TECHNICAL INFORMATION<br />

Fix design load heading here<br />

Limit State Design Tension Load<br />

(Bond/ Concrete Capacity)<br />

80<br />

75<br />

70<br />

65<br />

60<br />

55<br />

50<br />

45<br />

40<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

M8 M10 M12 M16 M20<br />

Depth (mm) 80 90 110 125 170<br />

AC100e /<br />

KF2<br />

8.8 11.8 17.1 28.6 44.5<br />

ChemSet Injection 101 8.2 10.8 15.5 24.2 45.4<br />

Fix reference to opposition manuals here<br />

Fix Powers<br />

Image Here<br />

Fix Product<br />

name KF2 here<br />

v<br />

Fix opposition<br />

Ramset<br />

Product name<br />

here<br />

101<br />

Doc # Comp 0005<br />

Date: 27 th April 2010<br />

Limit State<br />

Fix<br />

Design<br />

design load<br />

Tension<br />

here (kN)<br />

Load (kN)<br />

In Concrete<br />

Note: Information has been extracted f<br />

rom Ramset Specifiers Resource Book 2006, page 134<br />

The <strong>information</strong> is extracted from different manufacturer's catalogues<br />

for GENERAL PURPOSE COMPARISON. It is strongly recommended<br />

to refer to the relevant technical manual/catalogue for complete<br />

product <strong>information</strong> for design of anchors and before using the product<br />

for a particular application. The load values in this chart are bond /<br />

concrete strength capacities for single anchors without spacing and /<br />

or edge distance restrictions. The steel capacity of the anchor should<br />

be checked and the anchor should be loaded with in the steel and<br />

bond/concrete strength capacity.<br />

NOTE: Information has been extracted from HILTI Australia Fastening Technology Manual Issue 2007, page 72. Ramset Specifiers Resource Book<br />

2006, page 118 and Fischer Fixing Systems Technical Handbook 06/2004, Page 222.<br />

Note<br />

The <strong>information</strong> is extracted from different manufacturer’s catalogues for GENERAL PURPOSE COMPARISON. It is strongly recommended to refer<br />

to the relevant technical manual/catalogue for complete product <strong>information</strong> for design of anchors and before using the product for a particular<br />

application. The load values in this chart are bond/concrete strength capacities for single anchors without spacing and/or edge distance restrictions.<br />

The steel capacity of the anchor should be checked and the anchor should be loaded with in the steel and bond/concrete strength capacity.<br />

Powers Fasteners Technical Information Booklet I 98