Powers Fasteners<br />

Note<br />

Limit State<br />

Fix design load<br />

Design<br />

heading here<br />

Tension Load<br />

(Bond/ Concrete Capacity)<br />

150<br />

Fix Powers<br />

Image Here<br />

PF PRO<br />

125<br />

V12<br />

100<br />

vs<br />

Ramset<br />

Chemset Reo 502<br />

VS<br />

Ramset<br />

Chemset Injection<br />

801<br />

75<br />

Doc # Comp 0018<br />

Date: 10 th May 2011<br />

50<br />

In 32 MPa Concrete<br />

25<br />

Limit State Design Tension Load (kN)<br />

0<br />

The <strong>information</strong> is extracted from different manufacturer's catalogues<br />

for GENERAL PURPOSE COMPARISON. It is strongly recommended<br />

to refer to the relevant technical manual/catalogue for complete<br />

product <strong>information</strong> for design of anchors and before using the product<br />

for a particular application. The load values in this chart are bond /<br />

concrete strength capacities for single anchors without spacing and /<br />

or edge distance restrictions. The steel capacity of the anchor should<br />

be checked and the anchor should be loaded with in the steel and<br />

bond/concrete strength capacity.<br />

NOTE: Information has been extracted from HILTI Australia Fastening Technology Manual Issue 2007, page 72. Ramset Specifiers Resource Book<br />

2006, page 118 and Fischer Fixing Systems Technical Handbook 06/2004, Page 222.<br />

The <strong>information</strong> is extracted from different manufacturer’s catalogues for GENERAL PURPOSE COMPARISON. It is strongly recommended to refer<br />

to the relevant technical manual/catalogue for complete product <strong>information</strong> for design of anchors and before using the product for a particular<br />

application. The load values in this chart are bond/concrete strength capacities for single anchors without spacing and/or edge distance restrictions.<br />

The steel capacity of the anchor should be checked and the anchor should be loaded with in the steel and bond/concrete strength capacity.<br />

M8 M10 M12 M16 M20 M24<br />

Depth (mm) 80 90 110 125 170 210<br />

PFPRO 17.0 25.0 40.8 57.8 98.3 139.2<br />

V12 12.6 21.3 31.3 47.4 80.6 109.5<br />

Chemset Reo 502 11.4 23.5 34.2 54.7 77.4 96.5<br />

Chemset Injection 801 13.7 17.8 25.9 35.2 61.1 90.2<br />

Notes:<br />

Information has been extracted from Ramset Specifiers Resource Book 2006 (pages 118, 126) and Powers Fasteners Adhesive<br />

Technical Manuals.<br />

V12 should not be used in diamond core drilled holes.<br />

20 21 I <strong>Parchem</strong> Construction Supplies Pty Ltd (ABN 80 069 961 968)