrolok, Swagelok, G 1/4<br />
64 bar / 928psig<br />
Medium temperature 150°C / 302°F<br />
Material CrNi-Steel 1.4404<br />
Gasket<br />
Membrane<br />
O-ring<br />
PTFE<br />
PTFE filled with carbon / graphite<br />
FPM<br />
other connections <strong>and</strong> materials, higher temperatures <strong>and</strong> pressures on request<br />
Dimensions with differential pressure regulators<br />
a (approx.) b (approx.) c d<br />
[mm] ["] [mm] ["] [mm] ["] [mm] ["]<br />
<strong>DK32</strong> 230 9.1 163 6.4 70 2.8 23 0.91<br />
DK37 230 9.1 200 7.9 70 2.8 23 0.91<br />
DK37/M8M 1 230 9.1 230 9.1 70 2.8 23 0.91<br />
1 with outlet pressure regulator<br />
<strong>DK32</strong> with inlet pressure regulator<br />
DK37/M8E <strong>and</strong> M8M with inlet pressure<br />
regulator<br />
<strong>DK32</strong> with outlet pressure regulator<br />
DK37/M8E with outlet pressure regulator<br />
38<br />
www.krohne.com<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en
<strong>DK32</strong> - DK34 - DK37<br />
NOTES 8<br />
01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en<br />
www.krohne.com<br />
39
KROHNE product overview<br />
© KROHNE 01/2012 - 4000287103 MA <strong>DK32</strong>-34-37-R05-en - Subject to change without notice.<br />
• Electromagnetic flowmeters<br />
• <strong>Variable</strong> area flowmeters<br />
• Ultrasonic flowmeters<br />
• Mass flowmeters<br />
• Vortex flowmeters<br />
• <strong>Flow</strong> controllers<br />
• Level meters<br />
• Temperature meters<br />
• Pressure meters<br />
• Analysis products<br />
• Measuring systems for the oil <strong>and</strong> gas industry<br />
• Measuring systems for sea-going tankers<br />