Crocus SHDSL Repeater 2P - Route 66 Communications
Crocus SHDSL Repeater 2P - Route 66 Communications Crocus SHDSL Repeater 2P - Route 66 Communications
50 Crocus SHDSL Repeater 2P Chapter 5 User manual Technical specifications 5.5 Outdoor Crocus SHDSL Repeater 2P IP67 signal connector lay-out The following figure shows a front and top view of the IP67 signal connector of the outdoor Crocus SHDSL Repeater 2P: The following table gives the pin lay-out of the IP67 signal connector: Signal group Pin Signal line NE E7 channel A, tip E8 E3 E4 channel A, ring channel B, tip channel B, ring line FE D7 channel A, tip D8 D3 D4 channel A, ring channel B, tip channel B, ring monitor D5 RxD functional protective earth D1 D6 E5 E6 TxD SGND FPE FPE
Crocus SHDSL Repeater 2P Chapter 5 51 User manual Technical specifications 5.6 Jumper settings This section shows the mandatory jumper settings for the Crocus SHDSL Repeater 2P. The following picture shows the top and bottom Crocus SHDSL Repeater 2P PCBs as they are assembled:
- Page 7 and 8: Crocus SHDSL Repeater 2P User manua
- Page 9 and 10: Crocus SHDSL Repeater 2P 1 User man
- Page 11 and 12: Crocus SHDSL Repeater 2P Chapter 1
- Page 13 and 14: Crocus SHDSL Repeater 2P Chapter 1
- Page 15 and 16: Crocus SHDSL Repeater 2P Chapter 1
- Page 17 and 18: Crocus SHDSL Repeater 2P Chapter 2
- Page 19 and 20: Crocus SHDSL Repeater 2P Chapter 2
- Page 21 and 22: Crocus SHDSL Repeater 2P Chapter 2
- Page 23 and 24: Crocus SHDSL Repeater 2P Chapter 2
- Page 25 and 26: Crocus SHDSL Repeater 2P Chapter 2
- Page 27 and 28: Crocus SHDSL Repeater 2P Chapter 2
- Page 29 and 30: Crocus SHDSL Repeater 2P Chapter 2
- Page 31 and 32: Crocus SHDSL Repeater 2P Chapter 2
- Page 33 and 34: Crocus SHDSL Repeater 2P Chapter 2
- Page 35 and 36: Crocus SHDSL Repeater 2P Chapter 2
- Page 37 and 38: Crocus SHDSL Repeater 2P Chapter 3
- Page 39 and 40: Crocus SHDSL Repeater 2P Chapter 3
- Page 41 and 42: Crocus SHDSL Repeater 2P Chapter 3
- Page 43 and 44: Crocus SHDSL Repeater 2P Chapter 3
- Page 45 and 46: Crocus SHDSL Repeater 2P Chapter 4
- Page 47 and 48: Crocus SHDSL Repeater 2P Chapter 4
- Page 49 and 50: Crocus SHDSL Repeater 2P Chapter 4
- Page 51 and 52: Crocus SHDSL Repeater 2P Chapter 4
- Page 53 and 54: Crocus SHDSL Repeater 2P Chapter 4
- Page 55 and 56: Crocus SHDSL Repeater 2P Chapter 5
- Page 57: Crocus SHDSL Repeater 2P Chapter 5
- Page 61 and 62: Crocus SHDSL Repeater 2P Chapter 5
- Page 63 and 64: Crocus SHDSL Repeater 2P Chapter 5
- Page 65 and 66: Crocus SHDSL Repeater 2P 57 Annex A
- Page 67 and 68: Crocus SHDSL Repeater 2P Annex A: 5
- Page 69 and 70: Crocus SHDSL Repeater 2P Annex Inde
50 <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong> Chapter 5<br />
User manual<br />
Technical specifications<br />
5.5 Outdoor <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong> IP67 signal connector<br />
lay-out<br />
The following figure shows a front and top view of the IP67 signal connector of the outdoor <strong>Crocus</strong><br />
<strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong>:<br />
The following table gives the pin lay-out of the IP67 signal connector:<br />
Signal group Pin Signal<br />
line NE E7 channel A, tip<br />
E8<br />
E3<br />
E4<br />
channel A, ring<br />
channel B, tip<br />
channel B, ring<br />
line FE D7 channel A, tip<br />
D8<br />
D3<br />
D4<br />
channel A, ring<br />
channel B, tip<br />
channel B, ring<br />
monitor D5 RxD<br />
functional protective<br />
earth<br />
D1<br />
D6<br />
E5<br />
E6<br />
TxD<br />
SGND<br />
FPE<br />
FPE