46 <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong> Chapter 4<br />
User manual<br />
Monitor interface<br />
BASERATE<br />
This command sets respectively the N-side and C-side to a fixed line rate. It sets the amount of available<br />
64 kbps channels. Enter a value between 16 and 32 (i.e. a range from 1024 kbps up to 2048 kbps).<br />
In order to optimise the bandwidth of your connection, set the base rate to the highest possible value<br />
which gives a stable connection.<br />
• Syntax: BASERATE [N,N]<br />
• Example: BASERATE 20,20<br />
ADAPTIVE<br />
This command sets respectively the N-side and C-side to adaptive line rate mode. In this case, the <strong>Crocus</strong><br />
<strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong> tries to achieve the highest possible line rate which gives a stable connection.<br />
• Syntax: ADAPTIVE [ON|OFF,ON|OFF]<br />
• Example: ADAPTIVE ON,ON<br />
ID<br />
This command sets the unique identification string which is displayed in the main menu.<br />
• Syntax: ID [TEXT]<br />
• Example: ID MyShdsl<strong>Repeater</strong>