TECHNICAL INFORMATION<br />
140<br />
130<br />
120<br />
110<br />
100<br />
90<br />
80<br />
70<br />
60<br />
Limit State Design Tension Load<br />
(Bond/ Concrete Capacity)<br />
Fix Powers<br />
Image Here<br />
PFPRO<br />
v<br />
AC100PRO<br />
v<br />
Limit State Design Tension Load (kN)<br />
Fix design load here (kN)<br />
In Concrete<br />
50<br />
40<br />
30<br />
20<br />
10<br />
0<br />
M8 M10 M12 M16 M20 M24<br />
Depth (mm) 80 90 110 125 170 210<br />
PFPRO 17.0 25.0 40.8 57.8 98.3 139.2<br />
AC100PRO 12.6 18.2 26.5 37.9 55.5 68.7<br />
KF2 8.8 11.8 17.1 28.6 44.5 64.1<br />
Note<br />
AC100e 8.8 11.8 17.1 28.6 44.5 64.1<br />
Note: Information has been extracted from Powers Fasteners’ Adhesive Anchoring<br />
Systems Design Manual 2009.<br />
KF2 &<br />
AC100e<br />
Doc # Comp 0009<br />
Date: 26 th August 2010<br />
The <strong>information</strong> is extracted from the Adhesive Anchoring Systems<br />
Design Manual 2009 for GENERAL PURPOSE COMPARISON. It is<br />
strongly recommended to refer to the relevant technical<br />
manual/catalogue for complete product <strong>information</strong> for design of<br />
anchors and before using the product for a particular application. The<br />
load values in this chart are bond / concrete strength capacities for<br />
single anchors without spacing and / or edge distance restrictions. The<br />
steel capacity of the anchor should be checked and the anchor should<br />
be loaded with in the steel and bond/concrete strength capacity.<br />
NOTE: Information has been extracted from HILTI Australia Fastening Technology Manual Issue 2007, page 72. Ramset Specifiers Resource Book<br />
2006, page 118 and Fischer Fixing Systems Technical Handbook 06/2004, Page 222.<br />
The <strong>information</strong> is extracted from different manufacturer’s catalogues for GENERAL PURPOSE COMPARISON. It is strongly recommended to refer<br />
to the relevant technical manual/catalogue for complete product <strong>information</strong> for design of anchors and before using the product for a particular<br />
application. The load values in this chart are bond/concrete strength capacities for single anchors without spacing and/or edge distance restrictions.<br />
The steel capacity of the anchor should be checked and the anchor should be loaded with in the steel and bond/concrete strength capacity.<br />
Powers Fasteners Technical Information Booklet I 13 12