Crocus SHDSL Repeater 2P - Route 66 Communications

Crocus SHDSL Repeater 2P - Route 66 Communications Crocus SHDSL Repeater 2P - Route 66 Communications

route66com.com
from route66com.com More from this publisher
06.04.2014 Views

46 Crocus SHDSL Repeater 2P Chapter 4 User manual Monitor interface BASERATE This command sets respectively the N-side and C-side to a fixed line rate. It sets the amount of available 64 kbps channels. Enter a value between 16 and 32 (i.e. a range from 1024 kbps up to 2048 kbps). In order to optimise the bandwidth of your connection, set the base rate to the highest possible value which gives a stable connection. • Syntax: BASERATE [N,N] • Example: BASERATE 20,20 ADAPTIVE This command sets respectively the N-side and C-side to adaptive line rate mode. In this case, the Crocus SHDSL Repeater 2P tries to achieve the highest possible line rate which gives a stable connection. • Syntax: ADAPTIVE [ON|OFF,ON|OFF] • Example: ADAPTIVE ON,ON ID This command sets the unique identification string which is displayed in the main menu. • Syntax: ID [TEXT] • Example: ID MyShdslRepeater

Crocus SHDSL Repeater 2P Chapter 5 47 User manual Technical specifications 5 Technical specifications This chapter gives the technical specifications of the Crocus SHDSL Repeater 2P. The following gives an overview of this chapter: • 5.1 - Line specifications on page 48 • 5.2 - Line connector lay-out on page 48 • 5.3 - Monitor interface specifications on page 49 • 5.4 - Monitor connector lay-out on page 49 • 5.5 - Outdoor Crocus SHDSL Repeater 2P IP67 signal connector lay-out on page 50 • 5.6 - Jumper settings on page 51 • 5.7 - Power requirements on page 54 • 5.8 - Power connector lay-out on page 54 • 5.9 - Dimensions on page 55 • 5.10 - Safety compliance on page 55 • 5.11 - Over-voltage and over-current protection compliance on page 55 • 5.12 - EMC compliance on page 55 • 5.13 - Environmental compliance on page 56

<strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong> Chapter 5 47<br />

User manual<br />

Technical specifications<br />

5 Technical specifications<br />

This chapter gives the technical specifications of the <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong>. The following gives<br />

an overview of this chapter:<br />

• 5.1 - Line specifications on page 48<br />

• 5.2 - Line connector lay-out on page 48<br />

• 5.3 - Monitor interface specifications on page 49<br />

• 5.4 - Monitor connector lay-out on page 49<br />

• 5.5 - Outdoor <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong> IP67 signal connector lay-out on page 50<br />

• 5.6 - Jumper settings on page 51<br />

• 5.7 - Power requirements on page 54<br />

• 5.8 - Power connector lay-out on page 54<br />

• 5.9 - Dimensions on page 55<br />

• 5.10 - Safety compliance on page 55<br />

• 5.11 - Over-voltage and over-current protection compliance on page 55<br />

• 5.12 - EMC compliance on page 55<br />

• 5.13 - Environmental compliance on page 56