30 <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong> Chapter 3<br />

User manual<br />

Basic operation<br />

3.1 Connecting the NE side and FE side<br />

When you set up an <strong>SHDSL</strong> link, the central <strong>SHDSL</strong> device has to be master and the remote <strong>SHDSL</strong><br />

device has to be the slave (e.g. refer to the configuration attribute ”channel“ on the <strong>Crocus</strong> <strong>SHDSL</strong><br />

modem).<br />

The <strong>SHDSL</strong> interface of the <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong> consists of two “sides”:<br />

<strong>SHDSL</strong> interface<br />

side<br />

NE side<br />

FE side<br />

Description<br />

This side operates in slave mode and has to be connected to the central<br />

<strong>SHDSL</strong> device.<br />

If there is more than one repeater in the link, then the NE side of one repeater<br />

has to be connected to the FE side of the other repeater.<br />

This side operates in master mode and has to be connected to the remote<br />

<strong>SHDSL</strong> device.<br />

If there is more than one repeater in the link, then the FE side of one repeater<br />

has to be connected to the NE side of the other repeater.<br />

In case of the …<br />

• indoor <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong>, refer to 5.2 - Line connector lay-out on page 48 to find out which<br />

RJ45 connector is the NE connector and which the FE connector.<br />

• outdoor <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong>, refer to 5.5 - Outdoor <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong> IP67 signal<br />

connector lay-out on page 50 to find out which pins of the signal connector are the NE side and which<br />

the FE side.<br />

The following figure shows an example on how to connect the NE side and the FE side of the <strong>Crocus</strong><br />

<strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong>: