TECHNICAL INFORMATION<br />
Note<br />
Limit State<br />
Fix design load<br />
Design<br />
heading here<br />
Tension Load<br />
Fix Powers<br />
Image Here<br />
(Bond/ Concrete Capacity)<br />
Fix Product<br />
PF PRO<br />
name here<br />
150<br />
125<br />
100<br />
75<br />
v<br />
Hilti<br />
HIT-HY 150<br />
Doc # Comp 0010<br />
Date: 24 th JAN 2010<br />
In Concrete<br />
50<br />
25<br />
Limit State Design Tension Load (kN)<br />
The <strong>information</strong> is extracted from different manufacturer's catalogues<br />
for GENERAL PURPOSE COMPARISON. It is strongly recommended<br />
to refer to the relevant technical manual/catalogue for complete<br />
product <strong>information</strong> for design of anchors and before using the product<br />
for a particular application. The load values in this chart are bond /<br />
concrete strength capacities for single anchors without spacing and /<br />
or edge distance restrictions. The steel capacity of the anchor should<br />
be checked and the anchor should be loaded with in the steel and<br />
bond/concrete strength capacity.<br />
0<br />
M8 M10 M12 M16 M20 M24<br />
Depth (mm) 80 90 110 125 170 210<br />
PFPRO 17.0 25.0 40.8 57.8 98.3 139.2<br />
HIT-HY 150 with HAS 9.7 12.9 19.3 24.6 41.9 52.2<br />
Rod<br />
NOTE: Information has been extracted from HILTI Australia Fastening Technology Manual Issue 2007, page 72. Ramset Specifiers Resource Book<br />
2006, page 118 and Fischer Fixing Systems Technical Handbook 06/2004, Page 222.<br />
The <strong>information</strong> is extracted from different manufacturer’s catalogues for GENERAL PURPOSE COMPARISON. It is strongly recommended to refer<br />
to the relevant technical manual/catalogue for complete product <strong>information</strong> for design of anchors and before using the product for a particular<br />
application. The load values in this chart are bond/concrete strength capacities for single anchors without spacing and/or edge distance restrictions.<br />
The steel capacity of the anchor should be checked and the anchor should be loaded with in the steel and bond/concrete strength capacity.<br />
Note: Information has been extracted from HILTI Australia Fastening Technology Manual Issue 2007, page 81, and Hilti international<br />
<strong>information</strong> (internet version).<br />
Powers Fasteners Technical Information Booklet I 15 14