<strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong> Chapter 5 49<br />
User manual<br />
Technical specifications<br />
5.3 Monitor interface specifications<br />
• Applicable standards: EIA-232 / V.28<br />
• Connector:<br />
- Indoor version: female DB9 on back panel<br />
- Outdoor version: monitor pins on the IP67 signal connector<br />
• Data rate: 9600 baud, asynchronous<br />
• Protocol: 8 bit, no parity, 1 stop bit, no line feed with carriage return, XON/XOFF enabled<br />
• Signal level: V.28<br />
5.4 Monitor connector lay-out<br />
The monitor connector lay-out is as follows:<br />
Pin Signal Description DCE Figure<br />
1 SGND EIA-232 Signal<br />
Ground<br />
2 RxD EIA-232 Receive<br />
Data<br />
3 TxD EIA-232 Transmit<br />
Data<br />
Signal Ground<br />
output<br />
input<br />
4 - not used -<br />
5 SGND EIA-232 Signal<br />
Ground<br />
Signal Ground<br />
6 - not used -<br />
7 - not used -<br />
8 - not used -<br />
9 - not used -