06.04.2014 Views

Crocus SHDSL Repeater 2P - Route 66 Communications

Crocus SHDSL Repeater 2P - Route 66 Communications

Crocus SHDSL Repeater 2P - Route 66 Communications

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

20 <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong> Chapter 2<br />

User manual<br />

Installing and connecting the <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong><br />

Wiring the male IP67 signal plug<br />

To attach the male IP67 signal plug to the cable, proceed as follows:<br />

Step<br />

Action<br />

1 Unscrew the 4 screws (2) that attach the connector block to the connector housing.<br />

2 Take the connector block (1) out of the connector housing (3).<br />

3 Unscrew the nut (6).<br />

4 Remove the IP67 plate (5).<br />

5 Slide the cable through the nut (6) and the wire transit (4) into the connector housing (3).<br />

6 Wire the cable to the connector block (1). Refer to 5.5 - Outdoor <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong><br />

<strong>2P</strong> IP67 signal connector lay-out on page 50.<br />

7 Put the connector block (1) back into the connector housing and tighten the screws (2).<br />

8 If the diameter of the cable is not big enough to seal the opening of the wire transit (4)<br />

air- and watertight, then use the high temperature silicone paste (delivered with the outdoor<br />

<strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong>) to glue the cable into the wire transit (4). This will<br />

ensure the IP67 quality. Proceed as follows:<br />

1. Apply the high temperature silicone paste as indicated in the figure below.<br />

2. Slide the nut over the wire transit.<br />

3. Tighten the nut.<br />

9 Tighten the nut (6). This nut ensures the IP67 quality.<br />

10 Now plug the male IP67 signal plug you just wired into the female IP67 signal connector.<br />

Refer to 2.6.1 - Parts of the outdoor <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong> on page 16.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!