20 <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong> Chapter 2<br />
User manual<br />
Installing and connecting the <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong><br />
Wiring the male IP67 signal plug<br />
To attach the male IP67 signal plug to the cable, proceed as follows:<br />
Step<br />
Action<br />
1 Unscrew the 4 screws (2) that attach the connector block to the connector housing.<br />
2 Take the connector block (1) out of the connector housing (3).<br />
3 Unscrew the nut (6).<br />
4 Remove the IP67 plate (5).<br />
5 Slide the cable through the nut (6) and the wire transit (4) into the connector housing (3).<br />
6 Wire the cable to the connector block (1). Refer to 5.5 - Outdoor <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong><br />
<strong>2P</strong> IP67 signal connector lay-out on page 50.<br />
7 Put the connector block (1) back into the connector housing and tighten the screws (2).<br />
8 If the diameter of the cable is not big enough to seal the opening of the wire transit (4)<br />
air- and watertight, then use the high temperature silicone paste (delivered with the outdoor<br />
<strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong>) to glue the cable into the wire transit (4). This will<br />
ensure the IP67 quality. Proceed as follows:<br />
1. Apply the high temperature silicone paste as indicated in the figure below.<br />
2. Slide the nut over the wire transit.<br />
3. Tighten the nut.<br />
9 Tighten the nut (6). This nut ensures the IP67 quality.<br />
10 Now plug the male IP67 signal plug you just wired into the female IP67 signal connector.<br />
Refer to 2.6.1 - Parts of the outdoor <strong>Crocus</strong> <strong>SHDSL</strong> <strong>Repeater</strong> <strong>2P</strong> on page 16.