TECHNICAL INFORMATION<br />

70.0<br />

60.0<br />

Fix Powers<br />

Image Here<br />

Vs<br />

Hilti HIT-HY 150<br />

Vs<br />

Note<br />

Working<br />

Fix<br />

Stress<br />

design load heading<br />

Design<br />

here<br />

Tension Load<br />

Ramset<br />

Structaset 401<br />

(Bond/ Concrete Capacity in 32MPa Concrete)<br />

V12<br />

Vs<br />

Ramset<br />

Chemset 101<br />

Doc # Comp 0012<br />

Date: 04 th Feb 2010<br />

50.0<br />

40.0<br />

30.0<br />

Tension Load (kN)<br />

20.0<br />

Working Stress Design<br />

10.0<br />

0.0<br />

M8 M10 M12 M16 M20 M24<br />

The <strong>information</strong> is extracted from different manufacturer's catalogues<br />

for GENERAL PURPOSE COMPARISON. It is strongly recommended<br />

to refer to the relevant technical manual/catalogue for complete<br />

product <strong>information</strong> for design of anchors and before using the product<br />

for a particular application. The load values in this chart are bond /<br />

concrete strength capacities for single anchors without spacing and /<br />

or edge distance restrictions. The steel capacity of the anchor should<br />

be checked and the anchor should be loaded with in the steel and<br />

bond/concrete strength capacity.<br />

NOTE: Information has been extracted from HILTI Australia Fastening Technology Manual Issue 2007, page 72. Ramset Specifiers Resource Book<br />

2006, page 118 and Fischer Fixing Systems Technical Handbook 06/2004, Page 222.<br />

The <strong>information</strong> is extracted from different manufacturer’s catalogues for GENERAL PURPOSE COMPARISON. It is strongly recommended to refer<br />

to the relevant technical manual/catalogue for complete product <strong>information</strong> for design of anchors and before using the product for a particular<br />

application. The load values in this chart are bond/concrete strength capacities for single anchors without spacing and/or edge distance restrictions.<br />

The steel capacity of the anchor should be checked and the anchor should be loaded with in the steel and bond/concrete strength capacity.<br />

Depth (mm) 80 90 110 125 170 210<br />

V12 7.0 11.9 17.4 26.3 44.8 60.8<br />

Structaset 401 6.5 10.1 15.3 20.8 27.7 43.3<br />

HIT-HY 150 6.9 9.2 13.8 17.6 29.9 37.3<br />

Chemset 101 4.5 6.0 8.6 13.5 25.2 42.9<br />

Note: Information has been extracted from Ramset Specifiers Resource Book 2006 and Structaset401 manual downloaded from<br />

internet, HILTI Fastening Technology Manual 2007 (p81 & 86).<br />

Powers Fasteners Technical Information Booklet I 17 16